Interference phenomenon that often occurs in LS power inverters

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;

2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter;

3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;

4. The voltage transformer (4-20mA) jumps randomly after the LS inverter is started, while the nearby integrated thermal resistance (4-20mA) is not affected, and the signal lines are not shielded;

                                 Interference phenomenon that often occurs in LS power inverters

These phenomena are due to the disturbance of LS inverters. So why do drives cause disturbance? First of all, we all know that the frequency converter is used to change the frequency. The inverter includes a rectifier circuit and an inverter circuit, and the input alternating current is converted into DC voltage through the rectifier circuit and flat-wave circuit, and then the DC voltage is converted into pulse voltage of different widths (called pulse width modulation voltage, PWM) through the inverter. By using this PWM voltage to drive the motor, the motor torque and speed can be adjusted.

More on that
LS static test to determine the fault of the inverter LS static test to determine the fault of the inverter

Generally, the general-purpose inverter roughly includes the following parts: (1) rectifier circuit; (2) DC central circuit; (3) Inverter circuit; (4) Control circuit. The static test is mainly a test of the high-power transistors (power modules) of the rectifier circuit, DC center circuit and inverter circuit. Whole...

What are the categories of PLC products? What are the categories of PLC products?

The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...

How does the interference of the frequency converter occur? -- Electricity production How does the interference of the frequency converter occur? -- Electricity production

To discuss the disturbance problem of LS inverter, we must first understand the operating principle of inverter, from the structural point of view, inverter is divided into direct inverter and direct inverter. The direct inverter is a communication that directly converts the I frequency current into a controllable frequency, and there is no intermediate DC link. Each phase of it ...

Inverter exception handling method - LS power generation Inverter exception handling method - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working properly; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

Briefly describe LS ABE203b molded case circuit breaker Briefly describe LS ABE203b molded case circuit breaker

The circuit breaker is a fundamental low-voltage electrical appliance, which has the function of overload, short circuit and undervoltage maintenance, and has the ability to maintain the line and power supply. Circuit breaker is an indispensable product in electrical safety. Due to different applications, there are molded case circuit breakers, frame circuit breakers, miniature circuit breakers, etc.

Analysis of the problem of LS power inverter Analysis of the problem of LS power inverter

1. What is the maintenance function of the inverter? Maintenance functions can be divided into the following two categories: (1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance. (2) Block the PWM control signal of power semiconductor equipment after detecting the abnormality ...

The reason for the overload trip of the inverter - LS generates electricity The reason for the overload trip of the inverter - LS generates electricity

1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor. 2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.

Motor & Electrical Control Technology Tips - LS Electricity Production Motor & Electrical Control Technology Tips - LS Electricity Production

1. Low-voltage electrical appliances: refers to electrical appliances that play the role of on-off, maintenance, control or regulation in circuits with a rated voltage of 1200V and a rated voltage of 1500V and below. 2. Main electrical appliances: electrical appliances used to send control instructions in the automatic control system. 3. Fuse: ...

The selection principle of AC contactors - LS produces electricity The selection principle of AC contactors - LS produces electricity

1. The voltage level of the AC contactor should be the same as the load, and the type of contactor should be suitable for the load. 2. The accounting current of the load should be less than or equal to the additional working current of the contactor. The turn-on current of the contactor is greater than the starting current of the load, and the breaking current is greater than the load ...

Introduction to vector control of inverter and motor - LS power generation Introduction to vector control of inverter and motor - LS power generation

As for the use of vector-operated motors, it can be divided into two categories, namely non-reactive vector control (SVC) and reactive vector control (FVC). Vectorless Handling (SVC): Due to the speed response, additional equipment for the encoder is installed in the motor dragged by the inverter, which is cumbersome. Here...

Precautions for inverter installation tips - LS power generation Precautions for inverter installation tips - LS power generation

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transients caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Introduction to LS Master-K series PLC programming Introduction to LS Master-K series PLC programming

LS is an electrical equipment company affiliated to LG, kglwin3.62 programming software Chinese version is a professional plc programming software designed to help daily more efficient planning and development software, the software supports the programming and debugging of LG Master-K series and LG MASTER-K series, and provides ...

Variable frequency regenerative braking method - LS generates electricity Variable frequency regenerative braking method - LS generates electricity

1. Energy consumption type This method is to connect a braking resistor in parallel in the DC circuit of the inverter, and control the on/off of a power tube by detecting the DC bus voltage. When the DC bus voltage rises to about 700V, the power tube is turned on, and the regenerative energy is passed into the resistor.

The reason why the inverter cannot be equipped with a leakage protector The reason why the inverter cannot be equipped with a leakage protector

When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together, the leakage maintainer acts, and the system foundation cannot be ...

Introduction of plc inverter - LS power generation Introduction of plc inverter - LS power generation

Because the imported products of the inverter brand have their own PLC function, they mainly play an important role in the control effect of mechanical equipment, and play an important role in the equipment, which can regulate the operation and control of the machine and meet the requirements of users. It should be scale pLC ...

What is the difference between LS inverter and LG inverter? What is the difference between LS inverter and LG inverter?

LS inverter and LG inverter are the same, there is no difference between the two. LS inverter, the full name of LS AC inverter governor, after supplying a variety of configurations, converts direct current into communication power, and changes the general power supply ...

Inverter external potentiometer connection method - LS power generation Inverter external potentiometer connection method - LS power generation

The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the height may reach 630A. L ...

Analysis of the fault problem of LS power terminal block Analysis of the fault problem of LS power terminal block

From the point of view of application, the function of the terminal block should be achieved: it is necessary to conduct the local conduction of the touch part, and the touch is reliable. The insulating part should not be conducted, and it is necessary to insulate it firmly. There are three common forms of fatal problems in terminal blocks: ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top