Introduction of LS AC motors

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. AC synchronous motor: that is, the rotor is composed of permanent magnet data, so after rolling, with the change of the stator rotation magnetic field of the motor, the rotor also changes the speed of the response frequency, and the rotor speed = stator speed, so it is called "synchronization".

                                 Introduction of LS AC motors

2. AC asynchronous motor: The rotor is composed of an induction coil and data. After rolling, the stator produces a rotating magnetic field, the magnetic field cuts the induction coil of the rotor, the rotor coil produces an induced current, so that the rotor produces an induced magnetic field, and the induced magnetic field follows the change of the rotating magnetic field of the stator, but the magnetic field change of the rotor is permanently smaller than the change of the stator, once it is equal to the magnetic field that has not changed cuts the induction coil of the rotor, there is no induced current in the rotor coil, the rotor magnetic field disappears, and the rotor stalls and the stator produces a speed difference and the sense of response current again. Therefore, in the communication asynchronous motor, there is a key parameter is the slip rate, which is the ratio of the speed difference between the rotor and the stator.

3. The corresponding AC synchronous and asynchronous motors have corresponding synchronous inverters and asynchronous inverters, and the servo motors also have AC synchronous servos and AC asynchronous servos.

More on that
The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

The reason why the inverter cannot be equipped with a leakage protector The reason why the inverter cannot be equipped with a leakage protector

When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together, the leakage maintainer acts, and the system foundation cannot be ...

The difference between servo drive and frequency converter - LS produces electricity The difference between servo drive and frequency converter - LS produces electricity

Servo drives and frequency converters are defined differently The driver, also known as servo manipulator and servo amplifier, is a kind of manipulator used to control servo motors, and its function is similar to that of a frequency converter acting on a general communication motor. It is part of the servo system, mainly used for high-precision positioning ...

The difference between inverter and power saver - LS produces electricity The difference between inverter and power saver - LS produces electricity

First, the frequency conversion skill is only one of the many power-saving skills, including voltage regulation and current limiting, power factor compensation, phased power regulation, frequency conversion, chopping, filtering, energy feedback and other skills, even if the power saver using the principle of frequency conversion is concerned, the frequency converter is only power-saving.

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

Types and characteristics of PLC digital output modules for power production Types and characteristics of PLC digital output modules for power production

  The main functions and functions of PLC: 1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...

Inverter fault diagnosis - LS power generation Inverter fault diagnosis - LS power generation

1. How to distinguish between heavy and light faults When there is a problem with the light, the system announces the alarm signal and the fault indicator flashes. When there is a serious problem, the system will announce the problem indicator, the problem indicator will always be on, together announce the order to break the high voltage and stop closing, and store the problem ...

DC reactor for inverter and design calculation - LS power generation DC reactor for inverter and design calculation - LS power generation

The DC reactor for the inverter is also called the flat wave reactor, which is connected in series in the DC bus (terminals P1 and P+). The main thing is to reduce the higher harmonic component of the input current and improve the power factor of the input power supply (to 0.95). This reactor can be used at the same time as the AC reactor, and the inverter has high power ...

The difference between overload and overcurrent of the inverter The difference between overload and overcurrent of the inverter

(1) The maintenance objectives are different Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded. ...

What are the categories of PLC products? What are the categories of PLC products?

The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...

Distinguish between good and bad inverters - LS produces electricity Distinguish between good and bad inverters - LS produces electricity

The quality of a thing is relatively speaking, the inverter as a power supply used to drive the motor to run, its function is to regulate the speed, under the premise of normal wiring, reasonable parameters, and no fault with the load, if the speed of the motor can be controlled according to the requirements, the shaking error is less than the equipment ...

LS power production contactors are used in this area LS power production contactors are used in this area

LS contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in electricity, power distribution and consumption. Contactor in a broad sense refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field and close the contact to control the load in industrial electricity. ...

LS electric braking unit functions, advantages and operation process LS electric braking unit functions, advantages and operation process

First, the main function of the braking unit In some applications, the need for rapid speed reduction, according to the principle of asynchronous motor, it can be known that if the slip is larger, the greater the torque, the same braking torque will increase with the increase of the speed reduction rate, so that the system speed reduction time is greatly shortened, and the energy feedback is greatly ...

Debugging of basic parameters of inverter - LS power generation Debugging of basic parameters of inverter - LS power generation

There are many functional parameters of the inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to set and debug every parameter, and most of them only need to use the factory setting value. However, some parameters are very closely related to the application of practice, and some of them are still ...

The basic problem of LS electric molded case circuit breaker The basic problem of LS electric molded case circuit breaker

Rated current of LS molded case circuit breaker: Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...

Characteristics of single-phase current converter - LS power generation Characteristics of single-phase current converter - LS power generation

Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The selection of advanced filtering technology, reasonable software algorithms, processing ...

Introduction to the output frequency of the inverter - LS power generation Introduction to the output frequency of the inverter - LS power generation

1. Maximum frequency fmax, reference frequency fN and reference voltage UN 2. The upper frequency fH and the lower frequency fL The output frequency of the inverter is limited to the upper and lower limit frequencies to prevent errors in the event of misoperation. 3. Frequency of activation When the signal ON is activated, the ON ...

Introduction of LS PLC programming software Introduction of LS PLC programming software

LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.

Common practical knowledge in the inverter industry - power inverter Common practical knowledge in the inverter industry - power inverter

The inverter is the power frequency power supply (50Hz or 60Hz) converted into various frequencies of AC power supply to achieve the variable speed operation of the motor equipment, by changing the motor power frequency to achieve speed adjustment, is an ideal high-efficiency, high-speed regulation means. Frequency converters are used in industrial production and residential ...

Selection principles and key points of AC contactors for power production Selection principles and key points of AC contactors for power production

1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage. 2. The operating frequency of the motor is not high, such as compressor, water pump, air ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top