There are three main differences, namely: different applications, different products, and different characteristics.
1. The application is different: the programmable manipulator produced by Siemens in Germany is also widely used in China, and is used in metallurgy, chemical industry, printing production line and other fields; Schneider PLCs can be used in Unity Pro and can be integrated into a standard HMI/SCADA system for supervising and manipulating SFC programs.
2. Different products: Siemens' PLC products include LOGO, S7-200, S7-1200, S7-300, S7-400, S7-1500, etc.; Schneider PLC mainly includes Quantum, Compact (discontinued), Momentum and other series under the original Modicon.
3. Different characteristics: Siemens S7 series PLC is small in size, fast in speed, standardized, has network communication capabilities, stronger functions and high reliability; Schneider PLC's new innovative design shortens the development time, and the flexibility of the processor enables higher performance. Based on openness and the synergistic use of tools, it prioritizes productivity improvements.
|
More on that
|
Schneider Electric miniature circuit breaker accident prevention
With the development of the electric power industry, now the electricity has been accompanied by every detail of our days, so the maintenance of the electric power industry, began to get more and more attention from everyone, because the circuit in the daily operation side, very simple because of overvoltage or undervoltage and present a certain problem, which ...
|
|
The 7 peripherals of the inverter governor - Schneider
1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...
|
|
Schneider launches the new ComPacT NSX molded case circuit breaker
From August 23 to 25, 2021, the 2021 China World Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing World Expo Center. Mitsubishi Electric (China) ...
|
|
Schneider Instrumentation Classification Standard
The classification specifications for the appearance of the instrument are as follows:
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...
|
|
Schneider introduces the new Lexium28S servo
The newly launched Lexium28S Sercos III bus servo with BCH2 servo motor is available as a pre-order product portfolio to meet the needs of motion control and optimize the function of the machine. Lexium28S servo drives, available in 4 sizes, 10 models, power mask 0.05KW to 4 ...
|
|
Schneider selection of different types of circuit breakers
Miniature circuit breakers are: A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc.
Molded case circuit breakers are: NSX, NSE, EZD, NSC, large molded case NS.
Structural circuit breakers include: MT, MTE, etc.
...
|
|
Detailed explanation of the steps of Schneider inverter inverter setup
1. Macro equipment:
In view of the control requirements of different loads, Schneider inverters have talked about the macro equipment in advance and the initial function of the I/O terminals.
Changes to the macro rig can be corrected under the Abbreviated Boot Menu.
If required, it is also possible to re-equip the end separately ...
|
|
Schneider Intermediate Relay Model Letter Meaning
RXM: Schneider's miniature center relay
The first 2: indicates the number of contacts, and the normally open contact is 2
LB: Indicates that the product has LED light
The second 2: indicates the number of contacts, and the normally closed contacts are 2
BD: Indicates that the supply voltage used is DC 24V
...
|
|
Precautions for motor operation over 60Hz - Schneider
What problems should be paid attention to when the motor works beyond 60Hz?
The following precautions should be taken when operating beyond 60Hz
(1) Machinery and equipment should have sufficient potential to work at this speed (mechanical strength, noise, vibration, etc.).
(2) ...
|
|
Schneider EZD series molded case circuit breaker is recommended
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.
|
|
Introduction to Schneider limit switch series
1. XCKN compact limit switch
Light and medium load use;
Waist-shaped device holes for easy adjustment of mechanical errors;
Bipolar isolation definitely disconnects the contacts;
External waterproof sealing joint, the protection level is higher than that of rubber sleeve sealing pipe;
Engineering plastic body, avoid temperature ...
|
|
The difference between vector and general use of inverter - Schneider
1. The control accuracy of the vector type is higher than that of the general-purpose type.
2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...
|
|
Features of Schneider elliptical gear flowmeter
Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.
|
|
Schneider PLC failure steps
(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above.
(2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...
|
|
Knowledge of Schneider Lexium32 servo motors
Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...
|
|
The difference between Schneider verification and calibration
(1) The intent is different
The intent of the verification is to carry out a mandatory comprehensive appraisal of the measuring equipment. This comprehensive identification of areas attributed to the value of the same value is a top-down process of value transfer. The verification shall identify whether the measuring equipment meets the specified requirements.
This kind of regulation requires ...
|
|
The selection method of inverter power - Schneider
The system power is equal to the product of the inverter power and the motor power, as long as both are operating at a higher power, the system power is higher. From the power point of view, when selecting the power of the inverter, the following points should be noted:
...
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Schneider touch screen touch deviation causes
(1) Problem 1: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye when checking the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: ...
|
|
U-tube manometer error analysis – Schneider
(1) Temperature error. This refers to the change of the length of the scale and the density of the working fluid due to the change of ambient temperature, and the former can be ignored in general, and the latter should be appropriately corrected. For example, when water is changed from 10°C to 20°C, its density changes from 999. 8kg/m^3 reduced to 999.8kg/m^3 ...
|
|