In the food and beverage industry, level measurement of a wide range of tanks is critical, but there are many challenges.
For example, steam, condensate, temperature changes, or various gases (nitrogen and other maintenance gases) above the level surface in some tanks can affect the accuracy of the measurement, and it is difficult to ensure the accuracy of the traditional hydrostatic measurement plan in the production process of liquid level measurement with strict requirements for liquid level measurement. In addition, there are viscous or viscous media that can stick to the sensors installed in the tank, resulting in false signals, etc.
In response to these problems, we are proud to introduce the new touchless radar level sensor LW2720, which sets new standards in terms of speed and accuracy.
When the LW2720 is installed in a tank up to 10 meters high, accurate level measurement can be carried out even in the presence of an integrated mixer or spray ball. Different media will not affect the measurement.
Product Advantages:
● Outstanding features
80 GHz technology completes the collection of accurate level measurements
• Health programmes
Hygienic area certified with IP66/68 and IP69K protection
● Easy to set up
Standard M12 connection is selected, plug and play; Only one number is required to set the parameters; A wide range of adapters are available
● Reliable quality
We offer a 5-year warranty on our products
What problems can the LW2720 handle?
● Mixing tank with agitator
Thanks to the non-touch measuring principle, it will not fail due to collision with the agitator or mixer
● CIP process storage tanks
Specially designed for hygienic use, suitable for CIP/SIP processes as well as for the use of spray balls
● Storage tanks
The LW2720 can monitor the level of tanks up to 10 meters. Not! Blind! District!
● Process tanks
The batch filling process can be optimized, as the sensor is not affected by changes in medium temperature or density
Radar level sensor LW2720
● 80 GHz for millimeter-accurate measurement of liquid levels up to 10 meters
● Non-touch measuring principle: no problems due to deposits or abrasion
● Certified for use in sanitary areas
● The device is simple and maintenance-free
● With IO-Link, the measured value can be digitally transmitted, plug and play, and can be connected to the IT system for remote sensor parameter setting and liquid level monitoring
|
More on that
|
Accuracy adjustment of inclination sensors – ifm
The first step is the ambient temperature, what is the normal temperature? 25±15°C, if there is a regular measurement temperature of the measured specimen, then the regular temperature shall prevail;
The second step, the condition of the product, that is, the normal operating condition, ...
|
|
ifm takes you through level sensors
How it works
Static pressure measurement principle: when the liquid level sensor is put into a certain depth in the liquid to be measured, the pressure on the liquid surface of the sensor is formulated as: Ρ = ρ .g.H + Po formula: P: The pressure on the liquid surface of the transmitter ...
|
|
Introducing the ifm all-metal inductive sensors
Changes in mechanical spacing can be detected directly and parameterized easily via the IO-Link interface
Interval measurement provides robust endpoint position detection
High quality stainless steel housing (316L)
The temperature scale is the most ...
|
|
Sensors, temperature sensors, RTDs and thermocouples – ifm
RTDs and thermocouples are the most commonly used temperature sensing elements for temperature sensors. The operating principle of thermocouple temperature sensor is that the two ends of the contact surface of two kinds of incompatible metals produce a weak and weak voltage when the temperature is inconsistent, and the temperature is measured by expanding the electric, which is not necessary to measure the high temperature. RTD Temperature Sensors ...
|
|
DV Series Signal Light Wins "Red Dot Design Award"
On July 9, 2018, the grand Red Dot Awards ceremony was held at the Aalto Theater in Essen, Germany, and the prestigious "Red Dot Planning Award" 2018 was presented.
This year's contestants from 59 countries paid tribute to the Red...
|
|
Precautions for using pressure sensors
The pressure sensor is an instrument that can accept pressure signals, and it is widely used in railway transportation, intelligent buildings and other occupations.
First, prevent solder slag from ...
|
|
Basic parameters of load cells – ifm
A load cell (also known as a load cell) is a type of sensor that converts a physical force signal into an electronic signal. From the basic principle, it is divided into strain type, piezoresistive type, piezoresistive type, foot type, etc.
Non-repeatability: In the same ring ...
|
|
The main feature of the wireless sensor network is the ifm sensor
(1) Large-scale
In order to obtain accurate information, many sensor nodes are usually arranged in the monitoring area, perhaps in the tens of thousands, or even more. The large-scale nature of the sensor network contains two implications: on the one hand, the sensor nodes are distributed in a large geographic area, such as in the original ...
|
|
High-frequency pressure sensor output signal – ifm
The conversion of the pressure to the electrical signal is done by the physical deformation of the strain gauge, and the strain gauge is bonded to the diaphragm of the pressure sensor and wired into a Wheatstone bridge structure. The pressure exerted on a high-frequency pressure sensor causes the diaphragm to flex, which causes the strain gauge to strain. Strain will occur ...
|
|
Choice of pressure sensor – ifm
The first step in selecting a pressure sensor is to determine the pressure to be measured. Exciter sensors are divided into mechanical pressure and pneumatic pressure (hydraulic). The mechanical pressure unit is generally N.KN.KGF, etc. The pneumatic and hydraulic units are generally KPA, MPa, PSI, etc. This article describes the selection of mechanical pressures.
...
|
|
Applications of IFM capacitive sensors
1. ZCS1100 fine capacitance displacement sensor. This sensor can detect piezoelectric micro-displacement, shaking table, electron microscope fine-tuning, astronomical telescope lens fine-tuning, fine micro-displacement measurement, etc. The sensor is a single channel, high-performance linear displacement measurement system, innovative ...
|
|
Failure analysis and definition of ifm vortex flowmeters
Vortex flowmeter series instrument because of the use of the environment is special or harsh in the field work sometimes present such and such problems, resulting in production will be affected, vortex flowmeter and orifice flowmeter and V-cone flowmeter are different, as far as the orifice flowmeter is concerned, it is the standard orifice plate and multi-parameter ...
|
|
Differential pressure sensor function – ifm sensors
A differential pressure sensor is a sensor used to measure the difference between two pressures, usually used to measure the pressure difference between the front and rear ends of a device or component.
A typical application of differential pressure sensors is to measure the difference in exhaust pressure between the front and rear channels of the exhaust particulate trap of a passenger car engine.
|
|
Advantages of IFM controllers:
1. The programming method of the programmable ifm controller is simple and easy to learn
Programmable ifm controller ladder diagram is the programming language of the more used PLC, its circuit symbols and expressions are similar to the schematic diagram of relay circuits, the ladder diagram language is intuitive, easy to learn and understand, understand the relay ...
|
|
Pressure sensor encounters fault handling method – ifm
Don't panic when you encounter a problem with the pressure sensor, you should find a way to solve it, if the pressure rises, the transmitter output will not rise.
In this case, first look at the pressure sensor pressure interface to see if it is leaking or blocked; If not, check the connection form and power supply; If...
|
|
Moisture-proof method for sensors – ifm
As an accurate detection device, if the sensor is damp, it will be troublesome, the sensor will affect its accuracy and stability when it is damp, and it will form a problem if the sensor is used in a more important place, then the loss of the formation is very heavy. In '08 there was a ...
|
|
The criterion for judging vibration sensors – ifm
1. The size of the measured oscillation;
2. The frequency scale of the oscillating signal;
3. The environment of the oscillation test site;
1) Selection and measurement scale of the sensitivity of the oscillation sensor
Estimating the amount of oscillation will help ...
|
|
The ifm identification system has an RFID antenna with IO-Link
Sensitive parameterization, diagnostics and data processing of ifm sensors are suitable for many different uses9 versions, suitable for a variety of different types of sensitive parameterization, diagnostics and data processing with I/O-Link Ideal for the identification of small data volumes with LR DEVICE or IO-L ...
|
|
Essentials for the selection of ifm controllers
1. The ifm controller has a control function
Another important reference feature for the purchase of ifm controllers is the ability to control movements and other applications. Fulfillment of these functional requirements requires I/O, as well as a strong processor and the ability to prioritize missions.
Programmable Drum Switches (PDS...
|
|
Three major load cells – ifm sensors
1. Resistance strain gauge
The resistance strain gauge is a resistance wire mechanically distributed on a substrate made of organic materials, that is, it becomes a strain gauge. An important parameter for him is the sensitivity coefficient K. When his ends are subjected to the F force, they will elongate, that is, they will be deformed. ...
|
|