The first step is the ambient temperature, what is the normal temperature? 25±15°C, if there is a regular measurement temperature of the measured specimen, then the regular temperature shall prevail;
The second step is the condition of the product, which is the normal operation status, and the abnormal operation should be stopped in time to deal with the problem;
The third step, the experimental method, mainly according to the rules in the relevant documents of the test sample, is installed on the high-precision turntable with the theoretical output of zero degree azimuth, and then the turntable is adjusted to make the output value of the inclination sensor zero, and then the viewpoint value displayed on the turntable is cleared to zero, and then within the measurement range of the sensor, at least five measurement points are selected, and the readings of the inclination sensor at the test point are recorded respectively. In all test points, from the small point of view (or negative point of view) to the large point of view (or front point of view) in turn, it is a positive stroke, vice versa reverse stroke, each sensor measures a positive stroke or reverse stroke, and among all test points, the absolute value of the error is the largest as the accuracy.
It needs to be noted that when the product output is irregularly beating, it is electrically closed and changed to a manual test to reduce the disturbance of the outside world, and the device should be carried out in the way of the relevant document rules of the sample, and the device surface and the horizontal plane are horizontal/vertical/other viewpoints for the sensing zero point. The test time is greater than or equal to 12 hours after the completion of zero point temperature drift, the accuracy is greater than or equal to 0.02 °, 12 hours after the completion of zero point temperature drift, you can test the accuracy by yourself, the accuracy is less than 0.02 °, and the zero point temperature drift is completed 12 hours after the development engineer admits the accuracy of the test.
|
More on that
|
Current sensor features – ifm
1. High sensitivity. The strength of the detected signal is getting weaker and weaker, which requires a significant increase in the sensitivity of magnetic sensors. The use includes current sensors, angle sensors, gear sensors, and space environment measurement.
2、 ...
|
|
Zero drift of pressure sensors – ifm
Zero drift is an important indicator that affects the function of the pressure sensor, so when the problem occurs, we should pay attention to it, so what is zero drift? Zero drift refers to when the input signal of the expansion circuit is zero, due to the influence of temperature changes, power supply voltage instability and other factors, so that ...
|
|
How ifm sensors determine the exact installation location
When installing an ifm sensor, the first thing to do is to confirm the orientation of the sensor and then to install it correctly. So how do we confirm the orientation of the sensor?
The ifm sensor confirms the detailed orientation of the device ...
|
|
Load cell weighing reasons and connection to PLC – ifm
The principle of a load cell is that the gravity on the measured object is converted into a measurable output signal in a certain proportion.
The load cell can generally be connected to the PLC or the quadratic meter for the number display.
Regarding the use of PLC connection load cells in the factory, we generally have two ways to ...
|
|
ifm ifm sensors detect objects contactlessly
Capacitive ifm sensors have many applications in everyday life. It is capable of viewing non-metallic materials as well as detecting objects in a non-contact manner.
Capacitive ifm sensors are resistant to interference. When an object is detected, the small ...
|
|
Precautions for the installation of ultrasonic level gauges
1. The appearance is installed outdoors, and it is recommended to install a sunshade to prolong the service life of the appearance.
2. Wire and cable protection pipes should be sealed to avoid water accumulation.
3. Although the appearance itself is equipped with lightning protection equipment, when the appearance is used in the multi-lightning area, it is advocated to distinguish the inlet and outlet lines on the surface.
|
|
The difference between a fiber optic sensor and a photoelectric sensor – ifm
The first point is that photoelectric sensors and fiber optic sensors work differently
First of all, from the principle of operation of the two, first of all, the photoelectric sensor is operated according to the principle of the photoelectric effect, that is to say, when the light hits the photoelectric sensor made of semiconductors, the light will be announced.
|
|
Precautions for the installation of high-frequency pressure sensors – ifm
The depth of the internal thread of the installation with the sensor should be greater than the length of the external thread of the sensor itself, so as to avoid the sensitive diaphragm of the sensor pushing to the bottom of the internal thread, so that the sensor is affected by stress.
If the size of the internal thread has been ...
|
|
Common faults in eddy-current sensors – ifm
The eddy-current displacement sensor is a commonly used measuring instrument, which can accurately measure the static and dynamic relative displacement changes between the measured body (if necessary, a metal conductor) and the end face of the probe, and has the advantages of flexible use, stable function, high reliability and simple protection.
...
|
|
Daily maintenance of ifm sensors
The maintenance of the sensor is an important step to ensure its normal operation and extend its service life. Here are some claims for caring for your sensors:
1. Regular cleaning: Sensors may be affected due to the accumulation of dust, grime, or chemicals. It is necessary to clean the sensor regularly, ...
|
|
Attention to the selection of industrial sensors – ifm
1. According to the measurement object and measurement environment
In order to carry out a detailed measurement operation, it is necessary to consider the principle of the sensor first, which needs to analyze many factors before confirmation. Because, even if the same physical quantity is measured, there are sensors with multiple principles to choose from.
|
|
A complete list of daily maintenance methods for ifm sensors
IFM sensors are widely used in electromechanical control systems due to their high sensitivity, low output impedance, simple structure, strong anti-interference ability, high output power and high measurement accuracy. So how should we maintain it during use? Here's what we'll do for you...
|
|
How to care for ifm sensors
1. When measuring the liquid pressure, in order to prevent the sensor from being damaged by overpressure, the device position of the sensor should prevent the impact of the liquid.
2. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer pipe.
3. The impulse pipe should be installed in a place where the temperature fluctuation is small.
...
|
|
Fuel level sensors monitor the cause of the fuel level – ifm
The oil level sensor according to the resistance is mechanically connected to the float, and the float can rise or fall with the fuel level, and the resistance of the sensor changes as the float moves. The sensor used is part of the current balance circuit in the fuel gauge display circuit, which is generally used to drive ...
|
|
ifm UGT505 is used to improve air quality
Green City Solutions is committed to improving urban air quality. As a result, they developed CityTree, the world's first bio-skill air filter. The filter is integrated in the UGT505.
CityTree uses ...
|
|
Ifm flow sensors ensure safety
Ifm flow sensors ensure safety
Specially developed for monitoring the fresh air and exhaust of machines
Optimized performance is achieved through special air conditioning
Rugged probes for demanding applications
2-in-1: Flow rate and temperature ...
|
|
Features and benefits of fiber optic sensors
Fiber optic sensors have the advantages of extremely high sensitivity and accuracy, good inherent safety, anti-electromagnetic interference, high dielectric strength, corrosion resistance, integration of sensing and transmission, and compatibility with digital communication systems.
High sensitivity
...
|
|
Signal discrimination method generated by vibration sensors – ifm
1. Distinguish according to the gap voltage
The oscillation sensor outputs a voltage signal that contains both DC and AC. The amount of DC corresponds to the uniform distance between the sensor and the probe, also known as the void voltage. The traffic corresponds to the oscillating signal. If the void voltage is normal, the alternating current is usually normal.
...
|
|
A brief description of the features of ifm multi-code readers
Powerful detection function
The new multicomputer delivers 4x higher resolution for reliable reading results, 10x faster calculation times, and 10x faster setup.
Teach button
Its sensing ...
|
|
Use of the ifm OGD580 laser distance sensor
The OGD580 is a spaced sensor (PNP type) with two digital output channels, each of which can be set to normally open, normally closed, or closed, depending on the requirements.
OGD580 consists of three parts: laser emitter, ...
|
|