In electrical switchgear, the external connection of high-current frame circuit breakers (ACBs) is usually achieved by connecting multiple cables per phase in parallel. When using the conventional flat busbar solution, multiple bolt fastening holes need to be cut in the standard busbar to complete the cable connection, and each busbar needs to be designed separately. In addition, due to the large size of the copper bar under high current conditions, the operating space when connecting with external cables is very limited.
From the TS to the VX Ri4Power Maxi PLS series, Rittal brings better products to the market with innovative thinking, offering a range of high-quality solutions to the challenges of cable connection.
Rittal's new Maxi-PLS busbar system is launched!
Classic products, new start
● Rittal's new Maxi-PLS busbar system continues Rittal's traditional high standardization, easy installation and scalability, but also has been given a more intimate design.
New Product Features:
Maxi-PLS bus system
● Three different sizes of special-shaped copper bar type, the rated current can meet the requirements of 1900A/2500A/5400A.
● The product is compatible with VX standard cabinets, and can also be adapted to TS8 cabinets with the support of standard adaptation rails
● It has the solution of laminated busbar, cable annular nose, round conductor cable head connection, and can also be connected to hard copper bar through connection accessories.
● The special-shaped copper bar can ensure that multiple planes are connected to the outside, and there is no need to open holes when connecting, so as to fully ensure the overall strength of the copper bar.
Advantages of Maxi PLS solution:
Part.1. Standard adaptation
The length of the special-shaped bus can be adapted to the width of the standard cabinet, and it can be directly installed in the standard cabinet without processing.
Part.2. Beautiful and convenient
The Rittal's standard stepped inlet busbar structure is "outstanding" and can fully guarantee the convenience of connection, which can easily ensure that the busbar is in a uniform installation position in different cabinets, and improves the work efficiency of customers.
Part.3. Rich connection forms
The busbar has a variety of connection methods, and can be connected to various types of cables or copper bars without punching holes. The connection process does not damage the copper itself, and it can be flexibly adjusted according to the needs after installation.
Part.4. Various installation methods
In addition to the stepped cable installation method, the horizontal installation at the top of the cabinet and the vertical installation scheme at the rear are retained to meet different installation and connection needs, and can efficiently use the space in the cabinet.
The Maxi-PLS series completes some of the missing parts of the traditional cabinet electrical connection, and the comprehensive solution is a benchmark for various problems when connecting cables. In the future, this new product will also take root in all walks of life, opening a "new version" of safe and reliable efficient power distribution for customers!
|
More on that
|
When winter arrives, Rittal heaters bring warmth to the cabinets
We know that electronic and electrical equipment is installed in the electrical cabinet, in fact, there are working temperature requirements, the general storage temperature can not be lower than minus 25 degrees, the working temperature can not be lower than minus 20 degrees, but now the outdoor temperature in the north is very simple to reach the lower limit of this working temperature, this time heating ...
|
|
Rittal cabinets – the composition and function of low-voltage distribution cabinets
The power distribution panel is mainly composed of incoming cabinets, outgoing cabinets, capacitor cabinets, metering cabinets, etc.
Incoming cabinet: also known as the receiving cabinet, is a device used to receive electrical energy from the power grid (from the incoming line to the busbar), generally installed with circuit breakers, CT, PT, isolation knives and other components.
Outlet cabinet: ...
|
|
Rittal cables – safety requirements for cables
1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m.
2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is Peak Load? What is trough load? What is Average Load?
A: Peak load refers to the maximum load that can occur on the grid and the user in a day. The trough load is the hourly average of the least amount of usage that occurs in the grid and the users in a single day.
|
|
Common faults and solutions for Rittal cabinet air conditioners
If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start;
Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high.
The voltage of the air conditioner is unstable, and the compressor cannot be started normally.
|
|
Rittal cabinet - judgment and treatment of energy storage faults in high-voltage switchgear
In the high-voltage cabinet with the spring energy storage operating mechanism, the energy storage must be stored in advance before closing. The energy storage mechanism is driven by an electric motor and the gear mechanism lengthens the spring. There are two types of operation methods: electric and manual. Manual failure to store energy should be due to a mechanical failure of the mechanism. Manual energy storage ...
|
|
Rittal cabinets – installation steps and rules for cabinet placement
Cabinet installation steps:
1. Before installing the cabinet, check whether the exhaust device of the cabinet is stable, whether the number of equipment support plates is complete, and whether the pulleys and support columns are stable.
2. The model, specification and device orientation of the cabinet should meet the planning requirements.
3. Cabinet ...
|
|
Rittal cables – the main use of power cables
Power system: The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (basically replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables, magnet wires and power equipment...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
How to set the temperature of the Rittal air conditioner
1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters.
2. High temperature alarm: ...
|
|
Introduction to the process characteristics of the Rittal cabinet - PS frame universal control cabinet
1. The cabinet door is 25mm from the ground and 2.5mm thick mounting plate, and there are 20mm wide U-shaped curved edges on both sides, which makes the mounting plate stronger and easy to handle.
2. The three cable introduction cover plates at the bottom of the box can be replaced with each other, which is easy to move, easy to import cables, and easy to open holes into the line.
3 ...
|
|
What are the functions on the operation panel of the inverter control cabinet?
Display parameters: The control panel can display various parameters of the inverter, such as input/output voltage, current, frequency, speed, etc.
Parameter setting: The control panel can set various parameters of the inverter, such as operating mode, frequency range, acceleration time, deceleration time, etc.
...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
Why use transformers to measure high voltage and high currents?
Answer:
(1) Expand the scope of use of the instrument. As long as the transformer with different transformer ratios and converter ratios is used in conjunction with a voltmeter with a full voltage of 100V and an ammeter with a full current of 5A, it will be ...
|
|
The customized outdoor cabinet of the Rittal integrated pumping station was successfully delivered to build an ecological water environment
The handover ceremony of the customized outdoor cabinet of the integrated pumping station jointly developed by Rittal and Shu Pengshi was held in Rittal (China) Company. Mr. Tian Ming, General Manager of Shupenshi Environmental Technology (Changzhou) Co., Ltd., and Mr. Xue Boliang, Technical Director, attended the handover ceremony with technical engineers. Power...
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
Rittal cables – the meaning of the first letter of the number of the control cable
First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This cable can transmit data signals and has a certain resistance to wear and chemical corrosion, so ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main differences between electronic control equipment and power distribution equipment products?
Answer: The function of electronic control equipment is mainly control, and the function of power distribution equipment is mainly transmission.
How much is the external design of domestic electronic control equipment products?
Answer: Control panel, control cabinet, control box and console ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is Phase Order?
Answer: It is the order of the phases, which is the sequence in which the instantaneous value of alternating current changes from negative to positive through zero
What is the safety distance of the human body grounding point when a grounding fault occurs in high-voltage equipment?
A: Indoor should be larger than 4 m, outdoor should be larger than 8 ...
|
|
Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets
▲ GGD AC low-voltage distribution cabinet:
(1) Use
GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...
|
|
Rittal cabinets – daily maintenance methods for high and low voltage distribution cabinets
Complete set of electrical maintenance knowledge:
1. Low-voltage distribution cabinet
1. Regularly check whether there are traces of pest activity in each cabinet, and carry out trapping regularly.
2. Check whether the warning signs and maintenance signs are placed correctly.
3. Check whether the emergency tools and lamps are in order.
|
|