The load cell is a relatively easy to damage component in the weighing cell, and it is easy to cause damage to the sensor due to impact, overload, aging, high temperature, corrosion, etc.

(1) Physical observation: observe whether the appearance of the load cell is deformed, cracked, etc.

(2) Measuring resistance: After measuring the input and output resistance of the load cell with a multimeter, if there is a big difference with the manual, the sensor will be damaged. If there is no manual, the resistance value is determined.

1: Input resistance≥ output resistance> bridge resistance

2: The bridge resistance is equal or equal in pairs

(The input resistance is between EXC+ and EXC-, the output resistance is between SIG+ and SIG-, and the bridge resistance is EXC+ to SIG+, EXC+ to SIG-, EXC- to SIG+, EXC- to SIG-)

From this, it is possible to determine whether the load cell is damaged or not.

(3) Measure the voltage

First of all, the voltage value between the meter terminal EXC+ and EXC- is measured in the DC voltage range of the multimeter, which is the excitation voltage of the load cell, and under normal circumstances, the excitation voltage (between EXC+ and EXC-) is 5-10V. Now, taking DC5V as an example, the output sensitivity of the load cell is generally 2mv/V, that is, the linear relationship between the excitation voltage of the load cell output signal per 1V is 2mv.

When the device is unloaded, the output voltage (between SIG+ and SIG-) is close to 0, which is less than the maximum output of the sensor. (Maximum output of the sensor = excitation voltage * sensor sensitivity, the sensitivity of the load cell sensor is mostly 2mV/V), beyond this range, the sensor needs to be replaced. )
Sick Sensors - How to test the quality of load cells?

More on that
Sick Sensors - Top 10 Commonly Used Sensors in the Internet of Things Sick Sensors - Top 10 Commonly Used Sensors in the Internet of Things

01 Temperature sensor Temperature sensors measure the heat energy in a heat source, allowing it to detect temperature changes and convert those changes into data. Machinery used in manufacturing often requires a specific level of ambient and equipment temperature. Similarly, within agriculture, soil temperature is ...

Introduction to the advantages and disadvantages of Sick sensors Introduction to the advantages and disadvantages of Sick sensors

1. Advantages (1) Germany SICK flow sensor can be used to measure industrial conductive liquids or slurries. (2) No pressure loss. (3) The measuring range is large, and the diameter of the electromagnetic flow transmitter is from 2.5mm to 2.6m. (4) Germany Sick SICK traffic transmission ...

Sick Sensors – What are the Common Types of Proximity Sensors? Sick Sensors – What are the Common Types of Proximity Sensors?

Capacitance – As the name suggests, these sensors work by recording changes in capacitance, which is a function of charge and voltage between two surfaces with an air gap or other material known as the dielectric constant. When the object to be measured enters the sensor field, it has an impact on the medium.

How to adjust the sensor of Sick NT6-03022? What are the methods? How to adjust the sensor of Sick NT6-03022? What are the methods?

1. Self-regulation. At the beginning of use, please check whether the switch itself is in good condition, whether the appearance is in good condition, etc. 2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...

Common fault causes and treatment methods of Sick sensors Common fault causes and treatment methods of Sick sensors

1. No weighing reading This kind of fault is generally more common, the weighing value of a certain scale is zero, regardless of whether there is something on the scale, its weighing value is always zero. There are several reasons for the above failure: a. the sensor is damaged, b. the line is open, c. the signal is ...

Sick 3D cameras enable high-speed inspection of automotive bearings Sick 3D cameras enable high-speed inspection of automotive bearings

Automobile is one of the pillar industries of the national economy, with the rapid development of China's automobile industry, the pursuit of higher detection speed is gradually reflected. The automobile steering shaft is an important part of the automobile power system, the upper part is fixedly connected with the steering wheel, and the lower part is connected with the steering gear; Its performance of ...

Sick Sensors - Infrared sensors are classified according to the way they are emitted Sick Sensors - Infrared sensors are classified according to the way they are emitted

Depending on the way of transmission, infrared sensors can be divided into two types: active and passive. 1. Active infrared sensor The transmitter of the active infrared sensor emits a modulated infrared beam, which is received by the infrared receiver, thus forming a warning beam composed of an infrared beam ...

SICK Safe EFI-pro: The new generation of SICK safe communication protocol SICK Safe EFI-pro: The new generation of SICK safe communication protocol

In this issue, we will delve into the technical details of the Safe EFI-pro System, and then we will share with you about the typical application scenarios of the Safe EFI-pro System. 1. What is Safe EFI-pro System? Safe EFI-pro: The new generation of SICK ...

Sick Sensors – The lead method for RTD sensors Sick Sensors – The lead method for RTD sensors

1. Two-wire system: the way to connect a wire at both ends of the thermal resistance to draw out the resistance signal is called the two-wire system: this lead method is very simple, but because there must be a lead resistance r for connecting the wire, the size of R is related to the material and length of the wire, so this lead method is only applicable to ...

The main characteristic parameters of the sensors from SICK from Sick The main characteristic parameters of the sensors from SICK from Sick

Key Characteristics of SICK Sensors (Displacement Sensor Principle) Nominal resistance: The resistance indicated on the potentiometer. Promise error: The percentage of the ratio of the difference between the nominal resistance and the actual resistance to the nominal resistance is called the resistance error, which indicates the accuracy of the potentiometer. Promise...

Introduction to the functions and characteristics of Sick sensors Introduction to the functions and characteristics of Sick sensors

1. At present, SICK pressure sensors can be used in combination with computers and instruments to improve operation and reduce errors. The human-machine dialogue function is the main feature of SICK pressure sensors, and the display device and input keyboard equipped with it become the medium for human-machine dialogue. 2. SICK pressure sensing ...

Sick sensor – the difference between photoelectric sensor and infrared sensor Sick sensor – the difference between photoelectric sensor and infrared sensor

Photoelectric sensors A photoelectric sensor is a device that converts an optical signal into an electrical signal. Its working principle is based on the photoelectric effect. The photoelectric effect refers to the phenomenon that when light hits some substance, the electrons of the substance absorb the energy of the photons, and the corresponding electrical effect occurs. According to the photoelectric effect ...

Sick sensor - introduction to the characteristics of photoelectric sensors Sick sensor - introduction to the characteristics of photoelectric sensors

1. Long detection distance If the detection distance of 10 m or more is retained in the through-beam type, it is possible to achieve detection that is not possible with other detection methods (magnetic, ultrasonic, etc.). 2. There are few restrictions on the detected objects Due to the detection of shading and reflection caused by the detection of objects ...

Sick OD2000 laser displacement sensor was launched Sick OD2000 laser displacement sensor was launched

The OD2000 is an excellent multi-range sensor with a laser displacement sensor measuring within 1,200 mm with high accuracy. Technology based on the principle of laser triangulation, as well as the versatility of the measuring range, make it suitable for many different industry applications.   OD2000 multi-range not only solves the problem of electric ...

Sick Sensors – How to use color sensors Sick Sensors – How to use color sensors

Method 1: Put the color sensor on the white object, turn on the red filter, at this time the sensor will emit the frequency, count the emitted frequency, when the count reaches 255, there is a time, this time is recorded as T1. Turn on the green filter, at this point the sensor will ...

Sick sensor - the detection procedure of the sensor, the precautions in the detection process Sick sensor - the detection procedure of the sensor, the precautions in the detection process

The detection procedure of the sensor 1. Symptom Judgment: Infer the location where the malfunction may occur. 2. Decoder detection: Confirm whether the suspected sensor has a fault code in the decoder, and strengthen the judgment in the data stream. 3. Inspection around the sensor: In case of ...

Introduction to the characteristics of the Sick sensor - infrared distance sensor Introduction to the characteristics of the Sick sensor - infrared distance sensor

1) Long-distance measurement, in the case of no reflector and low reflectivity, it can measure a long distance; 2) There is a synchronous input terminal, which can be measured synchronously by multiple sensors; 3) Wide measurement range and short response time; 4) Compact design, easy to install, easy to operate ...

Sick launched a new diffuse reflection long array photoelectric sensing Sick launched a new diffuse reflection long array photoelectric sensing

The logistics industry has always been a strong area of SICK, in response to the detection of various goods on different conveyor lines and the diverse needs of customers, SICK has launched a series of photoelectric sensors such as G6, Z18, W16, W26 and Ray26 - which can detect cartons, baskets, uneven appearance, transparent bottles, laminated bags, etc.

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.

Sick releases the Visionary-T Mini AP 3D vision camera Sick releases the Visionary-T Mini AP 3D vision camera

The Visionary-T Mini is a 3D snapshot camera based on TOF (Time-of-Flight) that outputs internally calibrated 2D grayscale images and 3D point cloud data at the same time, helping users reliably identify and locate objects in indoor and semi-outdoor environments. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top