A brief description of Mitsubishi MELIPC industrial control products

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

MELIPC's intelligent industrial control product system includes MI50000 analysis category, MI2000 monitoring strain, and MI1000 gateway category, forming a comprehensive data collection, processing, and transmission solution between the FA production site and the IT system, and using edge accounting to complete the self-discipline and sloppy IoT layout, and processing the production site data at one time, reducing the amount of communication, and improving real-time and security.

                                  A brief description of Mitsubishi MELIPC industrial control products

MI5000 is Mitsubishi Electric's flagship product for real-time analysis and diagnosis, equipped with a high-performance processor Intel? Core? i7, Windows, and VxWorks™ OS can be run at the same time, effectively reducing the cost of system construction and saving equipment space. The MI5000 can communicate the control information and production information of CC-Link IE Field network connected devices with a minimum of 1 ms, completing high-precision equipment control and high-speed collection of production information. MELIPC is set up by software to collect data from Mitsubishi Electric and other brands, and its high compatibility with the IT system can improve the collaboration power between the production site and the cloud and open source servers.

MI2000 is a mid-range product suitable for monitoring the production site, which can use PCI and PCI Express expansion ports to expand the system, use CC-Link IE field network boards to complete high-speed collection of production information, and use input and output boards to complete equipment control. In addition, a variety of general-purpose PCI boards can be used to expand the system.

The MI1000 is a compact, low-cost device suitable for IT system gateways, and is suitable for high-degree freedom settings in various situations. The MI2000 and MI1000 do not use fans, so they do not need to be replaced, cleaned or other maintenance.
More on that
Mitsubishi touch screen common faults and solutions Mitsubishi touch screen common faults and solutions

Fault 1: Mitsubishi touch screen contact deviation Phenomenon: The direction of finger contact does not match the mouse arrow. Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing. ...

Mitsubishi Electric Solutions serves the entire process of lithium battery production Mitsubishi Electric Solutions serves the entire process of lithium battery production

Mitsubishi Electric's MES system MELNAVI has a standard database, which can meet the needs of the 11 major functions required by MES, and also supports flexible secondary development, which can easily connect the upper ERP and lower automation products in a short time, and can also be connected to other APS scheduling software and analysis systems. ...

Mitsubishi PLC network structure Mitsubishi PLC network structure

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Combine...

Mitsubishi inverter fault judgment method Mitsubishi inverter fault judgment method

1. UVT problem UVT is an under-voltage problem, and I believe that many customers will still encounter such problems in use. The common undervoltage detection point of Mitsubishi inverter is the voltage on the DC bus side, and a low voltage value is sampled after the voltage division of the large resistance resistor, which is compared with the standard voltage value ...

The working principle of the servo motor of the Mitsubishi CNC system The working principle of the servo motor of the Mitsubishi CNC system

1. The servo mainly relies on the pulse to position, basically it can be understood in this way, the Mitsubishi CNC system maintenance servo motor receives a pulse, and it will rotate the angle corresponding to the pulse, so as to achieve displacement, because the servo motor itself has the function of sending out pulses, so the servo motor ...

Mitsubishi PLC's communication inspection method Mitsubishi PLC's communication inspection method

When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port. ...

Mitsubishi inverter installation reactor advantages Mitsubishi inverter installation reactor advantages

1. Characteristics of the output reactor: 1. It is suitable for reactive power compensation and harmonic control 2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively protect the Mitsubishi inverter and improve the power factor, which can block the ...

Introduction to the Mitsubishi PLC encryption process method Introduction to the Mitsubishi PLC encryption process method

The encryption process is as follows: ** Open the serial port for the first time [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here) [00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 1, Parity: Ev ...

Three common communication methods of PLC - Mitsubishi Three common communication methods of PLC - Mitsubishi

A PLC network consists of multiple subnets. The communication process of each subnet is determined by the communication protocol. The communication method is the core content of the communication protocol. The means of communication include visit control and data transmission. What are the three common communication methods of PLC? ...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Introduction to the names and effects of capacitors in different circuits Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...

An introduction to the types of data inside the Mitsubishi FX series An introduction to the types of data inside the Mitsubishi FX series

A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following forms in terms of structure or number system. (1) Decimal number Decimal numbers are also known as word data in PLC. It is first and foremost ...

How to configure the mechanical torque period of the inverter - Mitsubishi inverter How to configure the mechanical torque period of the inverter - Mitsubishi inverter

1. The starting torque that makes the mechanical equipment roll from a standstill state is usually positive, and generally larger than the torque required to maintain constant velocity movement, such as most feeders, material conveyors, mixers, mixers, etc., it may reach the additional torque of the Yuan Yuan Yuan Yu Yao Yuan Yuan ...

Characteristics of servos and advantages of Mitsubishi servos Characteristics of servos and advantages of Mitsubishi servos

The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.

Mitsubishi PLC FX series position control unit Mitsubishi PLC FX series position control unit

The FX-20GM is a 2-axis positioning machine that can be operated independently. 1. Pulse output unit 1. Point-controlled pulse output unit F2-30GM 2. Pulse output module FX-1PG (for FX2 and FX2C) ...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles. ...

Review and comparison of Mitsubishi PLC control inverter methods Review and comparison of Mitsubishi PLC control inverter methods

1. The switching signal of PLC controls the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...

Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use

Tokyo, June 9, 2021 – Mitsubishi announced the upcoming launch of its industrial T-series 2.0kV insulated gate bipolar transistor (IGBT) module, the world's first IGBT1 with a 2.0kV withstand voltage, June 30. This module is ideally suited to increase the power of renewable energy power converters ...

Mitsubishi servo motor realizes positioning function Mitsubishi servo motor realizes positioning function

The motion control command of the PLC realizes the perfect positioning function. Briefly describe the Mitsubishi PLC positioning instructions, which can be divided into origin regression instructions DSZR, ZRN, positioning instructions PLSY, PLSR, DRVI, DRVA, variable speed operation PLSV.3 In the meantime, PLSY and PLSR are pulse output instructions, and their positioning functions are relatively ...

The difference between Mitsubishi PLC and Siemens PLC The difference between Mitsubishi PLC and Siemens PLC

The programming philosophy is different Mitsubishi PLC is a Japanese brand, programming is intuitive and easy to understand, and it will be easier to learn, while Siemens PLC is a Germany brand, the instructions are more general, it is more difficult to learn, but there are fewer instructions, and Mitsubishi has more instructions, so learn Mitsubishi and learn Siemens' week ...

Mitsubishi FR-A840 series inverter is coming "strong". Mitsubishi FR-A840 series inverter is coming "strong".

Mitsubishi Electric Automation Corporation has launched the A800 Series Integrated Inverter Drive (VFD) for fast, reliable, easy-to-use, and easy integration and installation for occupational demand drives. The A800 series variable frequency drive combines traditional induction and permanent magnet vehicles into a single solution that supplies ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top