Misunderstanding of inverter selection - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. In order to save power, the inverter is selected

Many manufacturers and salesmen praise how high the power-saving rate of the inverter is, and the user also believes that it is true, and the inverter is selected at a high cost simply in order to save electricity, but the results are greatly disappointed.

Whether or not a frequency converter can save power is determined by the type of load it drives. For fans and pump loads, the energy-saving effect is significant after the inverter is selected, while for the constant power load and constant torque load, the energy-saving effect is much worse, and even cannot save electricity.

                                 Misunderstanding of inverter selection - Reynolds

2. The inverter selection is determined by the rated power of the motor nameplate

There is a certain theoretical basis for selecting the inverter based on the rated power of the motor, but in many actual situations on the spot, the motor operation is too large, or the motor is overloaded, so that the inverter selection is either too large, resulting in economic waste, or the inverter selection is too small, resulting in motor damage or inverter explosion.

More on that
Inverter acceleration and deceleration mode selection Inverter acceleration and deceleration mode selection

The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows. 1. Linear form The form makes the inverter ...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system

From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.

The role of frequency conversion technology in work equipment - Reynolds The role of frequency conversion technology in work equipment - Reynolds

Because inverters are widely used, there are many differences in the corresponding types and specifications. We are broadly divided into two categories: voltage and current. The current type of inverter products is characterized by the use of a large inductor as the energy storage link in the middle DC link, and the reactive power will be buffered by this inductor. ...

The factor that causes the breakdown of the inverter – Reynolds The factor that causes the breakdown of the inverter – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage formed due to various reasons exceeds the additional voltage, which is concentrated in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

How to control the torque of the inverter vector according to the system - Reynolds How to control the torque of the inverter vector according to the system - Reynolds

A brief introduction to the progress of the inverter in terms of torque: This function adds the output voltage of the inverter so that the output torque of the motor is proportional to the square of the voltage, so as to improve the output torque of the motor. Improve the skill of insufficient torque at low speed output of the motor, and use the "vector manipulation" ...

Faulty inverter – Reynolds inverter Faulty inverter – Reynolds inverter

In ancient times, there were ten major tortures, which made people unable to survive and die, and experienced the purgatory of the world; Today, there are ten "tortures" of inverters, and the same can make your inverters suffer. Let's follow the editor to find out which of the top ten "tortures" will make your inverter "worse than dead"! ...

Reynolds soft starter problem solving Reynolds soft starter problem solving

1. The soft starter does not start and the fault-free code appears, perhaps because the control power supply is not connected, the solution is to check the power supply of the control power supply to see if the circuit connection is correct. 2. The motor starts when the motor announces a hum/no start signal, perhaps because of the thyristor/module ...

Features of electronic single-phase current transmitter – Reynolds Features of electronic single-phase current transmitter – Reynolds

Single-phase current transmitter is a kind of electric power test substation developed for the power measurement of single-phase communication in motor experiments on the basis of motor experiment and testing technology research, in accordance with IEC and relevant national specifications for motor experiments. The use of advanced filtering technology, reasonable software algorithms, ...

Reynolds inverter FAQ - parameter class Reynolds inverter FAQ - parameter class

1. What are the factory parameters of inverter rehabilitation? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...

Rated current analysis of inverter leakage circuit breaker Rated current analysis of inverter leakage circuit breaker

The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...

Reynolds drive safety rules and warnings Reynolds drive safety rules and warnings

The high-voltage inverter has been designed with the safety of the user in mind. However, due to the energy storage capacitor installed inside the power unit of the inverter, it may still carry a high voltage after disconnecting the power supply, and some parts generate a lot of heat, so contact is prohibited. When working on or near the inverter, please ...

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Advanced technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system can actively adjust according to the set pressure.

Precautions for the coordination of PLC and inverter - Reynolds Precautions for the coordination of PLC and inverter - Reynolds

Under the current production conditions, when the inverter is used to form an automatic control system for control, in many cases, it is necessary to choose PLC and inverter to match the use, such as bearing cleaning, packaging paper printing, PCB board production, etc. PLC ...

Overheating failure light on start-up analysis - Reynolds Overheating failure light on start-up analysis - Reynolds

(1) Frequent starting, resulting in excessive temperature, causing overheating maintenance of soft starter. (The number of starts of the soft starter should be controlled to no more than 6 times per hour, especially for heavy loads) (2) During starting, ...

Advantages of frequency converters over soft start – Reynolds Advantages of frequency converters over soft start – Reynolds

(1) The starting torque is large and the power factor is high. Because the power factor of the motor is related to the working frequency, the power factor under the power frequency power supply is much lower than that under the low-frequency power supply when the motor is running at low speed. The inverter can control the motor from low frequencies and ...

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

Indicator of Reynolds inverter cabinet wiring Indicator of Reynolds inverter cabinet wiring

Voltage level: The voltage level should match the voltage level of the power supply and motor to ensure electrical safety and normal operation of the equipment. Current level: The current level should match the rated current of the motor to ensure electrical safety and normal operation of the equipment. Cable Specification: Cable ...

Fault signal of the frequency converter - Reynolds frequency converter Fault signal of the frequency converter - Reynolds frequency converter

There are three types of fault signals for the inverter: (1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top