PLC control belt conveyor soft start method - Delta

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Belt conveyor is a kind of continuous conveyor, which is one of the most important types of stationary or escorted cranes. The belt conveyor is a continuous conveyor equipment that uses friction to convey the dynamics, and uses belts, steel belts, steel fiber belts and chemical fiber belts as a kind of adaptability and traction operations for conveying materials and traction operations. The soft-start installation of the belt conveyor is operated by a PLC system to stop the control, braking and operation stop control. PLC (Programmable PLC Controller, abbreviation: PLC) control system has the following functions:

                               PLC control belt conveyor soft start method - Delta

1. The PLC can calculate the actual load at that time according to the sum of the load current of the drive motor when the belt conveyor stops each time. When starting again, PLC can choose how many motors are needed when the belt conveyor starts, and choose the starting closure table that is more suitable for this load, that is, the combination of the motor starting acceleration stage, so that the drive motor outputs the appropriate torque, and ensures that the conveyor starts smoothly according to the acceleration required by the plan, and the closure table can be calculated according to the formula, and can also be stored in the PLC in the form of a table.

2. The current gauge is selected to switch the starting resistance of the drive motor by a one-time maintenance method to ensure that the reliable start can be stopped under various load conditions.

3. The shutdown process of the belt conveyor can also be suspended, so that the shutdown characteristics can be satisfied with the planning and pleading, and the impact of the conveyor during the shutdown process can be reduced. The electrical backstop feature is planned on the uplink conveyor to prevent the conveyor from slewing and rolling when the conveyor is stopped with load. In the degree of large inertia, the belt conveyor uses DC energy consumption braking skills, cooperates with the adjustment of the rotor resistance of the motor, and controls the braking characteristics of the belt conveyor.

4. Complete the software-based drag system control. The selection of PLC control and binary resistance planning makes the control of the motor starting process have a certain adaptability to the load change. The softwareization of a large number of jobs can reduce the amount of debugging work, improve the sensitivity of correction work, and make parameter correction convenient.

5. On the side of the delivery system composed of multiple belt conveyors, the PLCs of each belt conveyor are connected to each other through the communication network to form an advanced control system. The communication network completes the mission of instruction transmission, data exchange, operation status monitoring, etc.

More on that
Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

Rated current design of inverter leakage circuit breaker - Delta Rated current design of inverter leakage circuit breaker - Delta

1. Install AC reactor and DC reactor. When the capacity of the inverter is greater than 500kva in the distribution transformer, and the transformer capacity is more than 10 times the capacity of the inverter, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...

Delta's servo motor maintenance and safety measures Delta's servo motor maintenance and safety measures

Delta's servo motor system is planned for industrial use, and it is necessary to have a sufficient understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and equipment, and to ensure that the motor can be used correctly, please read this safety precaution carefully before installing the machine. ...

Delta NT series UPS industrial power supply Delta NT series UPS industrial power supply

Delta's NT series UPS is a high-power UPS carefully discussed by experts for large-scale users, and a number of advanced skills have been selected, which can be used for various data processing systems, telecommunications systems, satellite systems, network systems, medical equipment, safety and emergency escape equipment, monitoring and security systems, and various industrial systems.

Delta's inverter product model Delta's inverter product model

Delta's VFD inverters have established extensive brand awareness in industrial automation stores. Each series of products is designed for different operating needs such as torque, loss, overload, overspeed operation, etc., and is adjusted according to the characteristics of different industrial machinery; It can provide customers with a variety of choices, and a wide range of ...

The principle of Delta's inverter inverter The principle of Delta's inverter inverter

As far as I know, since the advent of active induction motors, there has been a variable frequency operation in the way of communicating generators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the decrease in the speed of the generator ...

Identify the problem area of the inverter - Delta Identify the problem area of the inverter - Delta

In the process of inverter protection and maintenance, various problems are often encountered, such as field line problems, poor primary parameter settings or mechanical equipment shortcomings. If there is a defect in the inverter, how to distinguish which part of the problem is a little more detailed here. ...

Delta's inverter process setting Delta's inverter process setting

1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...

The output of the inverter is not short-connected to the power frequency The output of the inverter is not short-connected to the power frequency

1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly 2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.

How does Delta inverter adjust the frequency? How does Delta inverter adjust the frequency?

  Delta's frequency modulator frequency modulation is mainly operated on the control panel, and the process: 1. Press the Menu button to enter the parameter programming menu,   ​   2,P0.01=1,Enter this parameter to complete the correction frequency of the panel button, ...

The peripheral equipment of the inverter governor - Delta The peripheral equipment of the inverter governor - Delta

When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless ...

Delta's inverter method to reduce the failure rate Delta's inverter method to reduce the failure rate

Daily inspection item 1 of Delta's inverter problem repair: Check whether there are any abnormal changes in the sound of the motor during operation, including whether there is vibration during the operation of the motor. Routine inspection item 2 of Delta inverter problem repair: Check out the inverter installation environment is ...

Regular diagnosis and repair method of Delta servo motor Regular diagnosis and repair method of Delta servo motor

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

Common problems of VFD control motors - Delta Common problems of VFD control motors - Delta

Question 1. Why use a VFD to control the motor? Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...

Selection of braking resistors for Delta inverters Selection of braking resistors for Delta inverters

1. The necessity of braking resistance If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage. Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...

Precautions for long-term idle use of Delta inverter Precautions for long-term idle use of Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: 1. After the equipment is powered on, it becomes ...

How to quickly master Delta servo? How to quickly master Delta servo?

  1: What is the difference between servo motor and general motor? The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic steel sheet, so that it can be produced by the stator coil.

Features of two-phase electric fan inverter - Delta Features of two-phase electric fan inverter - Delta

With the continuous development of science and technology, there are more and more types of domestic machinery and equipment, and the upgrading of equipment is getting faster and faster. So what are the characteristics of two-phase electric fan inverter and whether it is worth choosing for enterprises. ...

Repair of Delta inverter problemsView items Repair of Delta inverter problemsView items

Daily inspection item 1 of Delta's inverter problem repair: Check whether there is any abnormal change in the sound of the motor during operation, including whether oscillation occurs during the operation of the motor. Delta's daily inspection of inverter problem repair ...

The principle structure of low-voltage circuit breaker - Delta The principle structure of low-voltage circuit breaker - Delta

Low-voltage circuit breakers, commonly known as active air switches, are one of the primary electrical switches in low-voltage distribution networks. It can not only turn on and off normal load current, motor operation current and overload current, but also turn on and off short circuit current. It is mainly used as a low-voltage distribution line or a switch cabinet that is not often operated ( ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top