Rittal products are divided into:
Rittal control cabinets: small enclosures (polycarbonate enclosures PK, junction enclosures KL, compact control enclosures EB, bus enclosures BG), compact control enclosures, plastic control enclosures KS, enclosure systems (subdivided into TS 8/SE 8 family), parallel enclosure systems TS 8, freestanding system enclosures SE 8, IT enclosures/enclosures (divided into network/server enclosures TS IT, distributor enclosures, IT enclosures), piano console systems/PC cabinet systems (divided into TOP piano consoles TP, single-inclined vertical console TP, universal piano console, PC cabinet system), operating cabinet/support arm/vertical system (divided into comfortable operation panel, Optipanel, operation cabinet with decorative handle, compact operation panel, support arm system, vertical system), stainless steel cabinet (divided into junction box KL, bus cabinet BG, compact control cabinet AE, parallel cabinet system TS 8, independent system cabinet SE 8, PC cabinet system, operation door cabinet), explosion-proof cabinet.
Power distribution components: bus system (divided into Min-PLS, Riline), Ri4Power (divided into bus system Maxi-PLS, Flat-PLS, cover system, functional compartment configuration, Ri4Power accessories, Ri4Power ISV distribution cabinet)
Temperature control systems: TopTherm filter fan, TopTherm top mounted fan, Top mounted fan, top exhaust fan, rack mounted fan for 482.6 mm (19), rack mounted fan Vario for 482.6 mm (19), cross-flow fan for 482.6 mm (19), air/air heat exchanger are all part of the category of air/air heat exchangers
Cooling device (divided into semiconductor air conditioner, wall-mounted air conditioner, top-mounted air conditioner, door air conditioner), liquid cooling (divided into air/water heat exchanger, liquid cooling cabinet (LCP), water cooler), cabinet heater (divided into 10 – 150 W continuous heating power without fan, 235 – 800 W continuous heating power with fan)
IT Infrastructure : RiMatrix S, IT Cabinet Systems/Enclosures, IT Power Distribution (IT-Power), IT Cooling (IT-Cooling), IT Monitoring (IT-Monitoring),
Software & Services: Planning & Project Management, Design, Calculations, Validation, Component & System Technology, Virtual Control Cabinet Installation, Control Cabinet Fabrication
System Expansion: Flex-Block Base System, Base, Base Plate, Wall Plate, Rack Consolidation Technology, Door/Lock, Top Cover, Internal Expansion, Cable Routing, 19 (482.6mm) Expansion Technology, Handles, Attachments, Front Mounting, Monitor, Keypad, Pallets and Drawers, Connectors, Signal Mount.
|
More on that
|
Rittal Cables – an introduction to the performance of industrial control cables
Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.
|
|
Rittal cables – type descriptions for power cables
The model of the power cable
1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...
|
|
Presentation of the features of the Rittal cabinet TS8 seismic kit
Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.
|
|
Rittal toroidal transformers Primary connection 115 V/400 V
Rittal toroidal transformer primary connection 115 V/400 V
Product Model: 3201.970
Power supply for wall-mounted air/water heat exchangers in 230 V sizes. A 115 V or 400 V main connector is available.
Product Description: Wall for 230 V Specification
|
|
Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis
1. The circuit breaker cannot be closed
Causes:
1. The undervoltage coil does not work (the voltage is normal). Solution: Replace the undervoltage coil.
2. Press the closing button, and the closing coil will not work when it is powered up. Solution: Replace the undervoltage coil.
3. Cooperation...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)
41. Can power lines be divided into according to the erection method?
A: Overhead power lines and cable lines.
42 What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...
|
|
Rittal Cables – precautions for the installation and wiring of control cables
Precautions for the installation and wiring of control cables:
1. Under the eaves. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures, and it is recommended to use pipes. Ultraviolet (UV) – Do not apply cables without UV protection to direct sunlight rings ...
|
|
Rittal cables - the key points for the purchase of wires and cables
1. Look at the packaging, the wires of the national standard are often better, neat, and have a sense of quality when you hold them.
2. To open the package and take a look at the wires inside, the wire requirements of the national standard wire 1.5——-6 square are required to be skin thickness (insulation thickness) is 0.7mm, and too thick is non-standard.
|
|
How to set the temperature of the Rittal air conditioner
1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters.
2. High temperature alarm: ...
|
|
Rittal cables – the meaning of the first letter of the number of the control cable
First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This cable can transmit data signals and has a certain resistance to wear and chemical corrosion, so ...
|
|
Rittal cabinets – the specifications of server cabinets
Server cabinets have requirements in terms of depth, height, and load-bearing capacity. There are three heights of 2.0 meters, 1.8 meters and 1.6 meters; The width is 800mm, 700mm or 600mm; There are three depths: 700mm, 800mm and 900mm.
Can be configured: special fixed pallet, special ...
|
|
Rittal Cables – an introduction to the process characteristics of cables
1. The impact of large-length continuous superposition combined production mode on the production of wires and cables is global and controllable, which involves and affects:
(1) Production process and equipment layout
All kinds of equipment in the production workshop must be reasonably discharged according to the process flow required by the product, ...
|
|
A detailed assortment of Rittal products
Rittal's products are: Rittal control cabinets: small cabinets (polycarbonate cabinets PK, junction boxes KL, compact control boxes EB, bus cabinets BG), compact control cabinets, plastic control cabinets KS, cabinet systems (subdivided into TS 8/SE 8 family), parallel cabinet systems...
|
|
Rittal Rittal economy air conditioning, RBT cooling unit
Rittal has an economical air conditioner on the market, and the Rittal RBT cooling unit – is your most economical choice! If a limited budget makes you more interested in the cost
Extremely sensitive, then RBT is the ideal choice for you
Choose. Produced through large-scale assembly lines, as well as cold
But the unit itself is excellent ...
|
|
Rittal cabinets – precautions for high and low voltage distribution cabinets
1. The elevation or verticality of the distribution box (panel) exceeds the allowable deviation: it is caused by inaccurate measurement and positioning or uneven ground, and should be corrected in time.
2. The iron frame of the distribution box is not square: the iron frame is not straightened and aligned before the installation of the iron frame, or the position of the fixed point is deviated during installation.
|
|
Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets
1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear.
Structural features
...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
How much is the external design of domestic power distribution equipment products?
Answer: Front panel type, cabinet type and box type, but also indoor type, fixed type and component fixed assembly, some products use drawer cabinets.
Transmission circuits?
Answer: Erected in the power plant step-up substation and ground ...
|
|
Rittal cabinets – solutions for cooling network cabinets
1. Deliver the cold air to the network cabinet: Because the equipment in the cabinet needs the air conditioning the most.
2. Deliver the cold air to the front of the network cabinet: because the cold air can only enter the module server chassis from the front of the server to play a role in heat exchange.
3. Precisely adjust the ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is Peak Load? What is trough load? What is Average Load?
A: Peak load refers to the maximum load that can occur on the grid and the user in a day. The trough load is the hourly average of the least amount of usage that occurs in the grid and the users in a single day.
|
|
Rittal cables – common causes of cable failure
1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...
|
|