RittalAs a commonly used box in Rittal, many users do not understand the material and structure of this series of boxes.
Now I would like to introduce the Rittal explosion-proof enclosure
Apply:
– Zones 1 and 2 or Zones 21 and 22 according to 94/9/EG
– Ambient temperature range: -30°C... +80°C
– Degree of protection according to EN 60 079: Protects the equipment inside the enclosure by increasing its safety performance
Material:
– Cabinet: stainless steel 1.4301
(AISI 304)
– Lid: stainless steel 1.4301
(AISI 304), surrounded by foamed silicone resin
– Cabinet: brushed, grit 240
IP65 degree of protection in accordance with IEC 60 529
– Degree of protection IP 66
Scope of supply:
–Box
– Box lid
Certificate:
– PTB 03 ATEX 1013U
– IEC Ex PTB 09.0033U
Authentication:
– ATEX
– IEC
Technical details:
|
More on that
|
What you need to pay attention to when choosing a Rittal-like cabinet and a Rittal-like electrical cabinet
In recent years, Rittal cabinets have been increasingly used in important equipment and projects at home and abroad. This brand from Germany Rittal cabinet has always been a tall image in the industry, the fine quality is fascinating, and the high price makes us prohibitive. With the agility of China's manufacturing industry...
|
|
Rittal's edge data centres inject new momentum into the digital development of enterprises
At the China International Information and Communication Exhibition (PT Exhibition) in Beijing, Rittal is showcasing its innovative "edge data center" solutions. In an era of increasing demand for high-speed processing and maximum flexibility, small, flexible edge data centers are digitizing enterprises in a steady stream of ...
|
|
Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets
1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear.
Structural features
...
|
|
Causes and solutions of low-voltage distribution cabinet alarms
1. It is not displayed at that time. Solution: Check whether the sample signal cable is not connected.
2. Whether the fuse core of the controller in the cabinet is burned out. Solution: Remove the burned out fuse core and replace it with a new one.
3. The voltage of the distribution cabinet is too high, and the overvoltage alarm. Workaround: Re...
|
|
Air conditioner shows H1 fault code solution – Rittal
1. The air conditioner displays the H1 fault code - the reason
When the outdoor temperature is low and the humidity is high, the heat exchanger of the outdoor unit will be frosted after the air conditioner runs for a period of time, then the automatic defrost function will be activated, and the heating operation will be temporarily stopped for 5-10 minutes. Air conditioner heating defrost shows H1 which is normal ...
|
|
Rittal cables – the key point of TPE technology in wire and cable
1. TPE material has soft touch, high elasticity, mild texture, adjustable surface gloss and fog brightness, low smoke and halogen-free, phosphorus-free, excellent oil resistance, weather resistance, aging resistance, flex resistance, ozone resistance and chemical resistance.
2. The old TPE material can be simply recycled and recycled.
|
|
What do you need to pay attention to when wiring your Rittal cabinet – electrical control cabinet?
1. About the electrical part:
1. The input side and output side of the miniature circuit breaker are inverted.
2. The voltage of the coil of the electrical parts does not match the voltage of the drawing, especially the voltage of the small relay and indicator light is easy to error.
3. The positive and negative polarity of electrical appliances is reversed, and the internal polarity of DC electrical appliances is reversed.
|
|
What are the main problems in the practical application of Rittal cabinet air conditioners on the client?
Through continuous big data analysis of 200,000 cabinet air conditioners installed and operated on the market, Rittal found that the main problems in the actual application of air conditioners on the client are as follows:
1. Lack of maintenance, resulting in clogged air conditioner filters, which in turn causes the air conditioner to stop running or ...
|
|
Rittal outdoor cabinet + temperature control solutions for you to provide comprehensive protection
Rittal's outdoor cabinet + temperature control solution provides 1+1 >2 business value, combining the demands of "function and safety" into one, and guarding it in one stop. Whether it's wind, rain, lightning erosion, scorching sun exposure or blizzards, Rittal outdoor system solutions can be used all the way ...
|
|
Rittal cabinets – what are the installation specifications for the cabinets?
1. The host, storage equipment, and server cabinets should be partitioned and arranged, and the host, storage equipment, server cabinets, UPS power supplies, precision air conditioners and other equipment should be set aside for maintenance according to product requirements, and the maintenance interval overlaps with adjacent equipment;
2. Enter the equipment in the computer room in stages.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the types of electric shocks?
Answer: Direct electric shock, indirect contact electric shock, induced voltage electric shock, lightning electric shock, electrostatic electric shock.
What are the organizational measures to ensure safety when working on electrical equipment?
Answer: work ticket system, operation ticket system, inventory site and comprehensive ...
|
|
Rittal at the Hannover Messe 2022 in Germany
"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...
|
|
What are the common cable management methods for Rittal cabinets – network cabinets?
1. The network cabinet distribution frame is fixed in place, the panel paper is loaded into the distribution frame on the front, and the tray is installed on the back.
2. Positioning of the cable management board, the direction of the cable management board should be determined before threading when positioning the cable management board, so that the cable management board does not need to twist the direction in the process of line management, and it can enter the ...
|
|
Rittal cables – measures to prevent or mitigate electrical interference
1. One spare core of the control cable is grounded
It has been proved in practice that when a spare core in the control cable is grounded, the amplitude of the interference voltage can be reduced to 25%-50%, and the implementation is simple, and the cost of the cable is increased very little.
2. Serious consequences will occur when electrical interference is generated.
|
|
Rittal air conditioner alarm code parsing
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
Rittal cables – safety requirements for cables
1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m.
2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...
|
|
Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it
A01--- Rittal cabinet control cabinet door opens
View: Look at the door switches in the Rittal cabinet.
Solution:
(1) Adjust the position of the door switch.
(2) Check whether the wiring method is correct (passive normally closed point at 1.2 points).
A03 --- Filter Monitor ...
|
|
Rittal Cables – the principle of selection of power cables
1. Selection of wire and cable models
When selecting wires and cables, it is necessary to consider the use, laying conditions and safety; For example, depending on the application, power cables, overhead insulated cables, control cables, etc. can be selected
According to the different laying conditions, the general plastic insulated cable can be selected ...
|
|
What are the advantages of Rittal enclosure processing – sheet metal cabinets?
The development of sheet metal cabinet and chassis processing industry is getting bigger and bigger, which is due to the rapid development of society, the popularity of high-tech products, server cabinets, computer main chassis, equipment shells, etc. What are the advantages of sheet metal cabinet enclosures?
1. Cabinet and chassis products provide space for ...
|
|
What is the difference between a control cabinet and a distribution box?
One. The nature is different
Distribution box: There is a large amount of parameter data in the distribution box. It generally constitutes a low-voltage distribution box.
Control cabinet: The control cabinet is to assemble the switch cabinet, measuring instruments, protection devices and auxiliary equipment in a closed or semi-enclosed metal cabinet or screen according to the requirements of electrical wiring.
|
|