What are the components of an electromagnetic flowmeter?

Create Date: 2024-8-30 12:03:23|Source: Fuji Electric/Fujielectric

The electromagnetic flowmeter is roughly said to be composed of two parts: a sensor and a converter, and the form of the flowmeter can be divided into two types: integrated and split.

The detailed rules say that it is mainly composed of a magnetic circuit system, a measuring catheter, an electrode, a lining, a shell and a converter.

The connection between the sensor and the pipe of the electromagnetic flowmeter includes flange connection, snap-on connection and butt welding connection. There are 7 electrode materials (316L stainless steel, Hastelloy B, Hastelloy C, tantalum, titanium, platinum, tungsten carbide), and 5 lining materials (neoprene CR, PTFE F4 (PTFE), polyperchloroethylene propylene F46 (FEP)\polyurethane rubber PU, Teflon (PFA))
What are the components of an electromagnetic flowmeter?


More on that
What are the key points for setting the PID function parameters of the inverter? What are the key points for setting the PID function parameters of the inverter?

Take Fujifilm's FRENIC-VP (F1S)/MEGA (G1S) series inverters as an example: J01 PID control function activation. J01=0: PID does not operate, the inverter does not set the PID function or uses external PID adjustment. J01=1: PID positive action (negative feedback). J01=2: PID Reverse ...

Inverter control cabinet application – Fuji Electric Inverter control cabinet application – Fuji Electric

Introduction to the main products and functions 1.1 Water supply frequency conversion cabinet (1) Ordinary water supply frequency conversion cabinet: this product can control a water pump motor frequency conversion water supply and a water pump motor power frequency water supply at the same time, and the power of the water pump motor is between 0.75KW and 5.5KW. The water supply capacity of the product can meet the needs of ...

Achieve industry-leading low loss and expand the discrete IGBT XS series product line Achieve industry-leading low loss and expand the discrete IGBT XS series product line

Fuji Electric Corporation (headquartered in Tokyo, Japan, President Mitsuhiro Kitazawa) is pleased to announce the addition of a 1200 V rated voltage to its discrete IGBT*1 XS series line, providing industry-leading low losses. As the world moves closer and closer to achieving a low-carbon society, ...

Fujifilm Portable Ultrasonic Flow Meter - Water Supply Company Site Check Pump Room Flow Application Fujifilm Portable Ultrasonic Flow Meter - Water Supply Company Site Check Pump Room Flow Application

Fujifilm portable ultrasonic flowmeter is used to check the flow rate at the outlet of a water pump in the field Error analysis in the flow measurement process Check for abnormal readings from the in-line flow meter Avoid process interruptions and the background of more expensive tube opening costs Waterworks are mainly used to treat water, and generally have the following processes.

Fuji Electric high-efficiency, energy-saving, safe medium frequency induction furnace Fuji Electric high-efficiency, energy-saving, safe medium frequency induction furnace

Since 1963, we have produced more than 2,000 induction furnaces, including: 85T/60T groove type induction furnace for cast iron, 40T crucible type induction furnace for cast iron, 60T copper alloy crucible type induction furnace and other largest product records in Japan, the largest market share in Japan. ...

Can ultrasonic flowmeters be used in the production and processing of edible oil? Can ultrasonic flowmeters be used in the production and processing of edible oil?

Can a small flow ultrasonic flow meter be used for flow measurement of soybean oil? There are several steps in the processing of edible oil that require the use of flow meters to measure the volume and weight of how much oil flows out of the pipeline. Enterprises that produce and process edible oil need to be aware of the crude oil and ...

Analysis of common causes and preventive measures of inverter failures - Fuji Electric Analysis of common causes and preventive measures of inverter failures - Fuji Electric

1. Analysis of common faults in the main circuit The main circuit is mainly composed of three-phase or single-phase rectifier bridges, smoothing capacitors, filter capacitors, IPM inverter bridges, current limiting resistors, contactors and other components. Many of these common faults* are caused by electrolytic capacitors. The life of an electrolytic capacitor is mainly determined by the ...

Fuji Electric Systems Co., Ltd. will release the EX100 series mini uninterruptible power supply system Fuji Electric Systems Co., Ltd. will release the EX100 series mini uninterruptible power supply system

Fuji Electric Systems Co., Ltd. will release the Fuji Mini UPS EX100 Series on October 5, 2010. This is a new series of high-efficiency uninterruptible power supply systems (UPS) with capacities ranging from 1kVA to 3kVA. Fuji Electric ...

Irrigation area remote monitoring water flow operation management scheme Fujifilm ultrasonic flowmeter application Irrigation area remote monitoring water flow operation management scheme Fujifilm ultrasonic flowmeter application

In order to solve the problems of inaccurate metering and billing, difficult collection of water charges, and serious waste of water resources in agricultural irrigation water, modern automatic control, radio frequency triggering and other technologies are used to achieve the goal of paying the fee before using water, charging according to the quantity, automatic metering, and automatic opening and closing of the pump.

Precautions for Fujifilm servo motors in use Precautions for Fujifilm servo motors in use

Fujifilm servo motor has many precautions in use, and the following is a brief introduction   Fujifilm servo motors can be used in places where water or oil droplets are attacked, but they are not completely waterproof or oil-resistant. Therefore, servo motors should not be placed or used in water or oil environments. If you serve ...

Introduction to the application case of Fujifilm ultrasonic flowmeter in power plant flow measurement Introduction to the application case of Fujifilm ultrasonic flowmeter in power plant flow measurement

Due to the outstanding technical application advantages of Fujifilm ultrasonic flowmeter, Fujifilm ultrasonic flowmeter has been widely concerned in various fields such as power plant flow measurement, which can be reflected from the following application cases. Circulating water flow is measured in hydropower plants ...

The industry and demand are integrated to accelerate the expansion of new areas The industry and demand are integrated to accelerate the expansion of new areas

With the proposal of "Made in China 2025" and the increasing role of science and technology in promoting new industries, the automation industry has begun to pick up, and the inverter market has regained its vitality and vitality after the downturn in the first two years. As a world-renowned provider of electrical automation products and systems, Fujifilm ...

Current status and outlook of Fuji Electric power semiconductors Current status and outlook of Fuji Electric power semiconductors

Based on the management policy of "contributing to the realization of a sustainable society in the energy and environment business," Fuji Electric is working to address social and environmental issues including global warming by promoting the SDGs throughout its corporate activities, including its supply chain. To achieve this purpose, the improvement of the ...

【In-depth Interpretation】Cybersecurity of Safety Instrumented System (SIS). 【In-depth Interpretation】Cybersecurity of Safety Instrumented System (SIS).

When a company begins a Safety Instrumented System (SIS) project, the first decision stakeholders must make is to choose the system architecture. By complying with international cybersecurity standards such as IEC 62443 (ANSI/ISA 62443 series of standards) as well as international process industry automation users...

Several commonly used sewage treatment detection instruments Several commonly used sewage treatment detection instruments

We usually pay attention to the whole sewage treatment industry, and the sewage treatment detection instrument that plays a great role in sewage treatment, I believe that there must be little attention, today Xiaobian sorted out several commonly used sewage treatment detection instruments, I hope it will be helpful to you. 1. Ultrasonic level gauge ...

Zhijian ∣ Chinese and Japanese experts decode the key technology of lithium battery lamination winding machine industry Zhijian ∣ Chinese and Japanese experts decode the key technology of lithium battery lamination winding machine industry

With the use of lithium batteries as power sources in mobile phones, digital products, laptops, electric toys, military industry, new energy vehicles, portable medical equipment and other fields, the domestic lithium battery industry has developed rapidly. As an important part of lithium battery manufacturing equipment, the market of lamination winding machine ...

Launched EGCS laser gas analyzer to support marine systems business Launched EGCS laser gas analyzer to support marine systems business

Fuji Electric Corporation (headquartered in Tokyo, Japan; President: Mitsuhiro Kitazawa) announced the official launch of its laser gas analyzer for EGCS to support the marine systems business. 1. Background To reduce emissions of sulphurs (SOx, substances that can cause air pollution), the International Maritime Organization ...

Fuji Electric - Precautions for inverter maintenance Fuji Electric - Precautions for inverter maintenance

In the summer, in terms of the inverter that is indispensable for equipment control and speed regulation, the scorching weather is the hard injury of the inverter's heating. A large number of existing studies and practices show that the failure rate of the inverter will increase with the increase of temperature, the service life will decrease with the increase of temperature, and the ambient temperature will rise.

Inverter control motor leakage causes and measures Inverter control motor leakage causes and measures

The cause of the leakage problem We all know that the three-phase stator winding of the motor flows through the current to produce a rotating magnetic field, according to the principle of magnetoelectric induction, the shell of the motor will produce an induced electromotive force, the size of this electromotive force depends on the size of the switching frequency of the inverter IGBT, due to the high ...

Fuji Electric fault codes and how to deal with them Fuji Electric fault codes and how to deal with them

Fuji Electric inverter inverter fault code fault code fault after the corresponding treatment method is given.   OC alarm. Keyboard board LCD display: add, subtract, constant speed overcurrent. For the OC alarm with high current in a short time, under normal circumstances, there is a problem with the current detection circuit of the driver board, and the module may also ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top