A brief introduction to Delixi leakage circuit breaker

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi leakage maintainer is mainly when the electrical equipment leakage problem to provide maintenance of the device, when the installation of leakage maintainer, should be other devices overcurrent maintenance device. When the fuse is used for short-circuit maintenance, the selection of its standard should be compatible with the on-off of the leakage maintainer. Leakage circuit breakers, which combine leakage maintenance devices with power switches (active air circuit breakers), are now widely used, and this new type of power switch has the performance of short-circuit maintenance, overload maintenance, leakage maintenance, and undervoltage maintenance. The wiring is simplified, the size of the electrical box is reduced and it is easy to manage.

                               A brief introduction to Delixi leakage circuit breaker

The significance of the nameplate model of Delixi leakage circuit breaker is as follows: attention should be paid to the use, because the leakage circuit breaker has multiple protection functions, when the occurrence of tripping, the fault factors should be specifically distinguished: when the leakage circuit breaker is broken due to short circuit, the cover must be opened to see whether the contact is seriously burned or pitted; When tripping due to line overload, it cannot be closed from the beginning immediately.

Because the circuit breaker is equipped with a thermal relay as an overload maintenance, when the additional current is presented, the bimetal sheet bends to separate the contacts, and it is necessary to wait for the bimetal sheet to cool down and recover to its original state before the contacts can be closed from the beginning. When tripping due to leakage problems, it is necessary to find out the factors and eliminate the faults before closing from the beginning, and it is forbidden to forcibly close. When the leakage circuit breaker breaks and trips, the L-like handle is in the middle position, and when it is closed from the beginning, it is necessary to pull the operating handle down (breaking direction) first, so that the operating mechanism is re-buckled, and then close upward.

The leakage circuit breaker can be used for switching appliances with large capacity (greater than 4.5kw) power line and infrequent operation. Plastic shell circuit breakers are divided into air circuit breakers and leakage circuit breakers, and there are generally three types: with short circuit and overload maintenance functions. It has the function of leakage maintenance. It has the functions of short circuit, overload and leakage maintenance. Leakage refers to the single-phase leakage of the line after the switch to the switch, and the additional leakage current switch will jump, and then play a maintenance role.
More on that
Voltage regulator failure and solution - Delixi Voltage regulator failure and solution - Delixi

1. There is no output, no voltage indication or no start when the machine is turned on. Overvoltage or undervoltage maintenance 1. Adjust the internal output voltage adjustable potentiometer 2. The wrong phase and the lack of phase are maintained, and the two phases are arbitrarily replaced by three phases 3. The main control circuit board is broken 3. Replace 4. The output AC has been ...

Delixi circuit breaker insulation accident Delixi circuit breaker insulation accident

The circuit breaker insulation incident can be divided into the internal insulation terminal and the external insulation incident. The hazards caused by internal insulation incidents are generally greater than those of external insulation. (1) Internal insulation incidents The internal insulation end is mainly a bushing and a current transformer ...

Delixi circuit breaker model difference Delixi circuit breaker model difference

CDB1 miniature circuit breaker is a kind of current-limiting high-breaking miniature circuit breaker with double protection of overload and short circuit, which is suitable for AC 50Hz, rated voltage 400V and below, rated current 63A and below circuits, as line overload and short circuit protection, can also be used under normal circumstances.

Delixi bearing rust causes Delixi bearing rust causes

1. The instantaneous high temperature in the grinding process will make the surface of the workpiece reach a molten state, and the steel surface will react with the oxygen in the air chemically, which will form a very thin (20-30nm) iron oxide film.

Delixi single-phase inverter CDI-EM60 series manual Delixi single-phase inverter CDI-EM60 series manual

Read this statement carefully before installing, operating, maintaining, and viewing the EM60 series drives. In order to ensure the safety of your person, equipment and property, please be sure to read carefully before using our EM60 series inverter.

Delixi selects the rated parameters of the contactor Delixi selects the rated parameters of the contactor

According to the controlled target and operating parameters such as voltage, current, power, frequency and operating system, the additional parameters of the contactor are determined. 1) The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. But for the sake of the party ...

Delixi AC contactor fault causes and solutions Delixi AC contactor fault causes and solutions

First, the iron core may not be able to suction power Causes: The power supply voltage is too low or fluctuates too much, the power supply capacity of the operating circuit is lacking or the wire is broken and the control contact is poor, the technical parameters of the coil are inconsistent with the application conditions, and the product itself is damaged. Solution: Turn up the power ...

Delixi voltage regulator capacity and size calculation method Delixi voltage regulator capacity and size calculation method

1. Single-phase circuit single-phase power supply - power supply with a single AC electromotive force. The fundamental power supply method for civil electricity. Single-phase load – A load that is powered by a single-phase power supply. Household appliances such as lights, televisions, and electric fans are generally single-phase loads. The accounting method is as follows: a. When negative ...

Delixi voltage regulator working principle Delixi voltage regulator working principle

In Delixi voltage regulator, the voltage correction from and under voltage conditions is performed through two basic operations, namely Oersted and step-down operation. These operations can be switched on and off manually or automatically by electronic circuits. Under voltage conditions, the voltage of the boost operation is increased to the rated voltage.

The cause of the abnormality of the motor controlled by the inverter The cause of the abnormality of the motor controlled by the inverter

The first method is that you can analyze what the cause is according to the condition displayed on the inverter, such as whether the faulty code appears normal, whether there is still running code or not, and still nothing appears (in the case of input power), which means that there is a rectification problem. If you're on standby...

The principle of circuit breaker jumping, closing and holding circuit - Delixi The principle of circuit breaker jumping, closing and holding circuit - Delixi

During opening and closing operations, the remote opening and closing command is usually a high-level pulse of several hundred milliseconds. In order to prevent the pulse from becoming invalid before the end of the opening and closing operation, and to ensure that the opening and closing operation is completed, a holding circuit is added. Intuitively, it is to avoid tripping and closing, and the exit contact precedes the DL ...

How to select Delixi voltage regulator How to select Delixi voltage regulator

1. For pure resistive loads such as incandescent lamps, resistance wires, electric furnaces and other equipment, the power of the voltage regulator should be 1.5 times the power of the load equipment - 2 times that of the load equipment, for example, if your electric furnace is about 250W, you can choose a voltage regulator with a power of 500W. 2. Rationality ...

LDO low dropout linear regulator features - Delixi LDO low dropout linear regulator features - Delixi

Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...

Delixi inverter load type Delixi inverter load type

The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

Causes and solutions for circuit breaker closing failure - Delixi circuit breaker Causes and solutions for circuit breaker closing failure - Delixi circuit breaker

1. Failure analysis. 1) Closing fuse, control fuse blowing or poor contact. 2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker. 3) The DC voltage is too low. 4) Closing and locking action. ...

Delixi switching regulator basics Delixi switching regulator basics

1. What is a switching regulator? Switching voltage regulators, some people call it regulators, voltage regulator sources. Complete voltage regulation, is the demand control system (negative feedback), from the automatic control theory we know that when the voltage rises, it will be lowered through negative feedback, and when the voltage drops, it will be ...

Delixi EM60 series inverter to factory settings Delixi EM60 series inverter to factory settings

First, the process of inverter rehabilitation factory value 1. Study the manual and find the corresponding function number, or key combination. 2. Confirm that the parameters can be corrected (sometimes the inverter will set the parameter to write the protection function in order to prevent the parameters from being changed randomly, and the password must be guaranteed to enter the correction) ...

The difference between circuit breaker and disconnector - Delixi The difference between circuit breaker and disconnector - Delixi

The disconnector is a kind of switching equipment that is mainly used for "blocking the power supply, reversing the operation, and connecting and blocking the small current circuit", without arc extinguishing function. When the barrier switch is divided into directions, there is an insulation distance between the contacts that meets the specified requirements and a significant disconnection mark; When in the azimuth, it can carry ...

Frequently asked questions about Delixi voltage regulators Frequently asked questions about Delixi voltage regulators

Delixi voltage regulator will have a stable preset amplitude of a fixed output voltage, regardless of its input voltage or load conditions change. There are two types of voltage regulators: linear and switched The linear regulator is an active (BJT or MOSFET) operated by a high-gain differential amplifier ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top