The principle of circuit breaker jumping, closing and holding circuit - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

During opening and closing operations, the remote opening and closing command is usually a high-level pulse of several hundred milliseconds. In order to prevent the pulse from becoming invalid before the end of the opening and closing operation, and to ensure that the opening and closing operation is completed, a holding circuit is added. Intuitively speaking, in order to avoid the tripping and closing outlet contact being disconnected before the DL auxiliary contact, resulting in incomplete tripping and closing action, the tripping and closing self-insistence loop is added. See the blue part of the figure for details. HBJ and TBJ separate represent the latching relay that closes and trips, and S1 represents the travel node of the energy storage spring.

  ​                         The principle of circuit breaker jumping, closing and holding circuit - Delixi

During the closing operation, the HBJ Delixi relay is turned over, and the HBJ normally open contact is closed. At this moment, regardless of whether the closing outlet contact is disconnected or not, the closing circuit will be connected through the HBJ contact to complete the closing operation. At this moment, whether the closing outlet contact is disconnected before the DL auxiliary contact will not affect the circuit breaker closing. It's the same as a brake failure.

However, there is a downside to adding HBJ relays. After the closing command HBJ is activated, the opening and closing of the closing circuit is completely determined by the auxiliary contact DL. If the spring does not store energy and the circuit breaker cannot be normally closed, the normally closed contact of the DL will always be closed, and the closing current will always exist, which is easy to burn HQ. Therefore, the travel node S1 of the energy storage spring should be connected in series.

More on that
Precautions for the use of Delixi stabilized power supply Precautions for the use of Delixi stabilized power supply

1. The use environment of regulated power supply requires good ventilation, no moisture, no corrosive gas, explosive substances, conductive dust Egypt steam, etc., and it is required to be installed in places without intense oscillation. ​ 2. The voltage regulator is used according to the function of the electrical equipment.

Delixi inverter use characteristics and applications Delixi inverter use characteristics and applications

Delixi inverter is a kind of inverter with both high quality and stability, it has excellent function and strong function, widely used in manufacturing, construction industry and energy conservation and environmental protection areas. Let's take a look at some of the characteristics and uses of Delixi inverter. ...

Why is the operation of the inverter energy-efficient? - Delixi Why is the operation of the inverter energy-efficient? - Delixi

The inverter lowers the output frequency to reduce the speed of the motor, taking the conditioning air volume as an example. By reducing the air volume, power consumption can be significantly reduced. Why is the operation of the inverter energy-efficient? According to fluid mechanics, power = pressure× flow, flow ...

Analysis of common problems of Delixi inverter Analysis of common problems of Delixi inverter

1. Is it possible to put the motor directly into a fixed frequency inverter without using soft start? It is possible at very low frequencies, but if the given frequency is high, the conditions for direct starting of the power supply are similar. A large starting current (6-7 times the rated current) will flow too much, due to ...

A brief introduction to Delixi leakage circuit breaker A brief introduction to Delixi leakage circuit breaker

Delixi leakage maintainer is mainly when the electrical equipment leakage problem to provide maintenance of the device, when the installation of leakage maintainer, should be other devices overcurrent maintenance device. When the fuse is used for short-circuit maintenance, the selection of its standard should be compatible with the on-off of the leakage maintainer. Appear...

Delixi circuit breaker protection features Delixi circuit breaker protection features

Quickness: It means that the maintenance device should be able to remove the short-circuit fault as soon as possible, and its purpose is to improve the stability of the system, reduce the damage to the faulty equipment and lines, reduce the scale of the fault, and improve the effect of active reclosing and active investment of standby power supply or standby equipment. Reliability: Refers to ...

Delixi surge protector knowledge quiz Delixi surge protector knowledge quiz

Many people don't know what a surge is, surge is also known as a surge or lightning protection maintainer, the first is to maintain the household electrical equipment when it rains and thunders to avoid being damaged by lightning, and when the lightning strikes high-voltage electricity is drained to the ground through the surge maintainer, it will not directly hit the electrical equipment ...

The difference between Delixi single-phase and three-phase AC voltage regulators The difference between Delixi single-phase and three-phase AC voltage regulators

Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on. ...

Delixi reduces the number of inverter maintenance times Delixi reduces the number of inverter maintenance times

Inverter is a very widely used equipment in the modern factory, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delixi voltage regulator fault phenomenon and solution Delixi voltage regulator fault phenomenon and solution

Voltage regulator fault phenomena and their corresponding solutions Input phase loss - correctly input phase A, B, C phase, should be three-phase four-wire system or five-wire system The control circuit board is not working - the control circuit board is disconnected or damaged by itself. Repair or replace Control circuit board in the state of protection ...

Delixi inverter all aspects of the selection of precautions Delixi inverter all aspects of the selection of precautions

The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...

Delixi power transformer protection role Delixi power transformer protection role

In most large electrical systems, generators and power transformers are the two most expensive pieces of equipment. In addition to the capital cost of purchase, the continuity and reliable operation of these two key equipment systems are also the most critical. For example, the test ...

Delixi takes you to understand the knowledge of resistance and resistivity Delixi takes you to understand the knowledge of resistance and resistivity

1. Resistance Indicates the magnitude of the conductor's resistance to the current. Conversion between units of resistance: 1KΩ=1000Ω R indicates the resistance, and the unit of resistance is: ohms (Ω) R=U/I U--- voltage (unit: volts V) I--- current (in ...

Analysis of the reasons why the maintenance of Delixi frame air switch can not be closed Analysis of the reasons why the maintenance of Delixi frame air switch can not be closed

The low-voltage air circuit breaker is the primary equipment for low-voltage power distribution, and it should be able to operate reliably when the electrical equipment is no-load, load-loaded or short-circuited. Its primary function is to maintain the line and equipment, can turn on, carry and break the current under normal circuit conditions, and can also be used in the specified non-...

Using a soft starter to misconception - Delixi Using a soft starter to misconception - Delixi

In the use of soft starters, some users often have some faulty concepts such as: 1. It is thought that whether the motor can start successfully is related to the function of the soft starter, and a good brand or even a foreign brand should be selected under heavy load. 2. When the motor is not ...

Delixi solid state relay introduction Delixi solid state relay introduction

What is a Solid State Relay Solid State Relay (SSR) is a pointless switch composed of microelectronic circuits, discrete electronic devices, and power electronic power devices. The barrier between the control end and the load is completed by a barrier device. The input of the solid state relay is micro...

Servo motor failure analysis - Delixi Servo motor failure analysis - Delixi

Three-phase communication servo motors are widely used, but after long-term operation, various problems will occur. Timely identification of the cause of the fault and corresponding treatment is an important task to prevent the spread of the fault and ensure the normal operation of the equipment. One...

Delixi circuit transformation attention to detail Delixi circuit transformation attention to detail

1. If strong electricity and weak electricity are to be separated by a long distance from the horizon walking line, the interval should generally exceed 30 cm to prevent disturbance and be interspersed with each other. 2. In order to facilitate the future line change, the PVC pipe must be cut down and straightened as much as possible.

Delixi voltage regulator problem repair Delixi voltage regulator problem repair

1. The output voltmeter is constantly swinging back and forth, and sparks are generated at the carbon brush 1. The contact pressure between the carbon brush and the coil plane is too small 2. The carbon brush is severely worn 1. Clean the coil and carbon brush with a fine file or sandpaper, and then adjust the carbon brush pressure 2. Replace the carbon brushes with new ones ...

The main factor affecting the poor heat of the instrument - Delixi The main factor affecting the poor heat of the instrument - Delixi

The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different samples are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top