According to the controlled target and operating parameters such as voltage, current, power, frequency and operating system, the additional parameters of the contactor are determined.
1) The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage.
2) The operating frequency of the motor is not high, such as compressors, pumps, fans, air conditioners, punches, etc., and the additional current of the contactor is greater than the additional current of the load. The type of contactor can be selected Delixi CDC10 communication contactor, etc.
3) Counterweight mission motors, such as machine tool main motors, lifting equipment, winches, crushers, etc., have an average operating frequency of more than 100 times/min, and can be used for CJl0Z and CJl2 contactors when running in starting, jogging, forward and reverse braking, reverse braking, etc. In order to ensure the electrical life, the contactor can be used to reduce the capacity. When selected, the additional current of the contactor is greater than the additional current of the motor.
4) For the heavy mission motor, such as printing press, boring machine, etc., the operation frequency is very high, up to 600-12000 times/h, often running in the starting, reverse braking, reverse and other conditions, the contactor can be roughly selected according to the electric life and starting current, and the contactor type is CJl0Z, CJl2, etc.
5) When the capacitor in the communication loop is put into the grid or removed from the power grid, the contactor selection should consider the closing inrush current of the capacitor. Generally, the additional current of the contactor can be selected by 1.5 times the additional current of the capacitor, and the type is selected Delixi CDC10 communication contactor.
6) When using a contactor to control the transformer, the size of the inrush current should be considered. For example, communication arc welding machine, resistance welding machine, etc., generally can be selected according to 2 times the additional current of the transformer, the type of Delixi CDC10 communication contactor, etc.
7) For electric heating equipment, such as resistance furnaces, electric heaters, etc., the cold resistance of the load is smaller, so the starting current is correspondingly larger. When selecting the contactor, it is not necessary to consider (starting current), and can be selected directly according to the additional current of the load. The type can be selected Delixi CDC10 communication contactor, etc.
8) Due to the large starting current of the gas discharge lamp, the starting time is long, about the control of the lighting equipment, the communication contactor can be selected according to the additional current 1.1-1.4 times, and the type can be selected Delixi CDC10 communication contactor.
9) The additional current of the contactor refers to the maximum promised current of the contactor under long-term operation, the duration is ≤8h, and it is installed on the open control board, if the cooling conditions are poor, when the contactor is selected, the additional current of the contactor is selected according to 110%-120% of the additional current of the load. In the case of motors that operate for a long time, the oxide film has no chance to be removed, which increases the contact resistance, causing the contact to heat up beyond the promised temperature rise. In practice, the additional current of the contactor can be reduced by 30%.
|
More on that
|
Introduction of molded case circuit breaker - Delixi
Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...
|
|
Analysis of the quality of Delixi surge protector
Look at the quality of the surge protector, to see whether it can complete his basic specification, relative to the surge protector of the primary specification is whether the surge operating voltage can be constrained below the required value, the surge protector must discharge the lightning current when the mission is completed, this specification must be completely completed.
|
|
Delixi fan and pump load frequency conversion selection
Delixi general fan, pump, the requirements for the inverter are simple, only the inverter capacity is equal to the motor capacity. Roots blowers, deep-water pumps, sediment pumps, and fast-changing musical fountains are available in a larger capacity.
Lifting...
|
|
AC contactor controls the forward and reverse rotation of the motor - Delixi
The forward rotation control of the asynchronous motor, the peers of the double contactor and the button are doing more, but is there anyone who will use an AC contactor to achieve the forward rotation control effect of the motor?
Practical application: general bench drill, letter ...
|
|
Delixi low-voltage AC contactor can not be suction reason
AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...
|
|
Delixi product parameter unit VF and V difference
Voltage vf and v difference: The two have different meanings, vf on the battery represents the feedback voltage, while v represents the capacity of the battery, which is the unit of measurement of voltage. Lithium battery is a kind of battery with lithium metal or lithium alloy as the positive/negative electrode data and the use of non-aqueous electrolyte solution.
...
|
|
Precautions for the use of Delixi stabilized power supply
1. The use environment of regulated power supply requires good ventilation, no moisture, no corrosive gas, explosive substances, conductive dust Egypt steam, etc., and it is required to be installed in places without intense oscillation.
2. The voltage regulator is used according to the function of the electrical equipment.
|
|
The role of Delixi inverter
1. It can reduce the impact on the power grid, and there will be no problem of excessive peak-to-valley difference.
2. It can speed up the controllable function, and then speed up the slipping according to the needs of the user;
3. The abort mode of the motor and equipment is controllable, ...
|
|
Delixi control transformer use precautions
Delixi control transformer use of the most types is BK, JBK, BKC and other types, these transformers use some precautions as follows:
1. Before purchasing, please estimate the total capacity of the electrical appliances you use.
|
|
Delixi leakage circuit breaker identification method
1. Appearance
Genuine Delixi switch shape is more fashionable, looks elegant and beautiful, and the surface is neat, impact resistance is relatively strong, will not briefly crack or yellow.
And most imitations will turn yellow after a period of use...
|
|
The difference between linear regulator and switching regulator - Delixi
The switching voltage regulator is a different kind of regulated power supply from the linear voltage regulator, and its circuit types mainly include single-ended flyback, single-ended forward, half-bridge, push-pull and full-bridge.
The difference between it and the linear power supply is that the transformer in the circuit does not work at the power frequency, but at the power frequency.
|
|
Delixi occasion to choose the inverter
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, the output of the inverter should be fully considered ...
|
|
Delixi voltage regulator safety precautions
1. When the stabilized power supply is powered on, please do not disassemble the stabilized power supply or pull the input and output cables of the stabilized power supply at will to prevent electric shock or other electrical safety accidents.
2. The input and output connections of the regulated power supply must be reasonably arranged, ...
|
|
Delixi inverter uses the keyboard to set the frequency step
Delixi inverter parameter check setting steps
Using the keyboard to set the frequency, we can use the keyboard number direct setting and the keyboard potentiometer setting two methods, and the control method can be selected by modifying the parameter P0.01.
...
|
|
The reason for the instability of the voltage regulator output - Delixi
It shows that the voltage regulator base is not voltage corrected, and the voltage regulator in this situation is like a transformer, the higher the input voltage, the higher the output voltage, the input decreases and the output voltage also decreases.
This...
|
|
Delixi inverter controller data instability solution
Problem depiction:
The data of Delixi inverter controller is unstable, and sometimes there is a deviation, how to deal with it?
Solution:
This is the result of severe disturbance of the controller. Often the controller ...
|
|
What are the main series of Delixi switches
1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black.
2 ...
|
|
Delixi parameter voltage regulator performance and advantages
1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...
|
|
The difference between an isolation switch and a circuit breaker
The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position.
Isolate ...
|
|
Delixi DZ47sGQF self-resettable over/undervoltage protector
In order to meet the needs of business development, Delixi Electric newly upgraded to create DZ47sGQF Navigator series of self-resettable over- and under-voltage protectors, the new products have a leading technology platform, better performance and quality, can completely replace the old product DZ47GQF.
...
|
|