The McgsPro architecture is divided into three parts: configuration environment, simulated operation environment, and operation environment.
The configuration environment and the simulated operating environment are equivalent to a complete set of tools and software, which can be run on a PC. Users can cut down the content according to their practical needs. It helps users to plan and structure their own configuration projects and to perform utility tests. The operating environment is an independent operation system, which carries out various processes in accordance with the way specified by the top user of the configuration project, and completes the objectives and functions of the user's configuration planning. The operating environment itself has no meaning, and it must be used as a whole together with the configuration engineering to form a user system. Once the configuration operation is completed, and the configured project is downloaded to the operating environment of the lower computer through the manufacturing U disk package or Ethernet, the configuration project can leave the configuration environment and run independently on the lower computer. Then, the reliability, real-time, certainty and safety of the control system are completed.
The structure of the user application system generated by McgsPro is composed of five parts: the main control window, the equipment window, the user window, the real-time database and the operation strategy. A window is a piece of space on the screen, a "container" that is directly available to the user. In the window, the user can place different components, create graphic targets and adjust the layout of the picture, and configure different parameters to complete different functions.
There can be multiple user windows and multiple operational strategies in McgsPro, and there can also be multiple variables in the real-time database. McgsPro uses the main control window, the equipment window and the user window to form a human-computer interactive graphical interface of the application system, and configures and equips various targets or components of different types and functions, which can be visualized and processed in real time.
The main control window structures the main structure of the application system, determines the overall summary of the engineering operation in the industrial control, as well as the operation process, menu commands, characteristic parameters and engine characteristics, etc., and is the main structure of the application system.
The equipment window is an important part of the McgsPro configuration software, which establishes the connection relationship between the system and the external hardware equipment in the equipment window, so that the system can read data from the external equipment and control the operation status of the external equipment, and complete the real-time monitoring of the industrial process.
The user window completes the "visualization" of data and processes, and three different types of drawing targets can be placed: primitives, dynams, and animated artifacts. Primitives and Dynamo Targets provide users with a complete set of ways to plan and produce graphic images and animations. Animation components correspond to different animation functions, and they are commonly used animation display and operation modules summarized from engineering practice experience, which can be directly used by users. By placing different graphical targets in the user window and building multiple user windows, the user can structure a variety of complex graphical interfaces and complete the "visualization" of data and processes in different ways.
It is recommended that users do not add more than 1,000 user windows.
The real-time database is the center of the McgsPro system, which is equivalent to a data processing center, and also plays the role of a common data exchange area. McgsPro uses a real-time database in its own file system to manage all real-time data. Real-time data collected from external devices is fed into the real-time database, and data from other parts of the system is also fed into the real-time database. The real-time database automatically completes the alarm processing and storage processing of real-time data, and it also sends relevant information to other parts of the system in the form of things as needed, so as to trigger related things and process them in real time. Therefore, the unit stored in the real-time database is not only the numerical value of the variable, but also the characteristic parameters (characteristics) of the variable and the operation method of the variable (alarm characteristics, alarm processing, and storage processing, etc.). This kind of data that encapsulates values, characteristics, and methods together is called a variable. The real-time database uses goal-oriented technology to provide services for other parts and provide data sharing for various functional components of the system.
The operation strategy is a means of useful control over the end of the system operation process, and is a structure of the system supply, in which the strategic condition components and the "strategic line" composed of the strategic components are placed, and the system can operate the real-time database in accordance with the set order and conditions, control the opening of the user window, close and determine the operation status of the equipment components, etc., and then complete the control of the operation process of the external equipment.
An operational system has three fixed operational strategies: the launch strategy, the back-office task, and the exit strategy. The launch strategy is called at the beginning of the operation of the application system, the background tasks are called by the background of the system in the operation process independently and regularly, and the exit strategy is called when the application system exits the operation. The user strategy is called up by other components of the system. In McgsPro, 300 operational strategies are supported.
To sum up, an application system consists of five parts: the main control window, the equipment window, the user window, the real-time database and the operation strategy. At the beginning of the configuration operation, the system only builds an empty structure for the user that can operate independently, and provides a rich number of animation parts and functional parts. If you want to complete a practical application system, you should mainly complete the following tasks:
First of all, it is necessary to use the component structure application system supplied by the system or extended by the user in the configuration environment to form a project with rich functions and practical applications.
Then, the configuration results from the configuration environment are downloaded to the operating environment. The operating environment and the configuration results together constitute the user's own operating system.
|
More on that
|
Common Problems and Solutions of Kunlun MCGS Touch Screen(11-19)
11. Meaning of split time in save data browsing
It refers to defining according to one's own needs the point in time from which yesterday and today are separated, or the month, etc.
12. The history table cannot display the extracted data
(1) Extract first, and then use the history table to display the data ...
|
|
What is the difference between Config King and Kunlun Tongstate?
Point issues, run time.
1. The point limit of the configuration king development version is more troublesome for larger engineering trial configuration, and you can only buy the development environment to do it. Kunlun Tongtai is provided for free with unlimited points, you can confidently configure your project without worrying about the number of points.
|
|
Kunlun Tongtai touch screen - the advantages of wireless resistance touch screen
1. Compared with the four-line touch screen, the five-line touch screen has a longer service life and can withstand more than 30 million clicks. The lifespan of a four-wire resistive touch screen is 3 to 4 years, while the average of a five-wire resistive screen can reach 6 years.
2. Once the industrial display of the four-wire touch screen is touched...
|
|
Common Problems and Solutions of Communication of Kunlun Tongtai MCGS Touch Screen(66-69)
66. Mitsubishi PLC: How to choose the driver for programming port communication
Mitsubishi PLC programming port is 422 communication, and Mitsubishi FX series programming port is selected; The 232BD is driven by Mitsubishi FX series programming port; The 485BD is driven by Mitsubishi FX series serial port.
67. Mitsubishi PLC: Programming port parameter setting ...
|
|
Kunlun Tongtai touch screen - classification and working principle of capacitive touch screen
Classification of capacitive touch screens
Capacitive touch screens are divided into two categories, one is surface capacitive touch screen, and the other is projected capacitive touch screen, and projected capacitive can also be subdivided into self-capacitive and mutual capacitive. Among them, the surface capacitive and projected self-capacitive touch screen can only achieve ...
|
|
Kunlun Tongtai touch screen - the advantages of surface acoustic wave touch screen
1. The optical performance is the best. The clarity and light transmittance are the highest, the reflection is the least, and there is no color distortion, this is because the sound wave screen body is pure glass, unlike the resistive screen with multiple layers of composite film; The capacitive screen is coated with a layer of film on the surface, and the light transmittance is worse.
2. Anti-scratch and anti-barbaric use ...
|
|
Kunlun Tongtai touch screen - the data processing process of capacitive touch screen
After receiving the touch signal, the capacitive touch screen converts the touch data into electrical pulses and transmits it to the touch screen control IC for processing. The signal is amplified by a low-noise amplifier (LNA), then converted and demodulated by analog-to-digital ratio, and finally sent to a DSP for data processing.
Electricity...
|
|
Kunlun Tongtai touch screen - the treatment method of black screen of industrial touch screen
1. Check whether the power supply of the host is working normally. First, check whether the host system is powered by checking whether the power indicator on the host chassis panel is on and whether the power supply fan is rotating. Secondly, use a multimeter to check whether the external voltage meets the requirements, the voltage is too high or too ...
|
|
Steps to upload the program on the Kunlun touch screen
1. Install the MCGS configuration software on the computer first, then find the power supply to supply power to the touch screen, connect the screen with the computer with the communication cable, and upload it in the software.
2. After we install the software, first go to open the software, and then in the drop-down option of the file menu, select ...
|
|
Common problems and solutions of communication of Kunlun Tongtai MCGS touch screen(56-60)
56. Does TPC support OPC communication?
No, the network version supports OPC communication.
57. 200PLCLC communication wiring with TPC7062K
(1) The 7 positive and 8 negative of the TPC RS485 interface is connected with the positive and 8 negative of the PLC serial port 3, and the wiring diagram is as follows:
TPC PLC
58. 200 ...
|
|
Introduction to the main performance and parameters of MCGS Kunlun Tongtai touch screen TPC7062TI
1. Processor: Intel Celeron J1900 quad-core processor, frequency 2.0GHz, stable and reliable performance.
2. Operating system: Support Windows, Linux and other operating systems, and provide pre-installed software (such as remote monitoring software).
3. Display: 7 inch T...
|
|
Common problems and solutions of communication of Kunlun Tongtai MCGS touch screen(47-55)
47. There are very few drivers in Device Manager
(1) Whether to select "All Driver Installation" when configuring the software installation, if not, you need to reinstall the driver;
(2) If you don't find a supported driver in the device window of the configuration software, check whether the device supports the standard ...
|
|
Kunlun Tongtai touch screen - analysis of common fault phenomena of surface acoustic wave touch screen
Fault 1: Touch deviation
Phenomenon: The position of the finger does not coincide with the mouse arrow.
Analysis: After installing the driver, there was no vertical touch to the bullseye center position when correcting the position. Solution: Recalibrate the position.
Fault 2: Touch ...
|
|
Introduction to Kunlun Tongtai configuration software
Kunlun General Configuration Software is a very professional general configuration software. It has full Chinese visualization effects, supports progressive color adjustment, rotation animation effects, and supports temperature control curves and many other industrial control curves, compatible with a full range of Kunlun hardware products, which can save users a lot of time.
|
|
Kunlun Tongtai touch screen - the technical difficulties of infrared touch screen
Ambient light factor, infrared receiver tube has a working range between minimum sensitivity and maximum illumination, but touch screen products can not limit the range of use, from the dark cabaret room to the outdoor use under the high-intensity sunlight on Hainan Island, as a product, it must adapt.
Rapid detection ...
|
|
Kunlun Tongtai touch screen how to set the English window
Open Kunlun Tongtai touch screen programming software and select the [Multi-language Configuration] icon in the edit menu
In the pop-up Multi-Language Configuration window, select File and click Open.
In the Multi-Language Configuration file drop-down menu, select Select Language.
...
|
|
Kunlun Tongtai touch screen - technical parameters of four-wire resistive touch screen
Screen structure: ITO Film is attached to ITO Glass, and is isolated by DOT points in the middle
Outlet cable: integrated with the panel
Connector: 2.54mm pitch socket, standard AMP87499-9
Touch media: fingers, gloved hands, pens, credit cards, etc
...
|
|
Why can't Kunlun touch screen TPC1061Ti communicate directly with S7-300MPI?
Problem Description:
Why can't Kunlun touch screen TPC1061Ti communicate directly with S7-300MPI?
Solution(s):
1. According to the Kunlun Tongtai and Siemens 300MPI direct connection sample, the communication status is 1, ask customer service, check line 3 8 PLC --7 8 ...
|
|
How to maintain the Kunlun Tongtai touch screen
1. Wipe the phone screen with a dry cloth before turning it on every day.
2. Drinks or water droplets falling on the screen will cause the software to stop reacting. This is due to the fact that water droplets and fingers have similar properties, and it is necessary to wipe them.
3. Kunlun Tongtai MCGS screen program can be automatically ...
|
|
The solution to the touch failure of the industrial touch screen
1. Check the wiring port: first check whether the wiring interface is loose, and then check whether the serial port conflicts with the interrupt number. If a conflict occurs, adjust resources to avoid it. Check the surface of the industrial touch screen again for cracks, and replace it in time if so. At the same time, inspect the surface of the industrial touch screen ...
|
|