11. Meaning of split time in save data browsing
It refers to defining according to one's own needs the point in time from which yesterday and today are separated, or the month, etc.
12. The history table cannot display the extracted data
(1) Extract first, and then use the history table to display whether the data is set to save the cycle, whether the data connection is correct, when using the save data extraction, the time interval and the extraction interval should be set reasonably, otherwise the data can not be extracted normally;
(2) See whether the data source and storage target are set correctly, and after the time setting is reasonable, it should be run for a period of time. Data can only be displayed when data is available in the MDB database.
13. How to save data to an SQL database
(1) General version: extract the archived data into SQL through the archive data extraction component: select the ACCESS database file automatically generated by the project as the data source, export the data to the ODBC database, and select the SQL database (first create the database and data table in SQL Server);
(2) Network version: directly select the save database as SQL database in the "Database Connection Settings" under the file menu.
14. Does MCGS have access to Oracle data?
Yes, the prerequisite is that the Oracle client software is successfully installed.
15. The online version of the project runs and exits slowly
The built-in database of MCGS software is the ACCESS database, and the ACCESS database itself is a small database, the database file is more than 50M, and the amount of data saved is too large, which will cause the database to crash and cause the project to run slowly. We recommend that you use SQL databases to store data or delete data periodically.
16. Use Internet Explorer browser to browse the web version of the project
(1) LAN internal IP browsing network version project:
A.The default port number of MCGS network version is 80, generally as long as the IP address of the network version of the machine can be directly pinged on the client machine, and the IP address of the network version server can be entered in the IE column on the client machine, you can browse directly;
B. If port 80 is bound by other addresses, you can set the port number under the "HTTP Parameters" attribute under the "Main Control Window", so that the port number should be added when browsing in IE before you can browse.
(2) Access a PC running network version in the LAN through the external network, first map the port bound by the network running network version of the internal network to the public network through the LAN, and map out the 1966 port of the PC. Take ADSL dial-up Internet access as an example to give a brief introduction:
Install the peanut shell software on the server and enter the requested free domain name, such as mcgsjn.givp.net
Configure the router (e.g. TP-LINK):
A goes to the dynamic DNS setting and binds the domain name;
B: Go to Virtual Server in Forwarding Rules and set the following settings:
ID: Service Port, IP Address, Protocol, Status
1 3100 200.200.200.11 TCP takes effect
2 1966 200.200.200.11 TCP takes effect
C. Run the network version of the project on the PC and enter the address in the IE column of the external networkhttp://mcgsjn.givp.net:3100 /defaul .htm, you can access the Internet.
17. How to repair engineering damage
(1) You need to install the ACCESS database in the OFFICE office software;
(2) Close the configuration project, right-click the project, open the way / select the program / Microsoft Office ACCESS, OK;
(3) Prompt: convert/open the database, select Open Database (Note: You cannot choose to convert the database, the converted project is not recognized), prompt security warning, select Open;
(4) After opening the ACCESS database, select the menu Tools/Database Utilities/Compress and Repair Database, and then you can repair the project;
(5) If the project cannot be repaired by using the above methods, it means that the project is seriously damaged and needs to be reconfigured.
18. How to achieve landscape printing
In the extended properties of the user window property settings, change the Window Viewport Size of the print window to the size of the printed paper, and select Print Landscape.
19. Can the script driver be used in the general version?
Yes, but you will need to use a generic custom environment. Customized environments are availablewww.mcgs.com.cn Download the script-driven development tool in the "Download Center - Customized Version", and there is a customized environment for the network version in the script development kit.
|
More on that
|
Kunlun Tongtai MCGS communication problem solution
1. How to check the communication status of the device in MVGS
Among all non-board devices (except for some customized devices) of MCGS, *** channels are communication channels. That is, after entering the runtime environment, after the device driver starts working, the ...
|
|
Kunlun Tongtai touch screen - the advantages of surface acoustic wave touch screen
1. The optical performance is the best. The clarity and light transmittance are the highest, the reflection is the least, and there is no color distortion, this is because the sound wave screen body is pure glass, unlike the resistive screen with multiple layers of composite film; The capacitive screen is coated with a layer of film on the surface, and the light transmittance is worse.
2. Anti-scratch and anti-barbaric use ...
|
|
Kunlun Tongtai touch screen - precautions for the purchase of industrial touch screen
First of all, there is touch technology, which is very important. At present, there are three commonly used types of touch technology for touch screens, which are resistive touch screens, capacitive touch screens, and infrared touch screens. Capacitance and resistance can not be made of large size, infrared touch screen can be made of small size, can also be made of large ...
|
|
Kunlun Tongtai touch screen - daily maintenance of large-size infrared touch screen
1. Do not hit with metal objects.
Usually the HMI will be covered with a layer of glass to protect the screen and make it easy to touch. However, the glass is fragile, do not hit the screen with metal objects during use, it is easy to cause the glass to be scratched or broken.
2. Avoid squeezing the screen with heavy objects.
Around HMI ...
|
|
Kunlun Tongtai TPC1062K the fault repair that occurs when the touch screen is touched
1. The touch screen is not allowed to be repaired
If it is the position touched by the finger that does not coincide with the mouse arrow. Then you should install the driver and correct the position without touching the bullseye vertically. and re-correct the position. If you touch some areas accurately ...
|
|
Can Kunlun Tongtai touch screen run in the computer embedded version?
Kunlun Tongtai touch screen is a touch screen controller, which is generally used in embedded systems, such as industrial computers, embedded computers, intelligent terminals, etc. If you want to connect it to your computer to run, you can try the following methods:
1. USB interface: Kunlun Tongtai touch screen ...
|
|
Common Problems and Solutions of Communication of Kunlun Tongtai MCGS Touch Screen(66-69)
66. Mitsubishi PLC: How to choose the driver for programming port communication
Mitsubishi PLC programming port is 422 communication, and Mitsubishi FX series programming port is selected; The 232BD is driven by Mitsubishi FX series programming port; The 485BD is driven by Mitsubishi FX series serial port.
67. Mitsubishi PLC: Programming port parameter setting ...
|
|
Kunlun Tongtai touch screen - three key points of industrial control touch screen all-in-one machine design
Balance, simplicity and coordination are the three key points of industrial touch screen all-in-one design, among which:
Balance: Ensure that all objects on the screen, such as windows, buttons, and slips, have the same style. The size, concave and convex effect of buttons at all levels and the annotation font and font size are consistent, and the color of the button is consistent.
|
|
Kunlun Tongtai touch screen - troubleshooting method of four-wire resistive touch screen
Inaccurate screen position: Repositioning can be done via driver software.
Touch position and screen cursor upside down: When installing the touch screen, the position of the screen is reversed, please adjust the touch screen position according to the principle of right-hand position out.
The touchscreen display icon keeps pointing towards the fixed ...
|
|
Kunlun Tongtai touch screen - the technical difficulties of infrared touch screen
Ambient light factor, infrared receiver tube has a working range between minimum sensitivity and maximum illumination, but touch screen products can not limit the range of use, from the dark cabaret room to the outdoor use under the high-intensity sunlight on Hainan Island, as a product, it must adapt.
Rapid detection ...
|
|
Kunlun Tongtai touch screen - analysis of common fault phenomena of surface acoustic wave touch screen
Fault 1: Touch deviation
Phenomenon: The position of the finger does not coincide with the mouse arrow.
Analysis: After installing the driver, there was no vertical touch to the bullseye center position when correcting the position. Solution: Recalibrate the position.
Fault 2: Touch ...
|
|
Kunlun touch screen IP address view and setting
1) After the above touch calibration is completed, click [Enter Operating System] in the [Startup Properties] dialog box to enter the operating system;
2) Click [Start] --> [Settings] --> [Network & Dial-up Connection];
3) Double-click [DM9000A] to bring up the corresponding dialog box, ...
|
|
How to choose the touch screen model in Kunlun Tongtai software
How to choose the touch screen model in the Kunlun Tongtai software, this is selected according to the model of the touch screen.
Before you can choose a model, you need to determine what type of touchscreen you use on your device. Different models of touch screens, some with high configuration, some with low configuration, but the configuration is ...
|
|
Kunlun Tongtai touch screen - common faults and solutions for touch screen failure
1. There is no response to touch after using it for a period of time
The touch screen will not respond after a period of normal use after being turned on. Touch screen fault analysis and processing are divided into the following three situations:
1) In some applications, due to poor grounding performance, the control box shell will be covered with a large number of ...
|
|
Kunlun Tongtai touch screen - what are the anti-interference countermeasures of PLC and touch screen?
In order to improve the anti-interference ability of the PLC system, we should start from the design. In the anti-interference design of specific projects, products with strong anti-interference ability can be selected to improve the anti-interference of equipment and systems by suppressing interference sources, cutting off or attenuating the transmission path of electromagnetic interference, and using software means.
|
|
Common problems and solutions of communication of Kunlun Tongtai MCGS touch screen (70-80)
70. Omron PLC: Parent device parameter settings
(1) The communication parameter setting of the parent device of the universal serial port should correspond to the communication parameter setting of the PLC serial port, and the default standard parameters of the PLC are set to: 9600, 7, 2, E (even check);
(2) Users can set it according to their needs, and it is recommended to ...
|
|
Kunlun Tongtai touch screen - the working principle of the five-wire resistive touch screen
The five-wire resistive touch panel is composed of two layers:
(1) ITO Glass: A piece of glass or plexiglass is used as the substrate, and the surface is coated with a transparent conductive layer.
(2) ITO polyester plastic layer (ITO Film): The surface is hardened to make the surface smooth and ...
|
|
MCGS Embedded is the main function of the configuration software
MCGS Embedded is the main function of the configuration software
1. Simple and flexible visual operation interface: Adopt full Chinese and visual development interface, which meets the usage habits and requirements of Chinese.
2. Strong real-time performance and outstanding ...
|
|
How to save the MCGS Kunlun Tongtai touch screen when the power is off?
1 Feature Overview
There are two kinds of data saved by MCGS TPC, one is the internal variable data in the MCGS software, and the other is the data obtained from the lower computer device.
2 Functional Points
[1] ...
|
|
How to insert primitives into MCGS Kunlun Tongtai touch screen?
Open Kunlun Tongtai touch screen software, create a new [Window 0], and click to open.
Find the Bitmap icon in the toolbox and click to open it.
After creating a bitmap in Window 0, right-click and select Load Bitmap.
Open the text where the image is saved ...
|
|