Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards the proximity switch, regardless of whether it is a conductor or not, due to its proximity, the dielectric constant of the capacitor must change, so that the capacitance changes, so that the state of the circuit connected to the measuring head also changes, so that the switch can be switched on or off. This proximity switch detects not only conductors, but also liquids and powders that can be insulated.
General details
The switching functions are complementary
Output type PNP
Rated working distance 15mm
The installation is not flush
Output polarity DC
The working distance is guaranteed to be 0 - 10.8 mm
The actual working distance is 13.5 - 16.5 mm
Rating:
Installation conditions
B 15 mm
C 30 mm
F 45mm/60mm
Working voltage: 10-30 volts DC
Switching frequency 0 - 100 Hz
Lag 1 - 10 typical. 5%
Reverse Polarity ProtectionReverse Polarity Protection
Short-circuit protection pulses
Imax≤500 mA
Voltage drop ≤ 2V
The repeatability ≤ 1.5mm
The working current is 0-100 mA
Off-state current 0 - 50 μA typical. 5 microamps
The no-load supply current ≤ 15 mA
Switch status indicator LED, yellow
Functional safety parameters:
MTTFd 941 amps
Mission time (TM) 20 a
Diagnostic Coverage (DC) 0%
Indicator/Operation Keys:
Potentiometer sensitivity adjustment
Licensing & Certification:
UL listed cULus list, generic
CCC certified products with a voltage rating of ≤36 V do not require CCC certification/marking
Surroundings:
Ambient temperature -25-70 degrees Celsius (-13-158 degrees Fahrenheit)
Storage temperature: -40-85 degrees Celsius (-40-185 degrees Fahrenheit)
Mechanical Properties:
Connecting cable connector M12 x 1, pigtail PUR, L=300 mm
Core cross-section: 0.34 mm2
Housing material PBT
Sensing surface PBT
Degree of protection IP67
Tightening torque, housing screws ≤ 1 Nm
The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.
This article introduces the P+F/Double Capacitive Sensor CBN15-F64-A2-0 product, if you are interested in P+F/Double Capacitive Sensor, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
P+F Retroreflective sensor GLV18-55-S/25/102/159
Introduction:P+F Retroreflective Sensor GLV18-55-S/25/102/159 Retroreflective Photoelectric Sensor with Polarization Filter, M18 Threaded Housing Design, Plastic Housing, Side Optical End, 3.5 m Detection Range, Red Light, Bright On, DC Type, NPN Output, M12 Plug ...
|
|
P+F Inductive Sensor NBB8-18GM60-US 8mm
Summary: Inductive proximity sensors are the product of choice for most applications that require the precise and non-contact detection of metal objects in machinery or automation. As a pioneer and market leader in the field of sensors, we offer our customers innovative, high-quality inductors.
|
|
P+F/Inductive sensor NCB1,5-8GM25-N0-Y295009
Introduction: Smooth or threaded stainless steel housing for inductive sensors; reverse polarity protection and short circuit protection; LED status indication; M8, M12 connector connection or terminal wiring; PVC, PUR or silicone cable outlet; 2-wire, 3-wire, 4-wire DC, AC, NAMUR...
|
|
P+F/Capacitive sensor CBN15-30GK60-A0 NPN15mm
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Reflective Plate Photoelectric Switch ML100-55/95/103 360 degree view
Product Description: Retroreflective sensor with polarization filter, plastic housing, 5 m detection range, red light, adjustable sensitivity, on/off when light/dark, DC type, PNP output, M8 plug, compact design, easy to use, extremely bright and clear light spot, all-metal threaded mounting, ...
|
|
P+F through-beam photoelectric sensor OBE10M-18GM60-SE4-V1
Introduction: OBE10M-18GM60-SE4-V1 Thru-beam Photoelectric Sensor Two-color Indication LED; Bright/dark, programmable; Sensitivity regulator to ensure optimal application needs; Degree of protection IP67; Robust cylindrical metal housing M18 x 1.
...
|
|
P+F/Retroreflective Area Sensor RLG28-55 / 115B / 136
Product Introduction: Retroreflective area sensor with 6 beams in a widely used standard photoelectric housing, red light, 4 m detection range, switchable bright/dark, push-pull output, M12 plug, reflective area sensor housing with 6 beams in a standard photoelectric sensor, connector and ...
|
|
P+F/Capacitive sensor CBB8-18GK75-E2-V1 with a diameter of 18 mm
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F inductive sensor NBB20-U1-Z2 flush 20 mm
Description: Inductive sensors are available in smooth or threaded stainless steel housings, reverse polarity protection and short-circuit protection, LED status indication, M8, M12 connector connection or terminal wiring, PVC, PUR or silicone cable outlet, 2-wire, 3-wire, 4-wire DC, AC, N...
|
|
P+F/Encoder RVI58N-*******1 Incremental
Introduction: An incremental encoder provides a fixed number of pulses in one revolution, and the speed is calculated by the number of pulses measured per unit of time. To measure angles and positions, it is common to start counting from a starting reference point. The accuracy of incremental encoders depends on mechanical and electrical factors ...
|
|
P+F Inductive Sensor NBB15-30GM50-E0 15mm
Introduction: P+F Inductive Sensor NBB15-30GM50-E0 15mm flush; Longer working distance; Extended temperature range -40 ... +85 °C; Extended operating voltage range; With a variety of mounting options, it is flexible to use.
...
|
|
P+F/GJF retro-reflective sensor GLV18-55/115/120
Product Description: Retroreflective sensor with polarization filter, M18 threaded housing design, plastic housing, front optical face, 4 m detection range, red light, light and dark on, DC type, 2 PNP output, fixed cable, high-efficiency wire in M18 plastic housing Standard application, very high detection range
|
|
P+F/Capacitive sensor CJ6-18GK-N-Y22734 rated voltage 8V
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Optical fiber optic sensor SU19.1/110/115 30μs
Product Introduction: Classic Series Fiber Optic Sensor with Display, Slave Module, Push-Pull Output, Fixed Cable, Classic Line with Display, AGC (Automatic Gain Control) for Faster Teach-in, Combined Installation, Easy Wiring, Transparency Recognition, 30μs High Speed Mode.
...
|
|
P+F/Sensor NBN4-12GM40-E2-V1 4 mm
Introduction: The inductive sensor is to use electromagnetic induction to convert the measured physical quantities such as displacement, pressure, flow, vibration, etc. into the change of self-inductance coefficient and mutual inductance coefficient of the coil, and then convert the output of voltage or current change by the circuit to realize the conversion of non-electricity to electricity.
...
|
|
P+F/Capacitive sensor CBN15-F64-A2 15mm non-flush
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
Germany P+F/Bejiafu capacitive sensor CBN10-F46-E2-0,4M-V3
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F Capacitive Sensor CJ40-FP-A2-P4 4-wire
Introduction:P+F capacitive sensor CJ40-FP-A2-P4 series rectangular, housing material is POM / metal, output type 4 wires, non-flush mounting, DC voltage type, screw terminal connection type, protection class IP65.
...
|
|
P+F/Retroreflective Sensor GLV18-55/73/120 10~30 V DC
Product Description: Retroreflective sensor with polarization filter, M18 threaded housing design, plastic housing, front optical face, 4 m detection range, red light, light and dark on, DC type, 2 PNP output, fixed cable, high-efficiency wire in M18 plastic housing Standard application, very high detection range
|
|
P+F/Inductive sensor NBB20-L2-A2-V1 flush mounted
Introduction: Smooth or threaded stainless steel housing for inductive sensors; reverse polarity protection and short circuit protection; LED status indication; M8, M12 connector connection or terminal wiring; PVC, PUR or silicone cable outlet; 2-wire, 3-wire, 4-wire DC, AC, NAMUR and AS ...
|
|