The bus system is to directly connect the components to the bus, the bus does not need to be perforated, at this time, the bus is not only the conductor of the component, but also the support of the component, the current can reach 2500A, so that the box transformer function has the following progress: 1 ...
Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...
The 60mm bus system refers to the three- or four-wire bus spacing of 60mm. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the optimal distribution of current intensity levels, ...
(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected. ...
(1) Single bus. Single busbar, single bus segment, single bus plus bypass and single bus segment plus bypass. (2) Tandem bus. Double busbar, double bus segment, double bus plus bypass and double bus plus bypass. (3) Three busbars. Triple bus, triple bus section, triple bus section ...
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...
1. The bus bar is divided into hard bus bar and soft bus bar. 2. According to different shapes, hard busbars can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars, etc. 3. Rectangular busbar is a commonly used busbar. According to its material ...
For the use of Siemens' new 3VA1 series circuit breakers in the 30Compact system with currents up to 160A, Wiener has developed an EQUES® bus adapter. A spring-loaded base and high-performance internal power rails ensure safe connection to the circuit breaker. advantage ...
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...
1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...
1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
The new base system adapter creates a new type of solution in combination with the 185Power system, which was not possible before. CrossBoard® products can be easily connected to the adapter of the base system via the CrossLink® interface. Components of DIN support rails, e.g. fuses ...
The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00 Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar. In the mounting position ...
A new addition to the world of CrossBoard® systems: the MOTUS® hybrid motor starter with IO-Link interface is a new networking feature in the MOTUS® IO-Link family that enables continuous communication between the control and device levels. Control the delivery of instructions, control the parameters ...
Since the launch of the 185Power system in 2014, Wiener has continued to develop new connection technologies and fuse-type disconnector technologies for the 185Power system on the basis of the 185mm bus technology. In addition to the application of 1600A below ...
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation. 2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
Ambient air temperature: turn off the busbar system to benchmark the ambient air temperature; Unless otherwise ruled, the manufacturer should give an additional current to shut down the busbar system at a base ambient air temperature of 35°C; If applicable, the manufacturer should give an additional coefficient k: (K1=1 at 35°C) in order to determine the size of the package.
The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...
The ultimate temperature value-added of the busway is directly related to the current-carrying capacity of the conductor and the potential safety hazards, so it is necessary to mark the limiting temperature value-added of the busway, which is the most critical safety technical parameter of the busway. Follow me...
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...
1. Select the model of the fuse according to the circuit requirements and device conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...
Brand Home
Vernal products
Venal Information
Online Consultation:
Contact: Manager Huang
Contact QQ: 3271883383
Contact number: 13522565663
Weekdays: 9:00-17:00
Holidays: Only emergencies are handled
Contact us
13522565663 (Manager Huang)
3271883383
2nd Floor, Zhuoer Youth Hui Green Hall, Panlong City, Huangpi District, Wuhan City
Wuhan 76 Technology Co., Ltd |Customer Service Hotline: 13522565663|Email:ronglove999@outlook.com
All products on this site are from the official website or the Internet, because there are too many types, only part of it is sent as an example! If there is any violation, please contact to delete!