The default standby time is 1 minute. The specific steps are as follows: 1. First of all, open our touch screen editing software, and be sure to select the software corresponding to the touch screen model. 2. Edit the touch screen screen we need. 3. Open the common menu in the upper left corner ...
1. Plug in the U disk on the touch screen, you don't need to power off the screen, the screen supports the hot-swap function, but at this time, it is best not to communicate with external devices to reduce unnecessary impact. When the screen detects an external device, a dialog box will pop up, select the second Upload Project option ...
1. Copy the required OS to a USB flash drive (FAT32 format is only supported); For example, in the next test, place the OS file in the firmware folder at the root of the USB flash drive. 2. Plug the USB flash drive into the USB host port of the HMI to be updated; 3. Click the arrow in the bottom right corner of the screen ...
1. Omron NJ controller programming 1. The structure data type required for the new project, such as the Boolean switch to be used in this example to create a structure data type of "take-up machine IO", and the integer data used in this example to create a "take-up machine".
1. First of all, open the created Weilun touch screen project, select Common in the menu bar and click Open. 2. Secondly, select the system parameter icon in the common drop-down menu and click to open. 3. Finally, click Change. ...
1. Background color: Right-click on the blank space of the window, select Properties, Pop-up Settings, and select a color in the background; Hatch: In the background, tick the fill, select the pattern color and pattern. 2. Picture/Background Image: Select Picture Element ...
1. Generally, in the lower right corner of the touch screen, there is a small black arrow button, click and enter the correct password, you can enter the system settings. However, when configuring, you can disable this button in the software system settings. 2. Set the system bit LB-9020 in the touch screen to ON...
1. Software editing-system parameter setting-HMI attributes-port number: 8000 change, such as 9000; 2. Bring up the computer task manager - end com_e30.exe under the process; 3. Restart the computer; 4. Query other occupancy on the computer through TCPview software.
Open the created Weilun touch screen project, select [Common] in the menu bar and click Open. In the Common drop-down menu, select the Bit Status Indicator icon and click Open. In the pop-up [New Bit Status Indicator] setting window [General Properties] ...
Virtual serial port configuration process: 1. Open the virtual serial port configuration software and create two pairs of serial ports; 2. The circle is the physical serial port in the computer, and the virtual serial port in the box; 3. Two groups have been added, and friends who want to add port tests can do so in the window on the right.
1. Check the hardware connections: Make sure the touchscreen is properly connected to the device and that all cables and connectors are in working order. Check if the connector is loose or damaged, and if so, reconnect or replace the connector. 2. Check the drivers: Make sure the device is properly installed.
1. Check if the touch screen is clean: If there are stains or grease on the surface of the touch screen, it will cause the touch to be insensitive or slow to respond. The touchscreen surface can be cleaned using a specialized touchscreen cleaner or a clean cloth. 2. Check if the touch screen is damaged: If the touch screen surface is damaged, ...
1. The line interface of the Weilun Tong touch screen is faulty. 2. Whether there is a crack fault on the surface of the touch screen. 3. External interference and control box failure. 4. The connection between the touch screen and the host or the host is faulty. ...
1. The direct window element can realize the bit-address control window pop-up. Setup Steps: 1. Click [Components] in the menu bar - click the "Direct Window" component under [Embed Window]. 2. The dialog box shown in the following figure pops up, specify the "Read Address". ...
USB cable specification: HI-SPEED USB Revision 2.0 SHIELDED 24AWG 1. The USB port of the computer must support standard USB 2.0 or USB 3.0. 2. The USB cable needs to be double-layer isolated: aluminum foil and copper mesh isolation. 3. The length of the USB cable is not ...
1. Connect your Veriton device and open the software to enter the data point configuration page. 2. On the Data Point Configuration page, select the data point that you want to scale. 3. Click the "Settings" button and select "Scale Factor Conversion" in the pop-up window. 4. ...
1. Generally, in the lower right corner of the touch screen, there is a small black arrow button, click and enter the correct password, you can enter the system settings. There are generally three ways to enter the system setting of the TK6070ih touch screen: 1,Generally in the lower right corner of the touch screen, ...
1. Use a red wire to connect the 7 pins of the Rs485 port of the touch screen with the A port of the DTD434MC. Use another black wire to connect pin 8 of the Rs485 port of the touchscreen with the B port of the DTD434MC. 2. The last digit (K88) in the wireless communication terminal setting switch is turned on.
Open the Veriton touch screen programming software, select [Common] in the main interface and open it In the Common drop-down menu, select System Parameters and click Open. Then select [HMI Attributes] in the pop-up system parameter setting menu and click OK. ...
Right-double-click the parameter settings button. Specific steps: 1. Create a new screen, and then make a keyboard, and the OK button is [Screen Jump Control] 2. Double-click the [Parameter Setting] button and select [Properties]. 3. Click [Security], and then ...
Brand Home
Weiluntong products
Weiluntong information
Online Consultation:
Contact: Manager Huang
Contact QQ: 3271883383
Contact number: 13522565663
Weekdays: 9:00-17:00
Holidays: Only emergencies are handled
Contact us
13522565663 (Manager Huang)
3271883383
2nd Floor, Zhuoer Youth Hui Green Hall, Panlong City, Huangpi District, Wuhan City
Wuhan 76 Technology Co., Ltd |Customer Service Hotline: 13522565663|Email:ronglove999@outlook.com
All products on this site are from the official website or the Internet, because there are too many types, only part of it is sent as an example! If there is any violation, please contact to delete!