Reynolds Information SHOW
Frequency converter soft troubleshooting – Reynolds Frequency converter soft troubleshooting – Reynolds

Undervoltage is also a problem that we often encounter in application. Mainly because the voltage of the main circuit is too low (220V series is lower than 200V, 380V series is lower than 400V), the main reason: a certain way of the rectifier bridge is damaged or there is abnormal operation in the three ways of the thyristor, which may lead to the appearance of undervoltage problems, ...

Inverter power modification method - Reynolds Inverter power modification method - Reynolds

1. Yaskawa inverter G5-G7 power correction: enter the menu and then return to 02-04 after A01=4 is the power data, and the factory voltage of rehabilitation has also changed after the change. 2. Sanken inverter IHF-IPF-SHF series: enter the CD900 parameter and enter 365 to confirm (change 2 times...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system

From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.

The Reynolds SVG series was successfully completed The Reynolds SVG series was successfully completed

More than 40 sets of RNSVG series low-voltage power generator sets and RNZB series high-voltage reactive power automatic compensation devices designed and produced by Reynolds have been successfully completed and will be delivered in the near future. This product is owned by Shanghai Reynolds ...

The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy

Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military, mining, chemical industry, ...

Introduction and features of Reynolds soft starters Introduction and features of Reynolds soft starters

Reynolds soft starters include soft starters for high, medium and low voltage motors, including JJR1000 series, JJR2000 series, JJR5000 series, and RNB3000 series frequency converters. Reducing the starting power supply avoids voltage drops and voltage dips in the power supply. Smooth start-up avoids product damage. ...

Reynolds soft starter troubleshooting methods Reynolds soft starter troubleshooting methods

Common troubleshooting methods for Reynolds soft starters.   During the debugging process of the soft starter, the fault light is on, the motor is unresponsive, and the cause of the fault is analyzed: When the starting mode adopts the live mode, the operation sequence is wrong (the correct operation sequence must first deliver the main power supply, and then the control ...

Reynolds inverter manual Reynolds inverter manual

Reynolds inverter brochure (partial)   Before installing When unpacking, it is found that the machine has water or left water traces, indicating that the inverter has been flooded, so please do not install and use it. When unpacking, it is found that the machine is damaged and deformed or the parts are missing, please do not install and use it, otherwise there will be fault expansion and personnel ...

Reynolds soft starter manual Reynolds soft starter manual

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, and is a new type of starting equipment at the international advanced level. This product can effectively limit the starting current of asynchronous motor start-up, and is widely used in ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

The distance between the Reynolds frequency converter and the motor determines the cable and wiring method The distance between the Reynolds frequency converter and the motor determines the cable and wiring method

1. The interval between the inverter and the motor should be as short as possible. This reduces the cable's capacitance to ground and reduces the source of disturbance. 2. The control cable is shielded cable, the power cable is shielded cable or from the inverter to the motor.

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Reynolds inverter frequency Reynolds inverter frequency

That is, the upper and lower amplitudes of the output frequency of the inverter. Frequency is a maintenance function to avoid misoperation or failure of the external frequency setting signal source, which causes the output frequency to be too high or too low, so as to prevent damage to the equipment. You can set it according to the actual situation in the app. This function can also be used as a speed limit, so that ...

Faulty inverter – Reynolds inverter Faulty inverter – Reynolds inverter

In ancient times, there were ten major tortures, which made people unable to survive and die, and experienced the purgatory of the world; Today, there are ten "tortures" of inverters, and the same can make your inverters suffer. Let's follow the editor to find out which of the top ten "tortures" will make your inverter "worse than dead"! ...

The item that needs to be maintained after the inverter is shut down – Reynolds The item that needs to be maintained after the inverter is shut down – Reynolds

1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment. 2. Check the ventilation and lighting of the frequency conversion room, and the ventilation equipment can operate normally. 3. Check the inverter ...

Fault signal of the frequency converter - Reynolds frequency converter Fault signal of the frequency converter - Reynolds frequency converter

There are three types of fault signals for the inverter: (1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...

The inverter prepares the braking resistance factor – Reynolds The inverter prepares the braking resistance factor – Reynolds

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the capacitor voltage being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and avoid energy waste. However, the capacitance of the capacitor is ...

The inverter needs to rectify and then invert the cause - Reynolds The inverter needs to rectify and then invert the cause - Reynolds

Special inverter suppliers remind you that in daily industrial production, there are inverters that do not require rectifier units, which are the so-called alternating current inverters. However, the vast majority of the market is AC-DC-AC frequency converter, which also contains a rectifier unit, which is a certain level of technology and market competition.

How to measure a frequency converter with a multimeter – Reynolds How to measure a frequency converter with a multimeter – Reynolds

How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

Next Page »
12345678910Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top