Reynolds inverter frequency

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

That is, the upper and lower amplitudes of the output frequency of the inverter. Frequency is a maintenance function to avoid misoperation or failure of the external frequency setting signal source, which causes the output frequency to be too high or too low, so as to prevent damage to the equipment. You can set it according to the actual situation in the app. This function can also be used as a speed limit, such as a belt conveyor, because the material is not too much, in order to reduce the wear of machinery and belt, the frequency converter can be used, and the upper frequency of the frequency converter is set to a certain frequency value, so that the belt conveyor can run at a fixed, lower working speed.

                               Reynolds inverter frequency

1. Panel speed regulation: The frequency can be adjusted through the buttons of the panel.

2. Sensor control: The frequency can be controlled by the voltage or current change of the sensor as a signal input.

3. Communication input: control its frequency with PLC and other host computers.

More on that
Fault analysis of short circuit of inverter motor – Reynolds Fault analysis of short circuit of inverter motor – Reynolds

According to the different degrees of short circuit, the inverter can display the short circuit of the SCF1 motor; SCF2 has an impedance short circuit; SCF3 is short-circuited to ground. Causes of the problem: insulation problems with the cable from the motor or inverter to the motor; current transformer fault; ...

How to control the torque of the inverter vector according to the system - Reynolds How to control the torque of the inverter vector according to the system - Reynolds

A brief introduction to the progress of the inverter in terms of torque: This function adds the output voltage of the inverter so that the output torque of the motor is proportional to the square of the voltage, so as to improve the output torque of the motor. Improve the skill of insufficient torque at low speed output of the motor, and use the "vector manipulation" ...

What inverter to choose what occasion - Reynolds What inverter to choose what occasion - Reynolds

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter. When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...

Advantages of frequency converters over soft start – Reynolds Advantages of frequency converters over soft start – Reynolds

(1) The starting torque is large and the power factor is high. Because the power factor of the motor is related to the working frequency, the power factor under the power frequency power supply is much lower than that under the low-frequency power supply when the motor is running at low speed. The inverter can control the motor from low frequencies and ...

The water pump is controlled by a frequency converter – Reynolds The water pump is controlled by a frequency converter – Reynolds

1. The constant pressure water supply of the inverter increases the comfort of water supply by 3 times 2. Constant water pressure, reducing pipe bursts and leakage by 80% 3. High efficiency and energy saving, power saving effect up to 20%-60% (depending on the actual situation) 4. The use of frequency converters can realize multi-point pressure in different time periods.

Inverter breakdown factor – Reynolds Inverter breakdown factor – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus. Overvoltage alarm generally appears when the machine is shut down, and its main ...

Tips for using reducers - Reynolds Tips for using reducers - Reynolds

1. After 200-300 hours of operation, the first oil change should be carried out, and the quality of the oil should be checked regularly in the subsequent use, and the oil mixed with impurities or deteriorated oil must be replaced in time. Under normal circumstances, the reducer for long-term continuous operation should be replaced after 5000 hours of operation or once a year.

The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter

In order to measure stable harmonics, it is necessary to meet the following two conditions: At the top of the list, the signal is a stable periodic signal. Second, it is necessary to perform harmonic analysis according to the integer multiple of the period of the stable periodic signal. ...

Inverter starts the overload adjustment parameter - Reynolds Inverter starts the overload adjustment parameter - Reynolds

Motor overload: There is no need to set overload maintenance parameters in frequency conversion. The inverter generally acquiesces to the motor overload maintenance based on the motor power. Generally, it is 1.2 times and 60 seconds will report an overload failure. The overload factor is not the same for different frequency converters. ...

The lightning protection method of Reynolds inverter The lightning protection method of Reynolds inverter

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with lightning ...

Reynolds inverter parameter problem Reynolds inverter parameter problem

1. What are the factory recovery parameters of Reynolds inverter? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react? Decide...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

The factor that causes the breakdown of the inverter – Reynolds The factor that causes the breakdown of the inverter – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage formed due to various reasons exceeds the additional voltage, which is concentrated in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

The reason why the inverter burns the power supply inlet end - Reynolds The reason why the inverter burns the power supply inlet end - Reynolds

1. It is necessary to consider the touch and current size of the incoming terminal, if the terminal standard is small, perhaps the conductive function of the terminal is poor, which will directly cause the current carrying capacity of the terminal to be small and heated. 2. The inlet at the end of the inlet line must be pressed well and the like, if it is not pressed, it may cause ...

Reynolds drives RNB1000 series fault code resolution Reynolds drives RNB1000 series fault code resolution

Reynolds inverter fault codes: E.bC Reynolds inverter fault phenomenon/type: Brake unit failure   ​   Reynolds inverter failure may be caused: 1. Brake line failure or brake ...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Safety standards for AC drives – Reynolds Safety standards for AC drives – Reynolds

International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc. ...

The main failure mode of mechanical parts – Reynolds The main failure mode of mechanical parts – Reynolds

The top failure modes of mechanical parts: Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions. Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion General ...

The relationship between Reynolds motion control and frequency converters The relationship between Reynolds motion control and frequency converters

Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...

The difference between overload and overheating of the inverter – Reynolds The difference between overload and overheating of the inverter – Reynolds

The inverter is an electric control equipment that uses frequency conversion technology and microelectronic technology to control and communicate the motor by changing the power supply frequency of the motor operation. The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to communication), braking unit, drive unit, detection unit ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top