Megmeet Information SHOW
Megmeet inverters – what are the development directions of inverter-related technologies? Megmeet inverters – what are the development directions of inverter-related technologies?

1. Intelligent network The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the inverter complex in the factory.

Megmeet inverter - a common measure for anti-interference of high-voltage inverters Megmeet inverter - a common measure for anti-interference of high-voltage inverters

(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference. (2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...

Megmeet inverter - the fault handling method of low-voltage inverter Megmeet inverter - the fault handling method of low-voltage inverter

Before using the inverter, the inverter parameters should be carried out from the following aspects: First, confirm the motor parameters, the inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, and these parameters can be directly obtained from the motor nameplate. Clause...

Megmeet drives – a common fault in low-voltage drives Megmeet drives – a common fault in low-voltage drives

External electromagnetic interference can easily cause malfunctions If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...

Megmeet inverter – the energy-saving principle of low-voltage inverter Megmeet inverter – the energy-saving principle of low-voltage inverter

Inverter energy saving The energy saving of the inverter is mainly manifested in the application of fans and pumps. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus. When the motor cannot operate at full load, in addition to meeting the power drive requirements, ...

Megmeet inverter - introduction to the control method of low-voltage inverter Megmeet inverter - introduction to the control method of low-voltage inverter

1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of the industry. However, this control ...

Megmeet inverter - high-voltage inverter selection considerations Megmeet inverter - high-voltage inverter selection considerations

First, the disadvantages Choosing too high a voltage level results in too high an investment and a long payback period. With the increase of the voltage level, the insulation of the motor must be improved, so that the price of the motor increases. The increase of voltage level increases the number of series connections of power semiconductor devices in the inverter, and the cost rises. ...

Megmeet inverter - maintenance precautions for high-voltage inverter Megmeet inverter - maintenance precautions for high-voltage inverter

1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C 3. Summer temperature ...

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

1. Control through this abnormal failure The abnormal fault of the control channel is usually caused by the optical fiber communication between the sub-PWM board and the power unit board, which is generally caused by the following situations: 1. Poor contact of the optical fiber connection part or falling off of the optical fiber head; 2. Optical fiber signal transmitter/receiver ...

Megmeet inverter - the speed regulation method of high-voltage inverter Megmeet inverter - the speed regulation method of high-voltage inverter

1. Hydraulic coupling method. That is, a hydraulic coupling device is inserted between the motor and the load in series, and the size of the coupling force between the motor and the load is adjusted by the height of the liquid level, so as to realize the speed adjustment of the load; 2. Cascade speed regulation. Tandem speed regulation must use a wound asynchronous motor, and the rotor ...

Megmeet PLC - an introduction to the classification of PLC Megmeet PLC - an introduction to the classification of PLC

There are many types of PLC products, and their specifications and performance also vary. PLCs are usually classified according to their different structural forms, differences in functions, and the number of I/O points. 2.1 Classification by structural form According to the structural form of PLC, PLC can be divided into whole ...

Megmeet PLC – The importance of PLC industrial gateways Megmeet PLC – The importance of PLC industrial gateways

1. Realize remote control of industrial field equipment; 2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms; 3. Realize remote control of industrial site touch screen and remote mapping of configuration screens; 4. PLC industry ...

Megmeet MC100 series plc – the right hand man in refrigeration equipment Megmeet MC100 series plc – the right hand man in refrigeration equipment

First, the process requirements When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time. The high pressure collected is greater than that on the high pressure ...

Megmeet PLC maintenance inspection Megmeet PLC maintenance inspection

PLC maintenance and inspection steps: 1. Check and make sure the mains power is on (120 VAC) 2. Check the available 24V power supply 3. Identify problem areas. It is recommended that peak currents cover this error code, a control method consisting of multiple components distributed over an area or process.

Maintenance method of Megmeet PLC Maintenance method of Megmeet PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

Megmeet PLC - What are the steps to complete PLC commissioning? Megmeet PLC - What are the steps to complete PLC commissioning?

1. Check the circuit according to the drawing (without power transmission) The drawings of the general PLC system include two parts: the drawings in the cabinet and the drawings outside the cabinet; The drawing in the cabinet refers to the wiring diagram inside the cabinet; The out-of-cabinet drawings are the wiring diagrams of all electrical cabinets. This part needs to be checked for; ...

Hollysys' nationally produced SCADA system was the first to be put into application in the refined oil pipeline network of National Petroleum Pipeline Network Group Co., Ltd Hollysys' nationally produced SCADA system was the first to be put into application in the refined oil pipeline network of National Petroleum Pipeline Network Group Co., Ltd

Preface: Energy security is an overall and strategic issue related to the country's economic and social development, and is crucial to the country's prosperity and development, the improvement of people's lives, and the long-term peace and stability of society. For the first time, the 14th Five-Year Plan and the Outline of the Long-Range Objectives Through 2035 include "comprehensive energy production capacity" in the ...

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet inverter maintenance and testing method Megmeet inverter maintenance and testing method

Megmeet inverter maintenance and testing method   1. The Megmeet rectifier module is damaged It is usually caused by grid voltage or internal short circuit. In the case of sweeping internal short circuits, the rectifier bridge is replaced. When dealing with shortcomings on site, the user power grid should be checked. Such as electricity ...

Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use

Zhuzhou Lihui Technology Co., Ltd., a subsidiary of Megmit, has put into use a new production line of PEU intelligent production of new energy cars, leading the wave of intelligent production of PEU in the key "three electric" components of domestic new energy cars. Zhuzhou Lihui Technology Co., Ltd. production workshop, a new ...

Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition

From April 13 to 16, 2021, CHINAPLAS 2021 was grandly held at the Shenzhen World Convention and Exhibition Center (Bao'an New Hall) with the theme of "New Era· New Power, · Sustainable Innovation". As a vane of rubber and plastics professions and a barometer of shopping malls, the World Rubber and Plastics Exhibition has a 350,000 square meter ...

Next Page »
1234567Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top