Megmeet PLC – three connection methods for PLC and frequency converter Megmeet PLC – three connection methods for PLC and frequency converter

1. Use the analog output module of the PLC to control the inverterThe analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but requires the option to ...

Megmeet PLC - the basic composition of PLC Megmeet PLC - the basic composition of PLC

a. Power supply The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...

Megmeet PLC - What places should be avoided when installing PLC control? Megmeet PLC - What places should be avoided when installing PLC control?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

Megmeet PLC - What are the main components of PLC control cabinet? Megmeet PLC - What are the main components of PLC control cabinet?

1. Air switch Air switch is also called air circuit breaker, referred to as air open, is an indispensable component of the control cabinet, usually from the outside into the cabinet of power supply, must go through the air open, in order to reach the inside, the function of air open in addition to the power supply, more as short circuit protection and overload protection...

Megmeet PLC – the maintenance steps of the PLC control cabinet Megmeet PLC – the maintenance steps of the PLC control cabinet

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

Megmeet PLC - Introduction to the basic structure of PLC controller Megmeet PLC - Introduction to the basic structure of PLC controller

1. Power supply The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...

Megmeet PLC - What are the functions of the PLC gateway? Megmeet PLC - What are the functions of the PLC gateway?

1. PLC industrial gateway has rich interfaces and is easy to deploy It supports 4G, 3G, PPPOE, Wi-Fi network, digital IO input and output, and serial terminal communication, providing different access solutions for different applications. 2. Intelligent analysis and efficient access Inline protocol analysis ...

Common faults and solutions of Megmeet PLC Common faults and solutions of Megmeet PLC

1. Do not execute the program: The input check is identified by the input LED indicator or the input monitor composed of a writer. When the input LED is not lit, it can be preliminarily determined that the external input system is faulty, and then check with the multimeter. If the output voltage is not normal, it can be determined that ...

Megmeet servo drive - common faults and treatment methods of servo drives Megmeet servo drive - common faults and treatment methods of servo drives

1. The motor runs differently in both directions Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position. Solution: Detect or detect the correct phase; Reposition the potentiometer. 2. The motor speed is abnormal Cause of failure ...

Megmeet PLC – What are the advantages of PLC compared to relays? Megmeet PLC – What are the advantages of PLC compared to relays?

(1) In terms of control method: PLC adopts a program to achieve control, which is easy to change or increase the control requirements, and the contact points of PLC are unlimited; (2) In terms of working mode: PLC adopts serial working mode to improve the anti-interference ability of the system; (3) Control speed: PLC ...

Megmeet inverter – three ways to connect the PLC to the inverter Megmeet inverter – three ways to connect the PLC to the inverter

(1) Use the analog output module of PLC to control the analog output module of the inverter The analog output module of the PLC outputs 0-5V voltage signal or 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Megmeet inverter – the inverter's protection of itself, the motor and the system Megmeet inverter – the inverter's protection of itself, the motor and the system

1. The inverter protects itself Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the protection of the inverter itself, the limit value of overcurrent, overvoltage, undervoltage, etc., when the inverter is running, if it exceeds ...

Megmeet inverter - the daily maintenance and overhaul of the inverter Megmeet inverter - the daily maintenance and overhaul of the inverter

1. Regularly dust the inverter, focusing on the rectifier cabinet, inverter cabinet and control cabinet, if necessary, the rectifier module, inverter module and the circuit board in the control cabinet can be removed for dust removal. Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. The inverter is due to the ...

Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter? Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter?

The system efficiency is equal to the product of the efficiency of the inverter and the efficiency of the motor, and the system efficiency is higher only when both are working at higher efficiency. From the perspective of efficiency, the following points should be paid attention to when selecting the power of the inverter: 1) Inverter power value and motor power ...

Megmeet inverter - introduction to the classification of inverters Megmeet inverter - introduction to the classification of inverters

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

Megmeet inverter - what are the control methods of the inverter? Megmeet inverter - what are the control methods of the inverter?

Sinusoidal Pulse Width Modulation (SPWM) control mode It is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of industry. However, this type of control is at low frequencies, ...

Megmeet drives – what are the components of a drive? Megmeet drives – what are the components of a drive?

The inverter is composed of a main circuit, a rectifier, a flat wave circuit, and an inverter. 1) Main circuit: The main circuit is the power conversion part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the DC ...

Megmeet inverter – the difference between voltage type inverter and current type inverter Megmeet inverter – the difference between voltage type inverter and current type inverter

1. The load of the buffer inverter without functional quantity is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Since the power electronic switching devices cannot be stored for energy, the non-functional energy can only rely on the energy storage elements (filters).

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet inverter - how to choose the inverter? Megmeet inverter - how to choose the inverter?

1. Understand the type of variable frequency load The correct selection of the frequency converter is very critical for the proper operation of the control system. When selecting a frequency converter, it is important to fully understand the load characteristics driven by the frequency converter. In practice, production machinery is often divided into three types: constant torque load, constant ...

The cause and treatment method of the fault code Eroc1 of Megmeet inverter The cause and treatment method of the fault code Eroc1 of Megmeet inverter

1. Overcurrent fault of inverter Fault Code: OCF. (1) Fault name: inverter overcurrent fault (2) The cause of the failure: the motor nameplate data input is incorrect: the load dragged by the motor is too heavy: the machinery is stuck; Motor stalled. (3) ...

Next Page »
1234567Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top