1. Use a vacuum cleaner with a plastic nozzle to completely clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment.
2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can work normally.
3. Check that the connection between the internal cables of the inverter should be correct and reliable.
4. Check that all the grounding in the inverter cabinet should be firm, and there is no rust at the grounding point.
5. The connecting nuts of the internal cable of the inverter should be tightened again every six months.
6. Check the tightness of all electrical connections, check that there are no abnormal discharge traces in each circuit, and there is no strange smell, discoloration, cracks, damage and other phenomena.
7. After each maintenance of the inverter, it is necessary to carefully check whether there are missing screws and wires, etc., to avoid short circuit incidents caused by small metal objects. In particular, after making major changes to the electrical circuit, the connection of the electrical connection line is correct and reliable, so as to avoid the occurrence of "reverse power transmission".
|
More on that
|
Delta's servo motor maintenance and safety measures
Delta's servo motor system is planned for industrial use, and it is necessary to have a sufficient understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and equipment, and to ensure that the motor can be used correctly, please read this safety precaution carefully before installing the machine.
...
|
|
Precautions for long-term idle inverter - Delta inverter
If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:
...
|
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud platforms are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Delta's inverter adjusts the motor speed mode
The speed control on Delta's inverter is mainly as follows:
1. Adjust the variable resistance directly from the surface of the Delta inverter
2. External analogue voltage or current signal to adjust
3. Take advantage of the multi-function of the inverter ...
|
|
The impact of Delta's inrush current on the inverter
In the process of repairing the inverter, it is found that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-induced rotor, the current impact must have a negative impact on the motor, the inverter (Variable-frequency Drive, ...
|
|
Introduction to the features of Delta's power modules
1) Brief planning. Only one battery module, paired with several discrete components, is able to obtain a battery.
2) Shorten the development cycle. It is generally equipped with a variety of input, output, and battery module options. Users are also able to repeat or cross-stack, combined with modular batteries, to complete multi-channel ...
|
|
Problems in the use of Delta inverters and Delta motors
Delta's motors are the most frequently used rotating things so far, and with the development and spread of Delta inverters, they need to be used in conjunction with inverters.
However, in the process of combining inverters and motors, it is inevitable to encounter a lot of ...
|
|
Requires an inverter speed control application – Delta
Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
Introduction to the common sense of Delta inverter
The low-voltage fuse cannot be used as an overload maintenance for the motor.
It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line.
The additional current of the fuse must be greater than or equal to the additional current of the melt.
...
|
|
Delta launched an integrated control solution for layer winding
As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.
|
|
Problems with Delta's compact pressure transmitters
1. The transmitter does not return to zero under no pressure?
Answer: The cleaning method is to remove the transmitter from the device position, investigate whether the zero position is normal, and replace the pipeline sealing ring if it is normal. Check together whether the transmitter is perpendicular to the piping assembly, and if not, adjust the transmitter zero.
...
|
|
Delta UPS power supply RT5K extension configuration method for 2 hours
Engined DC: 1K=36V, 2K=72V, 3K=96V, 5K, 6K, 10K=192V
UPS power supply accounting formula: 1KVA (volt-ampere) =700W (watt) =1000VA (volt)
UPS power supply x extended time + starting DC = how big the battery is
Start DC + V number of battery = how much power is distributed ...
|
|
Analysis of communication problems of Delta inverters
Problem Clarification:
Communication Transmission Timeout: The Modbus transmission between the VFD and the Keypad times out
Solution:
VFD does not respond to Keypad's communication commands.
1. Confirm the communication quality of the communication wiring and contacts.
2. Please use the RESET key to clear the Fault ...
|
|
Delta's touch screen controls the inverter method
1. The touch screen is controlled by PLC inverter
1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.
|
|
Servo motor speed improvement method - Delta
When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor.
...
|
|
The inverter sets the characteristic parameters of the motor
1. Parameters to be set for the motor
When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...
|
|
Delta's Ultron HPH provides power protection that meets the needs of green data centers
Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...
|
|
How to use Delta's inverter operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
The inverter needs to be equipped with a braking resistor-Delta
The inverter is equipped with a braking resistor, mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the voltage of the capacitor being too high. Theoretically, if the capacitor stores a lot of energy, it can be used to release it to drive the motor to avoid energy waste, but the capacity of the capacitor is limited.
|
|
Introduction of incoming reactor for inverter - Delta
Reactors are also called inductors, and when a conductor is energized, a magnetic field will be generated in a certain space scale occupied by it, so all electrical conductors that can carry current have inductance in a general sense. However, the inductance of the energized long straight conductor is small, and the magnetic field generated is not strong, so the actual reactor is conductive.
|
|