Voltage regulator power selection and determination - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

1. The output power of the voltage regulator is the maximum power

Basically, most of the nominal power of household appliances refers to active power, and most of the so-called refrigerators, air conditioners and those water pumps used in the home are also inductive loads that generate instantaneous currents, so basically refrigerators, air conditioners, and water pumps are × (3-5 times) according to power.

                               Voltage regulator power selection and determination - Delixi

2. In most cases, the power algorithm is used by professional hydropower installation technicians and factory professional electricians, engineers and voltage regulators

In many hours, its industrial equipment is also in accordance with the rated power at least multiplied by more than 2 times the operating power, and many times, if it is used in the use of its motor operation equipment or the use of high-current power generation device and impact load equipment, many hours, it is advisable to choose more than 3 times the capacity of the voltage regulator, this is done in order to start the current as soon as possible, the power supply line voltage reduction and can not operate normally.

3. If it is a 0.5KVA-3KVA voltage regulator equipment, when selecting its output voltage of 110V, then it is recommended that the input capacity should not exceed 40% of the rated capacity, and if it is at the output end, then the output capacity of 110V and 220V should be 50% of the rated capacity when used at the same time to avoid overload.

At the same time, we are reminded that when we choose, we advocate that it is best to select the stabilized power supply according to the rated power of the electrical equipment, the inrush current at start-up, the inductance, the capacitance and other load conditions, so that it is the most reliable!

More on that
How to change the original parameters of the inverter and re-set - Delixi How to change the original parameters of the inverter and re-set - Delixi

The inverter has many set parameters, each of which has a certain selection range. In the process of use, it is often encountered that the inverter cannot operate normally due to improper parameter settings. Therefore, the relevant parameters must be corrected. ...

What are the advantages of Delixi inverter What are the advantages of Delixi inverter

(1) Optimize electrical equipment: when the motor is started, there is no large current impact, and the load of the transformer is reduced. (2) The energy-saving effect is obvious: it can reach 20%-45%. (3) Extend the life of the whole machine: it has the function of soft start, reducing the load ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.

Delixi voltage regulator in the case of no load stable work? Delixi voltage regulator in the case of no load stable work?

Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...

Delixi Electric CDW3 universal circuit breaker introduction Delixi Electric CDW3 universal circuit breaker introduction

The CDW3 series frame circuit breakers are rated from 400A to 6300A and 415V/690V AC for extreme environmental conditions of 50 Hz AC and -40°C to 70°C. It is mainly used in the distribution network, distributing electric energy, protecting lines and power supply equipment from ...

Introduction of low dropout linear regulator - Delixi Introduction of low dropout linear regulator - Delixi

LDO, or low dropout regulator, is a low-dropout linear regulator that uses a transistor or field-effect transistor (FET) operating in its saturation region to subtract the excess voltage from the input voltage used to generate a conditioned output voltage. ...

Delixi inverter E180 series technical features Delixi inverter E180 series technical features

1. Superior performance The new vector control algorithm is adopted, and the starting cabinet is large, the torque response is fast, and the control accuracy is high, which further improves the operation efficiency of the motor. 2. Powerful function and low cost of use Built-in large number of ...

Delixi time control switch adjustment Delixi time control switch adjustment

Press the revoke function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time when the demand is closed and open to the specified value, if the demand is set to multiple groups, then press the punctual function key to set, without multiple groups ...

Delixi voltage regulator safety precautions Delixi voltage regulator safety precautions

1. When the stabilized power supply is powered on, please do not disassemble the stabilized power supply or pull the input and output cables of the stabilized power supply at will to prevent electric shock or other electrical safety accidents. 2. The input and output connections of the regulated power supply must be reasonably arranged, ...

The difference between inverter reactor and filter - Delixi The difference between inverter reactor and filter - Delixi

The following options are available on the output side of the drive: 1) Output reactor, when the length of the cable output from the inverter to the motor is greater than the specified value of the product, the output reactor should be added to compensate for the charging and discharging influence of the coupling capacitor when the long cable of the motor is running, so as to prevent the inverter from overcurrent. Output ...

The reason for the instability of the voltage regulator output - Delixi The reason for the instability of the voltage regulator output - Delixi

It shows that the voltage regulator base is not voltage corrected, and the voltage regulator in this situation is like a transformer, the higher the input voltage, the higher the output voltage, the input decreases and the output voltage also decreases. This...

Delixi E180 universal inverter introduction Delixi E180 universal inverter introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...

Delixi product parameter unit VF and V difference Delixi product parameter unit VF and V difference

Voltage vf and v difference: The two have different meanings, vf on the battery represents the feedback voltage, while v represents the capacity of the battery, which is the unit of measurement of voltage. Lithium battery is a kind of battery with lithium metal or lithium alloy as the positive/negative electrode data and the use of non-aqueous electrolyte solution. ...

Installation steps of motor protector - Delixi Installation steps of motor protector - Delixi

1. According to the requirements of the device part and the needs of the maintenance function, reasonably select the motor maintainer model and its various maintenance action parameter settings; 2. According to the requirements of the product operation manual, the correct device should be connected correctly according to the use of each terminal, and the operating power supply should be connected to the control ...

Delixi inverter installation and wiring Delixi inverter installation and wiring

1. The device of the inverter 1.1 The device environment requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...

The core difference between air disconnector and circuit breaker - Delixi The core difference between air disconnector and circuit breaker - Delixi

1. Although the air switch is a type of circuit breaker, it is a switch that will automatically disconnect as long as the current in the circuit exceeds the rated current. However, air switches are used in low-voltage distribution networks and electric traction systems, mostly on the low-voltage side. Widely used in the home, such as general household switches ...

The impact of inverter cable design on the life of the motor and cable - Delixi The impact of inverter cable design on the life of the motor and cable - Delixi

Reflected waves caused by a cable-motor impedance mismatch are prevalent in all AC VFD uses. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable. ...

Delixi fan and pump load frequency conversion selection Delixi fan and pump load frequency conversion selection

Delixi general fan, pump, the requirements for the inverter are simple, only the inverter capacity is equal to the motor capacity. Roots blowers, deep-water pumps, sediment pumps, and fast-changing musical fountains are available in a larger capacity. Lifting...

Delixi voltage regulator problem repair Delixi voltage regulator problem repair

1. The output voltmeter is constantly swinging back and forth, and sparks are generated at the carbon brush 1. The contact pressure between the carbon brush and the coil plane is too small 2. The carbon brush is severely worn 1. Clean the coil and carbon brush with a fine file or sandpaper, and then adjust the carbon brush pressure 2. Replace the carbon brushes with new ones ...

Delixi time control switch adjustment Delixi time control switch adjustment

First, press the "Cancel Recovery Button" 4 times in a row; Then adjust the clock (the factory has been adjusted), if you need to adjust it again, press and hold the "clock key" together, and then press the "school week, time key, school minute key" to adjust the Beijing time. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383