Delixi CDI-EM60 series inverter is a high-performance inverter, with the following characteristics and use:
Characteristic:
1. It has good stability and reliability to ensure the stability and safety of the system operation.
2. High degree of speed, wide range of speed control, can be widely used in a variety of mechanical and electrical equipment.
3. It has the best rate and energy-saving performance, which can greatly reduce energy consumption.
4. Simple maintenance, easy to install, debug and repair.
Use:
1. Industrial machinery: It can be used for speed control and process control of various machinery and equipment, such as fans, pumps, compressors, cutting machines, etc.
2. Automatic control: It can be used in automatic control systems such as assembly line production, packaging machines, and transportation machines.
3. Elevator control: motor speed regulation of the elevator in the building.
4. Commercial transformers, water pumps, fans, mechanical compressors, dispensing machines, sterilization, liquid distribution and mobile machinery, etc.
|
More on that
|
Delixi inverter common problems
1. The pressure of Delixi inverter system is unstable and simple vibration?
Answer: The pressure of the system is unstable, which may be due to the following reasons:
A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...
|
|
The main functions of Delixi regulated power supply
The primary effect of Delixi voltage regulator is, of course, to stabilize the voltage. When the grid voltage fluctuates instantaneously, the regulated power supply will compensate for the voltage amplitude with a response speed of 10-30ms
1. Stable voltage:
Wangwen Shengyi, Delixi stabilizes ...
|
|
Delixi relay maintenance method
Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.
|
|
Causes and solutions for circuit breaker closing failure - Delixi circuit breaker
1. Failure analysis.
1) Closing fuse, control fuse blowing or poor contact.
2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker.
3) The DC voltage is too low.
4) Closing and locking action.
...
|
|
Delixi voltage regulator fault performance and elimination
Regulator problem 1: The regulator cannot be started
Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken.
Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch.
Voltage Regulator ...
|
|
Delixi rangefinder analysis
Delixi Group focuses on low-voltage power distribution and industrial automation in the field of comprehensive solutions suppliers, founded in 1984, is a collection of industrial operations, brand operations, capital operations as one of the large enterprise groups, for 18 consecutive years ranked among the top 500 Chinese enterprises. Delixi rangefinder is designed for ...
|
|
The core difference between air disconnector and circuit breaker - Delixi
1. Although the air switch is a type of circuit breaker, it is a switch that will automatically disconnect as long as the current in the circuit exceeds the rated current. However, air switches are used in low-voltage distribution networks and electric traction systems, mostly on the low-voltage side. Widely used in the home, such as general household switches ...
|
|
The operating structure of the high-voltage circuit breaker - Delixi
1. Classification of switch operation organization
At present, the switches we encounter are generally divided into many types, such as oil-rich type (old model, now you can't see it at all), oil-poor type (some user stations also have it), SF6, vacuum, GIS (combined electrical appliances) and so on. These are all about the arc extinguishing medium of the switch. ...
|
|
Delixi DZ47sGQF self-resettable over/undervoltage protector
In order to meet the needs of business development, Delixi Electric newly upgraded to create DZ47sGQF Navigator series of self-resettable over- and under-voltage protectors, the new products have a leading technology platform, better performance and quality, can completely replace the old product DZ47GQF.
...
|
|
Changes in the control mode of the inverter - Delixi inverter
In the process of practical speed regulation, an ordinary AC power supply with adjustable frequency can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the effective use of the motor magnetic field, the pressing starting current and the desired torque characteristics, such as low-frequency torque characteristics.
|
|
The cause of the failure of Delixi inverter
1. Overcurrent (short circuit)
Overcurrent problems are the most common in the side of various faults in the inverter. The problem is mostly due to the following problems: first, as long as the speed converter is reported when starting, it is clear that the overcurrent is very serious, and most of them are load short circuits, mechanical parts stuck, inverters...
|
|
Transformer abnormal power-off treatment fault method - Delixi
First of all, when the transformer is faulty, we must cut off the power supply of the transformer through abnormal methods for the first time, and many major electrical fires and electric shocks are caused by the main gate is not closed. Now let's take a look at what to do.
...
|
|
General parameter setting skills of inverter - Delixi
The setting menu of the inverter is divided into a first-level menu, a second-level menu, etc., and the menu is followed by parameters.
If the inverter starts in standby (ready to run) condition, set the FUn-PSS-SP2 parameter to 15Hz, and then return to the standby state operation.
In the practice setting ...
|
|
The difference between circuit breaker and disconnector - Delixi
The disconnector is a kind of switching equipment that is mainly used for "blocking the power supply, reversing the operation, and connecting and blocking the small current circuit", without arc extinguishing function. When the barrier switch is divided into directions, there is an insulation distance between the contacts that meets the specified requirements and a significant disconnection mark; When in the azimuth, it can carry ...
|
|
Damage and repair of internal electronic components of the inverter - Delixi
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter).
Middle...
|
|
Delixi parameter voltage regulator performance and advantages
1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...
|
|
What are the advantages and disadvantages of dry and oil regulators? - Delixi
Oil Regulator: Also known as non-contact inductive regulator or intelligent non-contact regulator (only the name of the company's own selling point).
Forte:
1. No contact, no protection, impact resistance (especially instantaneous impact, 2 times of normal.) The reason for this is the slow response, which ...
|
|
Problems affecting the normal operation of the inverter - Delixi
Seriously affect the normal operation of the inverter. The core components of the inverter are IGBT power semiconductor switching components. When they are working properly, they generate a lot of heat. If there is no fan forced cooling, the sensing head will immediately detect (IGBT) overheating (IGBT) and send it ...
|
|
Reducer troubleshooting method - Delixi
01 "O" ring spell
In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings.
O-rings are a very common type of product sealing planning.
|
|
Daily maintenance of reducer - Delixi
The reducer is a kind of transmission equipment used for low speed and high torque, which uses the speed converter of the gear to reduce the number of revolutions of the motor (motor) to the required number of revolutions, and obtains a large torque organization. Its main function is to reduce the speed and improve the output torque at the same time, and the torque output share is according to the motor ...
|
|