T-cam switches and P-block switches are used in a wide range of standard circuits and currents, and the number of combinations of cam switches is virtually unlimited. Different designs, front panels and dedicated switches ensure optimum sensitivity to meet the requirements.
Q1: What is the difference between P switch and T switch?
A: P switch is a load blocking switch, mainly for the main circuit load breaking and blocking application, as long as 3P and 3+N, can add auxiliary contacts; T switch is a multi-function switch, the contact sequence is diverse, modular contact unit, can be any combination of customized products, such as: on-off switch, transfer switch, reversing switch, star triangle switch, stepper switch, multi-speed switch and surface control switch and so on.
Q2: Can the cam switch T be used as a load barrier switch?
A: Yes. The T switch is used as a load barrier switch, and its function is exactly the same as that of the P switch.
Q3: Can the T-switch be equipped with an auxiliary contact module?
A: T switch products can not be equipped with auxiliary contact modules, T switch to choose the function of auxiliary contact, in the selection, together with the main contact to consider the contact sequence.
Q4: What is the function of T0-3-15683/EA/SVB and what is the contact?
A: This type of switch is the main switch of the line, which can directly interrupt the corresponding motor and other loads. The number of contact modules is 3 layers, and the total number of contacts is 6 pairs, including 3 pairs of main contacts, 2 pairs of normally open and 1 pair of normally closed auxiliary contacts.
Q5: What type of T/P switch can complete the padlock function?
A: Whether it is a P switch or a T switch, only as the main switch with ON/OFF function can complete the padlock function. That is to say, if the type contains SVB or SVB-SW depiction, it can complete the padlock function.
Q6: What is the difference and type characteristics between the general main switch and the main switch with emergency stop function?
A: Generally, the main switch is used for power control and blocking in a part or subsystem and single load in a certain distribution area, and the general handle is designed in black and gray color, which is depicted by SVB-SW in the type; The main switch with emergency stop function is higher than the general main switch, generally in a regional, independent system, only one of this switch, and the standard color of the handle is designed to be red and yellow, that is, the type contains the word SVB. The red and yellow color is the positive warning sign, which means that in the state of urgency, it is easy to identify and quickly cut off the power supply.
Q7: Can the handle of the transfer switch T0-1-8210/E be locked?
A: No, you can't. The transfer switch is not an ON/OFF main switch and cannot be equipped with an SVB or SVB-SW handle, so it cannot be padlocked.
Q8: Can the T/P switch be supplied with ATEX explosion-proof type now?
A: Not available right now. When customers need to integrate the switch with other components, they should consider the explosion-proof problem in a unified manner.
Q9: What is the maximum number of contact modules that can be achieved by the T switch? What is the total number of contacts?
A: The T-switch can be retrofitted with up to 11 layers of contact modules, bringing the total number of contacts up to 22 pairs.
Q10: Can I add 2 pieces to the P11-P1/P3E switch assist for the P1 and P3 leveling device method?
A: It can add 2 pieces, and can add one piece on the left and right, and can reach 2 normally open and 2 normally closed.
Q11: What is the maximum number of connecting rods for the switches of the P1 and P3 rear device methods?
A: Up to 4 sections can be added, each section is 25mm.
Q12: Does the P switch with SVB come with PE grounding and N-wire terminals?
A: P switch types with SVB are equipped with PE ground and N terminal as standard.
Q13: Can the N-pole attachment and auxiliary contacts of the P1 and P3 switches be installed together?
A: It is possible to install 1 standard auxiliary and 1 N-pole module together.
Q14: Can the ON/OFF switch with a small black handle be replaced with a large padlock handle?
A: Yes. If a customer has previously ordered an ON/OFF switch without the SVB or SVB-SW lettering, they can also purchase a unique SVB or SVB-SW handle to complete the padlock function.
Q15: What is the maximum switching current of the exterior device?
A: The exterior device is a complete set of device boxes with IP65 protection level. Its P switch can achieve the maximum P3-100, and some T switches can achieve T8 (275A). In order to complete the exterior device, the customer must select the appropriate cabinet for the above current standards.
Q16: What is the difference between TM switch and T switch?
A: Both are cam switches. TM is more miniaturized and can be used to control a smaller capacity load circuit, which is small in size and saves more installation space. In addition to the traditional thumb handle operation, the TM series is also capable of key head operation.
Q17: Is there a sign sign for the standard type of T/P switch in Chinese?
A: No. As long as: German, English, French, Italian, Portuguese, Spanish and Sweden, etc., other languages need to be customized, or choose blank logo products, by the customer DIY.
Q18: Does Eaton have a P switch for the switchboard installation method?
A: Yes. Eaton has the P1 and P3 series of distribution cabinet units with extension rods up to 100A. Among them, the metal extension rod is available in suitable lengths of 400mm and 600mm cabinet depth. The operating handle is available in SVB series and K series, which are sensitive and optional.
Q19: How to know the IP65 protection level of T/P?
A: The IP65 rating promised by Eaton refers to the level of protection that can be reached by the front of the switch after the standard device, and not in all directions. As for the exterior device, when the customer opens the wiring of the knock-out hole of the box, the corresponding protection level of the glander must be installed to reach the standard.
Q20: What is the scope of product certification for T/P switches?
A: There is no 5-well standard, there is a 6-well standard.
Q21: Can the M22-A4 be compatible with the M22 pushbutton and indicator light from a single head?
A: As a global production line, T/P switches have all the world's mainstream certifications. Such as: CE, VDE, UL, CSA, CCC and all kinds of ship inspection certifications.
|
More on that
|
Tianyi switch - how to use the dual power transfer switch correctly
1. When the power is cut off for some reason and the power supply cannot be restored in a short period of time, the backup power supply must be enabled:
(1) Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet of the power distribution room, and the mains power cut-off of the dual-power switching box), and pull the double-cast anti-backing switch to the side of the self-provided power supply, ...
|
|
Tianyi switch - the difference between high-voltage load switch and high-voltage isolation switch
1. The high-voltage load switch can be broken with load and has the function of self-extinguishing arc, but its breaking capacity is very small and limited.
2. The high-voltage isolation switch is generally not able to break with load, there is no arc extinguishing cover in the structure, and there is also an isolation switch that can break the load.
|
|
Tianyi switch - the difference between switching power supply and linear power supply
(1) The cost of linear power supply is higher than that of switching power supply at a certain output power point.
Therefore, with the development and innovation of power electronics technology, the switching power supply technology continues to break through and innovate.
|
|
Tianyi switch - the performance and main features of dual power automatic transfer switch
performance
1. Adopt double-row composite contacts, cross-connected mechanisms, micro-motor pre-energy storage and micro-electronic control technology, basically achieve zero arcing (no arc extinguishing cover);
2. Adopt reliable mechanical interlocking and electrical interlocking technology;
3. Adopt zero-crossing technology;
4、 ...
|
|
Tianyi switch - the characteristics and classification of load isolation switch
First, the characteristics of the load switch
A load switch is a switchgear between a circuit breaker and an isolation switch. It has a simple arc extinguishing device, which can cut off the rated load current and a certain overload current, but cannot cut off the short-circuit current
Second, the classification of load switches
According to the operating voltage ...
|
|
Tianyi switch - the method of adjusting the current of Tianyi switch
1. Change the reference current of the feedback module
Regulating the reference current is the most basic way to regulate the output current of a switching power supply, and it can usually be achieved by rotating a potentiometer or toggling a switch. Changing the reference current allows the magnitude of the feedback current to be compared with it, so as to control the switch ...
|
|
Tianyi switch - the selection principle of air switch
1. Determine the type and protection form of the circuit breaker according to the requirements of the line for protection - determine the selection of frame type, device type or current limiting type.
2. The rated voltage UN of the circuit breaker should be equal to or greater than the rated voltage of the protected line.
3. The rated voltage of the circuit breaker undervoltage tripper ...
|
|
Tianyi switch - the difference between the dual power supply automatic transfer switch CB and PC grade
First, the principle is different
1. Class Cb automatic switch is an electronic product that converts one or more load circuits from one power source to another
2. PC-level automatic transfer switchgear is an electrical appliance that converts one or several load circuits from one power supply to another. ...
|
|
Tianyi switch - dual power supply automatic transfer switch operating procedures
1) When there is a power outage for any reason and the power cannot be restored in a short period of time, the backup power supply must be activated
1. Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet in the distribution room, and the mains power supply cut-off of the dual power switching box), and pull the double-cast anti-reverse switch to the side of the self-provided power supply to ensure that the power supply is protected.
|
|
Tianyi switch - PCB design considerations for switching power supplies
In the design of switching power supply, the physical design of the PCB board must be proper, otherwise it may cause excessive electromagnetic interference and lead to unstable power supply.
1. The design process from the schematic diagram to the PCB should be rigorous and perfect: the establishment of component parameters ...
|
|
Tianyi switch - dual power supply automatic transfer switch normal working conditions
1) Ambient air temperature: The upper limit of ambient air temperature is +40°C, the lower limit of ambient air temperature is -5°C, and the average value of ambient air temperature for 24h does not exceed +35°C
2) Altitude: The altitude of the installation site does not exceed 2000m.
3) Atmospheric conditions: Atmospheric relative humidity in the surrounding air ...
|
|
Tianyi switch - 9 tests and methods for switching power supply
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Tianyi switch - how to choose the right industrial switching power supply?
1. First of all, it is necessary to select the appropriate input voltage specification;
2. Choose the right power. In order to extend the service life of the power supply, it is necessary to select an additional type with 30% of the rated output power.
3. Consider the load characteristics. The load added is a motor, bulb or capacitive load, and the current at start-up ...
|
|
Tianyi switch - 5 methods to suppress ripple in switching power supply
1. Increase inductance and output capacitance filtering
According to the formula of the switching power supply, the current fluctuation in the inductor is inversely proportional to the inductance value, and the output ripple is inversely proportional to the output capacitance value. Therefore, increasing the inductance and output capacitance can reduce ripple.
In the same way, the output ripple is the same as the output ...
|
|
Where can Tianyi switch - limit switch be used?
daily life
There are many aspects of the use of limit switches, and it is found in many electrical appliances. So what effect can such a simple switch have? It is first and foremost a chain maintenance effect. The most common example is its use in washing machines and tape recorders (video recorders). ...
|
|
Tianyi switch - the main accessory of the air switch
Internal accessories
Auxiliary contact: The auxiliary contact is the contact mechanically linked by the main circuit of the circuit breaker, which is mainly used for the display of the circuit breaker opening and closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, to ...
|
|
What requirements should be met by Tianyi switch - disconnector?
(1) The disconnector should have an obvious disconnection point, which is easy to identify whether the electrical appliance is disconnected from the power grid.
(2) There should be reliable insulation between the disconnect points of the disconnector, that is, there should be enough distance between the disconnect points of the disconnector to ensure that it can work reliably under harsh climatic conditions, and ...
|
|
Tianyi switch - precautions for switching power supply to regulate current
1. Pay attention to stability
When adjusting the output current of the switching power supply, the stability of the circuit must be ensured, otherwise there will be current fluctuations, disturbances and other phenomena, which will affect the normal operation of electronic equipment. Therefore, it is necessary to perform a ...
|
|
The main features of VTeam X42 series limit switches
Uses: X42 series limit switches can be widely used in various types of mechanical equipment, automatic assembly lines and other light and medium load occasions, can detect the object action state, such as presence and absence, movement position, end of stroke, etc.
Overview: The switch is mainly composed of switch operating parts, ...
|
|
Tianyi switch - analysis of wiring questions and answers of button switches
1. How to wire the button switch with a light, there are a total of five binding posts on the button, and now you can only measure how to connect the power cord, but the light is on and I don't know how to connect.
Answer: This situation is relatively simple, this kind of switch should be two terminals connected to the lamp, the other 3 terminals are switches, find out ...
|
|