The inverter is composed of many electronic parts, such as semiconductor components, etc., and the problem of replacing a related component is involved in the operation and maintenance, because of the composition or physical characteristics of the inverter, it will deteriorate in a certain period of time, which will reduce the characteristics of the inverter, and even cause failure. Therefore, it is necessary to carry out regular replacement in order to prevent maintenance.
1. Replace the cooling fan
The main circuit of the inverter is cooled by the semiconductor equipment cooling fan to speed up the heat dissipation and ensure the normal operation below the promised Wendy. The life of the cooling fan is limited by the bearing, which is about 10000-35000h. When the drive is running continuously, the fan or bearing needs to be replaced once after a few years. The replacement period of the cooling fan is greatly affected by the ambient temperature, and it is necessary to replace the cooling fan immediately when abnormal sound and abnormal oscillation are found.
2. Replace the capacitor
Large-capacity electrolytic capacitors are used in the central DC circuit, and their performance deteriorates due to factors such as pulse current. The deterioration is greatly affected by the ambient temperature and operating conditions, under normal conditions, the service cycle is about 5 years, and the deterioration of the capacitor develops rapidly after a certain time, so check the length of the circumference is one year, and the number of life is within half a year.
3. Replace the timer
The timer will change greatly after several years of use, so replace it after checking the action time.
4. Replace the fuse
The additional current of the fuse is large and the load current is large, and the service life is about 10 years under normal operating conditions, and it is necessary to check the maintenance and even replacement at this time.
5. Replace relays/contactors
After the relay and contactor reach the required cumulative number of switches, a contact defect occurs, and it is necessary to check and replace it. Secondly, knowing the meta-equipment that may need to be replaced, here is a simple make-up of the basic requirements for replacing meta-equipment.
1) Find out the basic parameters and appearance of the equipment to be replaced. The basic parameters include the additional operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the full voltage. The shape requirements include the external scale, terminal position and device form, etc., and then replace the required equipment according to the same requirements.
2) All connectors should be recorded or marked when disassembled to avoid misplacement during replacement or rehabilitation.
3) The contact surface between the power equipment and the radiator should be evenly coated with thermal grease and fastened with screws.
* In most cases, the machine is in operation, and when the machine is not running, it is necessary to take proper care of the inverter.
* In most cases, the machine is in operation, and when the machine is not running, it is necessary to take proper care of the inverter.
1) Storage
The room should be dry, no direct sunlight, no corrosive gas, no dust; The relative humidity is 20%-90% and there is no frost; The temperature is between -10 and 30 °C (if the temperature is about 40 °C, the storage period should not exceed 6 months; About 50°C, the storage period does not exceed 3 months).
2) Maintenance
Because the main circuit and control circuit of the inverter use more electrolytic capacitors, if not used for a long time, the leakage will increase, the withstand voltage will decrease, that is, accelerate the deterioration (the higher the temperature, the faster the deterioration), therefore, at least once a year, the external power supply is added, so that the repair power-on time is 30-60min, the characteristic is that only the inverter monomer is energized (without connecting the motor), and the input end of the inverter can be connected to the power supply.
|
More on that
|
Analysis of the problem of excessive current of LS three-phase motor for power generation
First, the power supply problem
1. The power supply voltage is too high
When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...
|
|
Relationship between motion control and frequency converter
Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller.
...
|
|
Safety precautions for LS inverters
1. When the power supply is now powered or the inverter is in operation, do not open the shell of the inverter. Otherwise, an electric shock may occur.
2. When the front cover of the inverter is opened, do not run the inverter. Otherwise, you may be subjected to ...
|
|
Inverter carrier frequency adjustment method - LS power generation
A. The output voltage of the SPWM inverter is a series of pulses, and the pulse frequency is equal to the carrier frequency.
B. In the current of the motor, there is a harmonic component with a strong carrier frequency, which will cause the vibration of the motor core and announce the noise. If the frequency of the noise is the same as that of the motor core.
|
|
Analysis of heat dissipation problems of inverter - LS power generation
In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...
|
|
Debugging of basic parameters of inverter - LS power generation
There are many functional parameters of the inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to set and debug every parameter, and most of them only need to use the factory setting value. However, some parameters are very closely related to the application of practice, and some of them are still ...
|
|
What are the categories of PLC products?
The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...
|
|
Faulty failure with soft starter - LS generates electricity
In the use of soft starters, some users often have some wrong concepts:
1. It is believed that whether the motor can be started successfully is related to the function of the soft starter, and a good brand or even a foreign brand should be selected under heavy load.
2. When the motor is not ...
|
|
The wiring distance between the motor and the inverter
Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...
|
|
The given way of the inverter - LS generates electricity
Frequency given meaning and given method
The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal.
|
|
A brief description of the K120S series plc
K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise.
...
|
|
PLC installation and wiring skills - LS power generation
The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances.
Power cables, control cables, and PLC power cables and I/O cables should be separated from the wiring ...
|
|
LS automatic gain adjustment for power generation
In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs.
Azimuth Share Buff:
1. Set the share gain of the azimuth ring adjuster;
2 ...
|
|
Parameter setting of LS power inverter
Control method: i.e. speed control, rotation control, PID control or other methods. After adopting the control method, it is generally necessary to carry out static or dynamic identification according to the control accuracy and requirements. Low operating frequency: that is, the small speed of the motor running, when the motor is running at low speed, its heat dissipation function ...
|
|
Common faults in terminal blocks - LS generates electricity
From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common types of faults in terminal blocks:
...
|
|
Quickly locate the fault method of switching power supply - LS power generation
Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...
|
|
Cycloidal reducer transmission system testing - LS power production
With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects.
...
|
|
The selection principle of AC contactors - LS produces electricity
1. The voltage level of the AC contactor should be the same as the load, and the type of contactor should be suitable for the load.
2. The accounting current of the load should be less than or equal to the additional working current of the contactor.
The turn-on current of the contactor is greater than the starting current of the load, and the breaking current is greater than the load ...
|
|
The cause and inspection method of inverter overload tripping - LS power generation
1. The main reason for the overload of the inverter
(1) Malfunction, the current detection part inside the inverter has a problem, and the detected current signal is too large, resulting in tripping.
(2) The mechanical load is overloaded, and the main feature of the overload is that the motor heats up, and it can be ...
|
|
LS power terminal is faulty
From the perspective of application, the function of the terminal block should be achieved: the contact part should be conducted, and the contact should be reliable. The insulating parts should not be conducted, and it is necessary to insulate them firmly. There are three common forms of fatal failure of terminal blocks:
...
|
|