LG Inverter-LS Inverter-IGXA Sales

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

LG Inverter LS Inverter IGXA Series ** for sale, its models are as follows:

                               LG Inverter-LS Inverter-IGXA Sales

SV004IGXA-4 60210101W0 Power 0.37KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV008IGXA-4 60210102W0 Power 0.75KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV015IGXA-4 60210103W0 Power 1.5KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV022IGXA-4 60210104W0 Power 2.2KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV037IGXA-4 60210105W0 Power 3.7KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV040IGXA-4 60210106W0 Power 4.0KW (Input: 3-phase 380V / Output: 3-phase 0-380V)
SV055IGXA-4 60210107W0 Power 5.5KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV075IGXA-4 60210108W0 Power 7.5KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV110IGXA-4 60210109W0 Power 11KW (Input: 3-phase 380V / Output: 3-phase 0-380V)
SV150IGXA-4 60210110W0 Power 15KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV185IGXA-4 60210111W0 Power 18.5KW (Input: 3-phase 380V / Output: 3-phase 0——380V)
SV220IGXA-4 60210112W0 Power 22KW (Input: 3-phase 380V / Output: 3-phase 0-380V.)
SV004IGXA-4N 60210113W0 Power 0.37KW (Input: 3-phase 380V / Output: 3-phase 0-380V) without panel.
SV008IGXA-4N 60210114W0 Power 0.75KW (Input: 3-phase 380V / Output: 3-phase 0-380V) without panel.
SV015IGXA-4N 60210115W0 Power 1.5KW (Input: 3-phase 380V / Output: 3-phase 0-380V) without panel.
SV022IGXA-4N 60210116W0 Power 2.2KW (Input: 3-phase 380V/ Output: 3-phase 0-380V) without panel.
SV037IGXA-4N 60210117W0 Power 3.7KW (Input: 3-phase 380V / Output: 3-phase 0-380V) without panel
More on that
Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

The choice of inverter power - LS produces electricity The choice of inverter power - LS produces electricity

1. The power value of the inverter is the most suitable for the power value of the motor, so as to facilitate the operation of the inverter at a high power value. 2. When the power classification of the inverter is not the same as the power classification of the motor, the power of the inverter should be as much as possible.

The main functions and functions of LS power production PLC The main functions and functions of LS power production PLC

1. For sequential control: sequential control is based on the current and pre-historical conditions of the input switch, and produces the required switching output, so that the system can work in a certain order. This is the basic manipulation of the system. It is also a common manipulation in discrete production processes. ...

Common faults in terminal blocks - LS generates electricity Common faults in terminal blocks - LS generates electricity

From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common types of faults in terminal blocks: ...

The method of resetting the fault of the inverter The method of resetting the fault of the inverter

1. Power off the inverter and power it back on; 2. Press the FN button on BOP-2; 3. After the digital input 3, the default setting of 3 is reset to the problem; 4. Press the P button or power off, in the case of no problem; ...

Precautions for the peripheral configuration of the inverter - LS generates electricity Precautions for the peripheral configuration of the inverter - LS generates electricity

(1) When the inverter is connected to the power grid of large-capacity power transformer (more than 500kVA), perhaps the same power transformer is connected with a thyristor converter without using a commutation reactor, or when there is a switching capacitor bank for power improvement in the same power grid, an AC reactor or DC reactor should be equipped.

How does the interference of the frequency converter occur? -- Electricity production How does the interference of the frequency converter occur? -- Electricity production

To discuss the disturbance problem of LS inverter, we must first understand the operating principle of inverter, from the structural point of view, inverter is divided into direct inverter and direct inverter. The direct inverter is a communication that directly converts the I frequency current into a controllable frequency, and there is no intermediate DC link. Each phase of it ...

The vector control mode of low-voltage general-purpose inverter - LS power generation The vector control mode of low-voltage general-purpose inverter - LS power generation

The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.

The main structure of LS power AC contactor The main structure of LS power AC contactor

The operating principle of the contactor is: when the contactor coil is energized, the coil current will generate a magnetic field, and the generated magnetic field will make the static iron core attract the moving core with electromagnetic attraction, and drive the communication contactor point action, the normally closed contact is disconnected, and the normally open contact is closed, and the two are linked. When the coil is de-energized ...

Inverter circuit structure - LS generates electricity Inverter circuit structure - LS generates electricity

The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...

The interference phenomenon of the inverter - LS power generation The interference phenomenon of the inverter - LS power generation

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is interfered by the inverter; 3. When the inverter starts the motor, the voltage transformer signal is unstable ...

Introduction of LS power products Introduction of LS power products

1. Power-related products: medium, low and high voltage electrical products; (1) Low Voltage Products: Molded Case Circuit Breaker, Air Circuit Breaker, LS Contactor & Overload Relay, Miniature Circuit Breaker, Dual Power Automatic Transfer Switch, Intelligent Motor Protector, Manual Motor Starter, Surge Protection ...

LS power inverter parts replacement and its requirements LS power inverter parts replacement and its requirements

The inverter is composed of many electronic parts, such as semiconductor components, etc., in the operation and maintenance involves the replacement of a related component, because of the composition or physical characteristics of the inverter, it will deteriorate in a certain period of time, so it will reduce the characteristics of the inverter, and even ...

The difference between LS power inverter and servo The difference between LS power inverter and servo

An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation. 1. What the two have in common: The AC servo technology itself is to learn and apply the technology of frequency conversion, and the servo control of the DC motor is based on the ...

The advantages of the inverter in practical application - LS power generation The advantages of the inverter in practical application - LS power generation

With the continuous progress of industrial automation, inverters have also been widely used, energy conservation and environmental protection as the core of China's industrial economy, in the direction of the sustainable development of China's industry, but also useful to promote the sustainable development of China's inverter profession, so that I ...

Power production PLC installation and wiring skills Power production PLC installation and wiring skills

The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances. Power line, control line and PLC power line and I/O line should be separated from the wiring, barrier transformer and PLC and I/O should be selected ...

Inverter circuit board repair and drawing-free maintenance method - LS power generation Inverter circuit board repair and drawing-free maintenance method - LS power generation

1. Be "confident" It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...

LS inverter frequency conversion mode LS inverter frequency conversion mode

1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...

Inverter applications and common loads – LS generates electricity Inverter applications and common loads – LS generates electricity

1. Air conditioning load Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, with inverter equipment, drag the air conditioning system ...

The difference between multi-function and general-purpose inverters The difference between multi-function and general-purpose inverters

Multi-function inverters need to meet the following two conditions: First, it can be driven by constant torque load, regardless of the type of machine, and can ensure continuous operation even if the load fluctuates greatly. If the above conditions are not satisfied, the inverter will be easy to stop, difficult to start again, and resistant to ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top