Why can't the inverter be equipped with a leakage protector - power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters.

                               Why can't the inverter be equipped with a leakage protector - power generation

Some users choose the corresponding leakage maintainer for the inverter when using the inverter. * The result is that the inverter moves together, the leakage maintainer acts, and the system cannot operate at all. Why?
  ​
The principle of a leakage maintainer is that the zero sequence current is zero. When using an inverter, the zero sequence current cannot be zero.

The output side of the inverter is a PWM wave, and there is a capacitive effect of a long cable between the motor cable and the ground, which is more pronounced when using a shielded cable. During the operation of the inverter, the capacitor is charging and discharging, and the current flows into the ground through the capacitor, and flows back to the inverter from the grounding wire on the incoming side to form a current loop. If a leakage maintainer is used on the incoming side, it will operate and cut off the system. So, don't equip your drive with a leakage maintainer. If you want to ensure safety, just do a good job of grounding the equipment.

Example: Q: An 18.5KW boiler induced draft fan is installed with an 18.5KW inverter, as soon as the inverter is started, the power distribution room will jump when it is opened, and the original power distribution room is equipped with a leakage maintainer (200mA action, 30mA pulse). The customer was asked to remove the leakage maintenance was refused, and then the carrier frequency was adjusted to 1KHz, and the starting method of the inverter was still not dealt with, * After the doubt that the power line of the motor has leakage, because its length is about 20 meters and buried in the ground, but it is also difficult to require the customer to replace it (its original power frequency is used normally). Is there a brief and useful way to deal with it?

Answer: Because the leakage maintainer generally detects that the three-phase unbalance is more than %20, it will skip maintenance, and when the three-phase unbalance degree is installed after the inverter, the three-phase unbalance will generally exceed %50 or more, so the leakage maintainer will definitely jump.

Here are a few ways to do it:

Method 1: There will generally be an adjuster on the leakage maintainer, and the regulator can be adjusted to a larger size.

Method 2: Replace the leakage maintainer with a special leakage maintainer for the inverter, and there are special leakage maintainers for the inverter on the market.

Method 3: Increase the load of the equipment, that is, the load of the motor, and the leakage current of the inverter will not be very large when it is started.

Method 4: Short the leakage maintainer.
More on that
Classification of the nature of DC power supply of inverter - LS power generation Classification of the nature of DC power supply of inverter - LS power generation

A frequency converter is actually an inverter. It starts by turning alternating current into direct current. Then the direct current is switched on and off with electronic components. Becomes alternating current. Thyristors for general inverters with larger power. And set up a device with adjustable frequency. Make the frequency adjustable within a certain range. Used to control ...

The meaning of power in LS power inverter The meaning of power in LS power inverter

Power refers to the amount of work done by an object in a unit of time, i.e., power is a physical quantity that depicts how fast or slow work is done. The amount of work is constant, and the shorter the moment, the greater the power value. The formula for finding power is power = work/moment. Power is a physical quantity that characterizes the degree of work done fast or slow. Units made in the hour ...

Faulty failure with soft starter - LS generates electricity Faulty failure with soft starter - LS generates electricity

In the use of soft starters, some users often have some wrong concepts: 1. It is believed that whether the motor can be started successfully is related to the function of the soft starter, and a good brand or even a foreign brand should be selected under heavy load. 2. When the motor is not ...

Analysis of heat dissipation problems of inverter - LS power generation Analysis of heat dissipation problems of inverter - LS power generation

In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...

Inverter fault diagnosis - LS power generation Inverter fault diagnosis - LS power generation

1. How to distinguish between heavy and light faults When there is a problem with the light, the system announces the alarm signal and the fault indicator flashes. When there is a serious problem, the system will announce the problem indicator, the problem indicator will always be on, together announce the order to break the high voltage and stop closing, and store the problem ...

Analysis of common faults of LS AC contactors Analysis of common faults of LS AC contactors

AC contactor is generally used to turn on or off the power supply in the control circuit of electromechanical equipment, it can frequently turn on or off the AC circuit, and can realize long-distance control. The toucher is mainly composed of a contact system and an electromagnetic system, and the problem of AC contactor is generally generated in the coil.

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Specifications for the use of power converters Specifications for the use of power converters

Operating regulations for power inverters   Maintenance & Installation Work according to the weight of the product. The number of inverter boxes cannot be stacked in excess of the specified number. Install according to the user manual. Do not open the case during transport. Do not place ...

Failure analysis of electromagnetic system of LS power production contactor Failure analysis of electromagnetic system of LS power production contactor

(1) The core noise is large: it is normal for the electromagnetic system to produce a slight humming sound during operation, if the sound is too loud or abnormal, it can be judged that the electromagnetic system has a problem, and there are three reasons: (1) Poor contact between the armature and the core or tilting of the armature. After repeated collisions between the touch of the armature and the core, ...

Whether the C-type circuit breaker is suitable for the motor circuit - power generation Whether the C-type circuit breaker is suitable for the motor circuit - power generation

Type C micro-break is used for general circuits, such as lighting circuits; D-type circuit breakers are used in power circuits such as electric motors, so can C-type micro-breakers be used in motor circuits? Differences between C-type and D-type discontinuity: C-type micro-disconnect: with ...

Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

Contactors play a role in industrial electricity Contactors play a role in industrial electricity

The contactor is an automatic switch for industrial roofs to control its on/off with a button. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

Single-table driver for HLP2B Single-table driver for HLP2B

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

(1) Tripping LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a tripping method of thermomagnetic tripping or electronic tripping. In the process of practical application, if it is a ...

The touch screen controls the inverter steps The touch screen controls the inverter steps

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

The production power takes you to read the PLC ladder diagram The production power takes you to read the PLC ladder diagram

1. Trapezoidal stairs start from the horizontal line and end up with a vertical line (generally you can omit not to draw, only draw the left busbar). On the left side of each row is the junction combination, indicating the conditions that drive the logic coil, while the logic coil indicating the effect can only be connected to the bus on the right. The contact can not appear in the coil right ...

The size of the contactor is selected by the type of contactor - LS produces electricity The size of the contactor is selected by the type of contactor - LS produces electricity

1. Select the corresponding category of contactor according to the control object, operation times and application category of the contactor. 2. Select according to the rated voltage of the line at the application location. 3. Select the rated current of the main contact of the contactor according to the load capacity. 4. About the voltage level of the lead coil ...

The cause and inspection method of inverter overload tripping - LS power generation The cause and inspection method of inverter overload tripping - LS power generation

1. The main reason for the overload of the inverter (1) Malfunction, the current detection part inside the inverter has a problem, and the detected current signal is too large, resulting in tripping. (2) The mechanical load is overloaded, and the main feature of the overload is that the motor heats up, and it can be ...

After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power

What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized? In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...

The cause of the failure of low-voltage electrical appliances - LS power generation The cause of the failure of low-voltage electrical appliances - LS power generation

In the control circuit of low-voltage electrical appliances, there are simple low-voltage components such as: buttons, safe, etc.; There are also slightly messy low-voltage electrical control components, such as circuit breakers, touch devices, time relays, thermal relays and other simple components, which makes it necessary to diagnose and analyze the cause of the problem. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top