Peel magnetic relay - the cause and solution of the fault of the high voltage relay

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

1. Some common faults of high-voltage relay coils

1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.

2. The common fault reasons for the lack of power engineering in the coil are: first of all, the working voltage of the high-voltage relay coil must be determined, and it is assumed that the working voltage of the power supply system to the coil is lower than the posture working voltage, which will cause the contact to be out of posture.

3. Common fault causes of coil optical rotation connection: check whether the diode equipped with the high voltage relay is equipped with optical rotation error, which will make the contact not operate.

4. Appear coil communication AC with; The DC DC power supply system is incorrect, and common fault reasons: if the AC voltage is added to the high-voltage relay coil of the AC coil, then there will be a hot coil, which is very likely to cause ablation, and if the AC current is added to the high-voltage relay coil of the DC coil, it will make the moving iron sheet vibrate continuously and then cannot work normally.

5. If a part of the coil is connected to the power supply for a long time, it will lead to the hot coil and the malignant transformation of the insulation layer, which will promote the common fault of the high-voltage relay posture.

Second, some common fault solutions for high-voltage relay coils

1. A simpler and better way is to disassemble and replace the high-voltage relay again.

2. There is also to determine the working voltage of the coil to prevent the working voltage supplied by the coil from being less than the working voltage.
Peel magnetic relay - the cause and solution of the fault of the high voltage relay

More on that
Pierz: The safety protection of the press can be so neat! Pierz: The safety protection of the press can be so neat!

1. Presses = inflexible? In the past, presses were often labelled as "sluggish", "inflexible" and "high-risk". With the development of technology, safety solutions for presses are emerging one after another, and the safety of presses is greatly improved. In the event that security is ensured...

Pilz will be exhibiting at LogiMAT 2023 Pilz will be exhibiting at LogiMAT 2023

From April 25 to 27, at the LogiMAT international logistics trade fair in Stuttgart, Germany, Pilz will present its safe and complete AGV safety automation solutions.   At Pilz's booth in Hall 6 – A21, visitors to the show will experience how AGVs are considering ...

Pilz – how safety light curtains are safe to install Pilz – how safety light curtains are safe to install

1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...

The working principle and characteristics of Pilz safety relays The working principle and characteristics of Pilz safety relays

Pilz safety relays generally consist of an iron core, a coil, an armature, a contact reed, etc. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect. Under the action of electromagnetic attraction, the armature overcomes the pulling force of the return spring and sucks in the iron ...

Pilz leads the publication of the HRC Safety Application Guide Pilz leads the publication of the HRC Safety Application Guide

With the increasingly widespread use of industrial robots, the trend of China's manufacturing industry to a higher degree of automation has been bright, and the transformation and upgrading of China's manufacturing industry is on the way. The emergence of collaborative robots means that more intelligent robots will become the future intelligent system of China's manufacturing enterprises.

Peel magnetic relays – testing of relays Peel magnetic relays – testing of relays

(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open. (2) Coil resistance: multimeter R...

Pilz: Safety light curtains for hand protection Pilz: Safety light curtains for hand protection

The tightly meshing beam field of the safety light curtains PSENopt and PSENopt II is ideally suited for all applications where hand protection is required. By placing the safety light curtain close to the danger zone, the operator can be optimally protected and the workflow will not be interrupted, making it ideal for spaces with ...

PILZ WILL BE EXHIBITING AT THERMPROCESS 2023 PILZ WILL BE EXHIBITING AT THERMPROCESS 2023

From June 12 to June 16, 2023, Pilz will be present at the THERMPROCESS trade fair in Düsseldorf, Germany, at booth B10 in Hall 9. Germany Düsseldorf Thermprocess is Germany most important trade fair for industrial furnaces and heat treatment ...

Peel magnetic relays – how thermal relays control contactors Peel magnetic relays – how thermal relays control contactors

The main function of a thermal relay is to protect the motor. The new electronic thermal relay has protection against overload, overcurrent, blocked rotor and various phase faults, current unbalance, interphase short circuit, inter-turn short circuit or overvoltage, undervoltage and so on. In the process of using thermal relays, we should ...

Pilz won the China Machinery Industry Science and Technology Award Pilz won the China Machinery Industry Science and Technology Award

Recently, Pilz won the China Machinery Industry Science and Technology Award jointly issued by the China Machinery Industry Federation and the China Mechanical Engineering Society, in recognition of Pilz in the "Machinery Safety Hazardous Energy Control Method Locking/Listing (GB/T33579-2017 Standard Number) Standard Formulation, Application and Publicity...

Pilz: It's easy to build your own customised safety relay Pilz: It's easy to build your own customised safety relay

The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience. ...

REPAIR OF PILZ SAFETY RELAYS REPAIR OF PILZ SAFETY RELAYS

AS MENTIONED EARLIER, PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. When the locomotive is running, when the motor, electrical appliances or connection lines in the main circuit and auxiliary circuit fail, the fault can be replaced by the Pilz safety relay of the corresponding monitoring and protection system.

Common faults of Pilz safety relays with contacts and how to deal with them Common faults of Pilz safety relays with contacts and how to deal with them

The most common ones are the following: (1) Contact failure 1. The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion formed on the contact and the pit biting each other), fusion welding, or cold welding. 2. Due to the contact resistance becoming large and unstable, the circuit cannot be normal ...

IEC 62443 – Industrial Information Security Standard – Pilz IEC 62443 – Industrial Information Security Standard – Pilz

The development of IT technology is changing all walks of life, automation is no exception, the degree of networking of production equipment and the use of standard protocols such as Ethernet for physical transmission of data has greatly increased, standardized protocols such as OPC UA allow access to controllers through IT systems, making data communication changeable.

Pilz: Safe monitoring of cardboard feeds for packaging machines Pilz: Safe monitoring of cardboard feeds for packaging machines

Pilz supports manufacturers and operators of packaging machines in the implementation of packaging automation. As a well-known and trusted provider of machinery safety services to companies worldwide. Use the myPNOZ modular safety relays The first ...

Pilz: Buying VS Retrofit? Take a look at the selection of the Austrian company Pilz: Buying VS Retrofit? Take a look at the selection of the Austrian company

When part of the production line no longer meets the current production needs, do you choose to buy new equipment or modify old equipment? Scheucher, a hardwood flooring manufacturer based in Austria, was faced with such a choice not so long ago. In Scheuch ...

Pilz: How exactly does Key in pocket work? Pilz: How exactly does Key in pocket work?

Key in Pocket has attracted attention since its introduction as an alternative to tagout lockout, as it not only improves work safety and optimizes workflows, but also provides convenience and productivity for workers in the field. Key in pocket is actually IAM ( ...

Pilz: A new version is here! This time it's more powerful Pilz: A new version is here! This time it's more powerful

Since its launch, Pilz's flagship product, the configurable and safe small controller PNOZmulti, has been impressed by users for its robustness, flexibility and ease of operation. PNOZmulti Configurator as a configuration tool for the safe small controller PNOZmulti ...

Pierre Switches – An introduction to the basics of safety switches Pierre Switches – An introduction to the basics of safety switches

Features of the safety door switch: The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...

Classification of Pilz safety relays Classification of Pilz safety relays

Safety relays from PNOZ – a classic In 1987, Pilz was a milestone in the development of the world's first emergency stop safety relay to protect people and machines. PNOZ has also become synonymous with safety relays and is used by customers all over the world. The full range ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top