Description: Retroreflective sensor ML100-55/103/115a photoelectric sensor with polarization filter, plastic housing, 5 m detection range, red light, adjustable sensitivity, on/dark, DC, PNP output, fixed cable with M8 plug.
Product Details
Effective detection distance 0 ... 5 m
The distance of the reflector is 0,01 ... 5 m
The limit value of the detection range is 7 m
Reference target H50 reflector
Light source LED
Light source type Modulates visible red light
Polarization filters Yes
The light spots are approximately 500 mm in diameter and 7 m apart
The divergence angle is approximately 4 °
Optical end face Straight forward
Ambient light limit EN 60947-5-2:2007+A1:2012
Functional safety-related parameters
MTTFd 860 a
Mission time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicator/method of operation
Working Indicator Green LED: Power on
Function Indicator Yellow LED: Lights up when receiving the beam; Flashes when stability control is insufficient; Turn off when the beam is interrupted
Control Element Sensitivity Adjustment
Control element Turn on when on/turn on when dark
Electrical Specifications
Operating voltage 10 ... 30 V DC
Ripple max. 10 %
No-load current < 20 mA
output
Switch Type The switch type of this sensor is changeable. The default setting is: Switch on when on
Signal output 1 PNP output, short circuit protection, reverse polarity protection, open collector
Switching voltage max. 30 V DC
Switching current max. 100 mA, impedance load
Voltage drop ≤ 1,5 V DC
Switching frequency 1000 Hz
Response time 0,5 ms
compliance
The product standard is EN 60947-5-2
Certifications and certificates
UL listed cULus certified Class 2 power supplies, or certified power supplies with limited voltage output with (can be integrated) fuses (3.3 A max, UL248 compliant), Class 1 enclosures
CCC Certification For rated voltages of ≤ 36 V, the product does not require CCC certification/marking
Environmental conditions
Ambient temperature -30 ... 60 °C (-22 ... 140 °F)
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Mechanical Specifications:
Housing width 11 mm
Housing height 31 mm
Housing depth 20 mm
Degree of protection IP67
Connection 300 mm fixed cable with M8 connector, 4-pin
material
Housing PC (Polycarbonate)
Optical end-face PUMA
Mass approx. 20 g
Tightening torque of the tightening screws 0,6 Nm
Cable length 0,3 m
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the P+F/Mega Reflector Sensor ML100-55/103/115a 7 m product, if you are interested in P+F/Mega Reflector Sensor, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
P+F/Encoder RVI50N-09B**A*T 80mA
Introduction: An incremental encoder provides a fixed number of pulses in one revolution, and the speed is calculated by the number of pulses measured per unit of time. To measure angles and positions, it is common to start counting from a starting reference point. The accuracy of incremental encoders depends on mechanical and electrical factors ...
|
|
P+F/Through-beam photoelectric sensors LD31/LV31/76a/115/136
Product Description: Thru-beam sensor, 30 m detection range, red, low, DC version, 2 push-pull outputs, transmitter off, fixed cable, high visibility LED, powerful push-pull output, compact and stable housing, degree of protection II
Our customer-centric ...
|
|
P+F/Capacitive sensor CJ4-12GK-N 4mm non-flush
Introduction: Capacitive sensors can be used to detect targets in almost any material, including metal. These sensors are used in a wide range of applications for level and flow control, mainly liquids, particles and powders.
...
|
|
P+F/GZ Sensor GL10-RT / 30 / 40A / 98A
Product introduction: There is a special through-beam sensor in our products called fork sensor. It is mainly used in places where the measurement distance is short. Since only one device requires wiring, fork sensors have the advantage of being easy to install compared to standard control sensors. ...
|
|
P+F/Throughbeam GD18 / GV18 /73/120
Product Introduction: Thru-beam sensor, M18 threaded housing design, plastic housing, front optical face, 20m detection distance, red light, light and dark, DC version, 2 PNP outputs, M12 plug, high efficiency line, short M18 plastic housing application, very high detection range, 4 LEDs ...
|
|
P+F/Print Marker Luminescence Scanner DK50-UV-190 / 115B / 147
Product Introduction: Color is usually the distinctive feature of a product, so color recognition and reliable detection play an increasingly important role in industrial automation. The color sensors of P+F are very good and cover most applications, e.g. for fixed detection distances.
|
|
P+F/Inductive sensor NBN4-12GM50-E2-V1-Y89925
Introduction: Germany P+F/Beijiafu inductive sensor is the use of electromagnetic induction to measure physical quantities such as displacement, pressure, flow, vibration, etc. into the change of the self-inductance coefficient and mutual inductance coefficient of the coil, and then converted by the circuit into the output of voltage or current change, to achieve non-electric to electric ...
|
|
P+F/Inductive sensor NBN4-12GK50-E0/E2 voltage drop ≤3V
Introduction: Germany P+F/Beijiafu inductive sensor is the use of electromagnetic induction to measure physical quantities such as displacement, pressure, flow, vibration, etc. into the change of the self-inductance coefficient and mutual inductance coefficient of the coil, and then converted by the circuit into the output of voltage or current change, to achieve non-electric to electric ...
|
|
P+F/Inductive sensor NBN4-F25K-2E2/2Z4L/E8 4mm
Introduction: Germany P+F/Beijiafu inductive sensor is the use of electromagnetic induction to measure physical quantities such as displacement, pressure, flow, vibration, etc. into the change of the self-inductance coefficient and mutual inductance coefficient of the coil, and then converted by the circuit into the output of voltage or current change, to achieve non-electric to electric ...
|
|
P+F/Optical Fiber Optic Sensors SU18/16/35/40a/110/115/126a
Product Introduction: Fiber Optic Sensors for Glass and Plastic Fibers, Basic Production Line for DIN Rail Mounting, High Power Version, Sleek Design, Selectable 3 Response Times, Mutual Interference Prevention (No Crosstalk)
Detailed parameters:
...
|
|
P+F/Capacitive sensor CBN5-F46-E2-10M 5mm
Introduction:P+F Capacitive Sensor CBN5-F46-E2-10M Flat Housing; reverse polarity protection; Fixing slot for cable tie, through-hole for screw mounting, cULus listed, general use.
Product parameters
...
|
|
P+F inductive sensor NBN4-F25K-E8 4 mm
Introduction: Smooth or threaded stainless steel cylindrical housing for standard inductive sensors; reverse polarity protection and short circuit protection; LED status indicates M8, M12 connector connection or terminal wiring mode; PVC, PUR or silicon cable outlet; 2-wire, 3-wire, 4-wire DC, AC, NAMUR output ...
|
|
P+F/Capacitive sensor NTK-H has a conductor cross-section of 0,34 mm2
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Capacitive sensor CJ10-30GM-WS current: 5~200mA
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Triangulation sensor OQT150-R101-2EP-IO 150 mm
Product Introduction: Switching sensors with measurement core technology have an enhanced range of functions. Based on the Multipixel Technology (MPT) developed by Pepperl + Fuchs, multiple operating modes and switching points can be easily set in a single triangulation sensor. These photoelectric ...
|
|
P+F/Through-beam photoelectric sensor OBE500-R2F-SE2 500 μs
Description: OBE500-R2F-SE2 through-beam photoelectric sensor, low profile design, space-saving M2 mounting, 500 mm detection range, red light, dark on, PNP output, fixed cable.
Product parameters
Effective detection ...
|
|
P+F/MLV11-8-500-Ex/40b/112 60g
Description: The P+F/Photoelectric Sensor MLV11-8-500-Ex/40b/112 is ATEX certified for Zone 1 (gas); Intrinsically safe, explosion-proof operating specification IA IIC T6 Gb; Diffuse photoelectric sensors for standard applications; Sensitivity adjustable.
...
|
|
P+F/Logic control devices up to 100 kHz
Introduction: Logic control units are widely used in the automation industry. In practice, they are capable of detecting digital or analog signals, displaying them and monitoring them. In order to solve the conversion and application between signals, we provide digital display meters, counters ...
|
|
P+F/Background Suppression Sensor MLV41-8-HV-60-IR-5360
Product Description: Visolux/ Pepperl+Fuchs has developed a range of special sensors for industrial use that extend the range of applications for common sensors. These special photoelectric sensors allow the customer to find a more suitable solution.
Specifications:
...
|
|
P+F/UB120-12GM-E5-V1 connector M12
Product Introduction: The transducers used to transmit and receive sound waves are separated, so that the system does not need to wait for the signal attenuation of the transmitter, thus effectively reducing the dead zone. The direct detection type of ultrasonic sensors is available with switching and analog outputs. Direct detection of all support window mode functions ...
|
|