Product Description: Thru-beam sensor, 30 m detection range, red, low, DC version, 2 push-pull outputs, transmitter off, fixed cable, high visibility LED, powerful push-pull output, compact and stable housing, degree of protection II
Product Description | Thru-beam photoelectric sensor, 30 m detection range, red light, dark on, DC type, 2 push-pull outputs, transmitter off, fixed cable |
System components | Transmitters | LD31/76a/115 | receiver | LV31/115/136 | General specifications | Effective detection distance | 0 ... 30 m | Detection range limit values | 43 m | light source | LED | The type of light source | Modulated visible red light, 630 nm | Alignment aids | Yellow LED:
1. LED on: Enough light signal is received, and the transmitter and receiver are properly aligned
2. LED flashing: Reach the switch point
3. LED off: The beam is interrupted or misaligned | Spot diameter | Approximately 800 mm are 30 m apart | Divergence angle | Transmitter: 1,5 ° , Receiver: 1,5 ° | Ambient light limitations | 50000 Lux ; According to EN 60947-5-2 | Functional safety-related parameters | MTTFd | 750 a | Mission Time (TM) | 20 a | Diagnostic Coverage (DC) | 90 % | Indicator/method of operation | Work indicator | Green LED: Powered on | Function indicator | Yellow LED:
1. LED is always on: signal > 2 x switching points (function reserved)
2. LED flashing: The signal is between 1 x switch and 2 x switch points
3. LED off: signal < switch point | Electrical Specifications | Operating voltage | 10 ... 30 V DC | Ripple | 10 % | No-load current | Transmitter: ≤ 18 mA
Receiver: ≤ 18 mA | input | Test inputs | Under +UB the emitter is deactivated | output | Switch type | Turn on when dark | Signal output | 2 push-pull (4-in-1) outputs, short-circuit protection, reverse polarity protection | Switching voltage | 30 V DC max | Switching current | 100 mA max | Voltage drop | ≤ 1,5 V | Switching frequency | ≤ 250 Hz | Response time | ≤ 2 ms | compliance | Product standards | EN 60947-5-2 | Certifications and certificates | Ingress protection | II, When the pollution class is 1-2 (according to IEC 60664-1), the rated voltage is ≤ 250 V AC The output circuit of the input circuit is basically insulated according to EN 50178 and the rated insulation voltage is 240 V AC | UL recognized | cULus recognized, Class 2 power supply, Class 1 enclosure | CCC certified | At a rated voltage of ≤ 36 V, the product does not require CCC certification/marking | Environmental conditions | Ambient temperature | -30 ... 55 °C (-22 ... 131 °F) | Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | Mechanical Specifications: | Enclosure width | 18 mm | Enclosure height | 62 mm | Enclosure depth | 35 mm | Ingress protection | IP67 | connect | Transmitter: 2 m fixed cable, 3 wires
Receiver: 2 m fixed cable, 4 wires | material | | | enclosure | polycarbonate | | Optical end faces | PUMA | quality | Transmitter: 98 g
Receiver: 132 g |
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces P+F/Bulb Photoelectric Sensor LA31/LK31/25/31/115 products, if you are interested in P+F/P+F/Bulb Photoelectric Sensor, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
P+F/Print Marker Luminescence Scanner DK50-UV-190 / 115B / 147
Product Introduction: Color is usually the distinctive feature of a product, so color recognition and reliable detection play an increasingly important role in industrial automation. The color sensors of P+F are very good and cover most applications, e.g. for fixed detection distances.
|
|
P+F/Bi-material sensor UDC-18GM50-255S-3E0
Product Introduction: Ultrasonic double sheet detector is used to automatically and at high speed to distinguish substrate materials, labels, sheet-fed and double-fed, so as to protect the machine from waste in the production process. The whole system consists of an ultrasonic transmitter, an ultrasonic receiver and an external or built-in ...
|
|
P+F/Capacitive sensor CBN15-F64-A2 voltage drop ≤2V
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards the proximity switch, whether it is ...
|
|
P+F capacitive sensor CBB10-30GKK-A2 10mm flush
Introduction:P+F Capacitive Sensor CBN5-F46-E2-10M Flat Housing; reverse polarity protection; Fixing slot for cable tie, through-hole for screw mounting, cULus listed, general use.
Product parameters
...
|
|
P+F/Retroreflective Sensor GLV18-55/73/120 10~30 V DC
Product Description: Retroreflective sensor with polarization filter, M18 threaded housing design, plastic housing, front optical face, 4 m detection range, red light, light and dark on, DC type, 2 PNP output, fixed cable, high-efficiency wire in M18 plastic housing Standard application, very high detection range
|
|
P+F Barrier Module H Series Width 18mm
Introduction: The H-Series can be connected to hazardous area field devices and control systems by mounting multiple isolation barriers on terminal boards. Compared to a single interface module, the terminal block greatly simplifies wiring and saves costs. The terminal block is equipped with a sturdy plastic housing for quick and secure installation in the cabinet. ...
|
|
P+F/Logic Control Device 14bit Resolution
Introduction: Logic control units are widely used in the automation industry. In practice, they are capable of detecting digital or analog signals, displaying them and monitoring them. In order to solve the conversion and application between signals, we provide digital display meters, counters ...
|
|
P+F/Optical Data Coupler LS682-DA-EN / F1 Fast Ethernet
Product Introduction: The optical communication system supports two-way communication between storage and retrieval systems, transmission vehicles, automatic guided vehicles and monorail conveyors. This is an alternative to complex and problematic cables, slip rings and other transmission solutions. The transmission between the two sites is replaced by infrared light, which is made up of several ...
|
|
P+F/Optical fiber optic sensor SU19.1/110/115 30μs
Product Introduction: Classic Series Fiber Optic Sensor with Display, Slave Module, Push-Pull Output, Fixed Cable, Classic Line with Display, AGC (Automatic Gain Control) for Faster Teach-in, Combined Installation, Easy Wiring, Transparency Recognition, 30μs High Speed Mode.
...
|
|
P+F capacitive sensor CJ10-30GK-WS housing diameter 30 mm
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F inductive sensor NBN5-F7-E0 5 mm non-flush
Introduction: P+F inductive sensor NBN5-F7-E0 5 mm non-flush, switch function normally open (NO), output type NPN, rated working distance 5 mm, installation non-flush, output polarity DC, ensure operating distance 0 ... 4,05 mm
...
|
|
P+F/Beam Ultrasonic Barrier UBE1000-18GM40A-SE2-V1
Introduction: There is no electrical connection between the transmitter and receiver, and while the sensor is mounted in such a way that it does not affect the functionality of the ultrasonic through-beam sensor, it is recommended to mount the transmitter face up when the sensor is mounted vertically to prevent the accumulation of dust particles.
...
|
|
P+F/DK10-LAS/35/49 Laser Class 2
Product Introduction: Print Mark Contrast Sensor, 800mm Detection Range, Red Laser, Laser Level 2, Light/Dark On, Sensitivity Adjuster, NPN Output, PNP Output, M12 Plug, Laser Print Mark Contrast Sensor, For Recording Very Small Print Marks, Laser, etc.
|
|
P+F/Capacitive Proximity Sensor CBN15-F64-E2 15mm
Introduction: Capacitive sensors can be used to detect targets in almost any material, including metal. These sensors are used in a wide range of applications for level and flow control, mainly liquids, particles and powders.
...
|
|
P+F capacitive sensor CJ40-FP-A2-P1 is non-flush mounted
Introduction: P+F capacitive sensor CJ40-FP-A2-P1 40 mm, non-flush; 4-wire DC; The switching distance can be set in a wide range by using a potentiometer. One terminal connector** can be fitted with up to two conductors with the same cross-sectional area of the core.
...
|
|
P+F/Through-beam photoelectric sensor LA39/LK39/31/40a/116
Introduction: P+F/Beijiafu through-beam photoelectric sensor LA39/LK39/31/40a/116 bright/dark on, switchable; Mounting accessories are available; The degree of protection is IP67. Inductive range adjuster, bright/dark switch.
Products...
|
|
P+F/Background Suppression Sensor MLV41-8-HV-60-IR-5360
Product Description: Visolux/ Pepperl+Fuchs has developed a range of special sensors for industrial use that extend the range of applications for common sensors. These special photoelectric sensors allow the customer to find a more suitable solution.
Specifications:
...
|
|
P+F/Retroreflective Area Sensor RLG28-55 / 115B / 136
Product Introduction: Retroreflective area sensor with 6 beams in a widely used standard photoelectric housing, red light, 4 m detection range, switchable bright/dark, push-pull output, M12 plug, reflective area sensor housing with 6 beams in a standard photoelectric sensor, connector and ...
|
|
P+F/Capacitive sensor NTK-H has a conductor cross-section of 0,34 mm2
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Pixel Fork Sensor GL5-J / 28A / 115 J design
Product introduction: Miniature photoelectric slot sensor is used to detect small parts, J-shaped design, fork width 5mm, infrared light, NPN output, fixed cable, miniature design, optimized for detecting small parts, high switching frequency, simple and quick installation, clearly visible LED function display.
...
|
|