Product Introduction: Switching sensors with measurement core technology have an enhanced range of functions. Based on the Multipixel Technology (MPT) developed by Pepperl + Fuchs, multiple operating modes and switching points can be easily set in a single triangulation sensor. These photosensors can be configured as background suppression sensors, background evaluation sensors, and window operation modes. With the standard IO-Link interface, switching sensors with measuring cores can be smoothly integrated into multifunctional applications.
Specifications:
Product Description | Measurement technology, 150 mm detection range, red light, IO-Link, 2 x push-pull outputs, 2 m fixed cable to switch the diffuse mode sensor |
General specifications | Detection range | 5 ... 150 mm | light source | LED | Light | Modulates visible red light | LED Risk Group Labels | Tax Exemption Group | Black/white difference (6%/90%) | <5% at 150mm | Spot diameter | About. 10 mm, distance 150 mm | Divergence angle | About. 4° | Functional safety-related parameters | MTTF d | 600 a | Task Time (TM) | 20 a | Diagnostic Coverage (DC) | 0% | Indicators/means of operation | Functional metrics | LED Yellow:
Continuous Lighting - Switching output
Persistent Disconnect - The switch output is invalid | Control elements | Teach the key | Electrical Specifications | Operating voltage | 10 ... 30 V DC | interface | Interface type | IO-Link (via C/Q = BK) | IO-Link revisions | 1.1 | Min. cycle | 2.3 ms | Processing of data | Process data input 2 bits
The process data output is 2 bits | Compatible primary port types | One | yield | Toggle the type | The default settings are:
C/Q - BK: NPN NP, PNP, IO-Link
Q2 - WH: NPN normally open, PNP normally closed | Signal output | 2 push-pull (4-in-1) outputs, short circuit protection, reverse polarity protection, overvoltage protection | Usage category | DC-12 and DC-13 | Compliance with standards and directives | Directive compliance | | | EMC Directive 2004/108/EC | EN 60947-5-2:2007 + A1:2012 | Standards Compliance | | | Product standards | EN 60947-5-2:2007 + A1:2012
IEC 60947-5-2:2007 + A1:2012 | Mechanical Specifications: | Ingress protection | IP67 / IP69 / IP69K | connect | 2 m fixed cable | material | | | housing | PC (Polycarbonate) | | Optical end faces | PMMA |
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
P+F photoelectric sensor M100/MV100-RT/35/76a/95/103
Description: The through-beam sensors are designed in a miniature design with a slit in the light of the miniature sensor, which is easy to use, very bright, with a high visible light point, full metal threaded mounting, and the high-efficiency series is mounted in a short M18 plastic housing for standard applications.
...
|
|
P+F Inductive Positioning System PMI120-F90-IU-IO-V15
Introduction:P+F Inductive Positioning System PMI120-F90-IU-IO-V15 Reverse Polarity Protection, Analog Current or Voltage Output, Programmable; Linearity ranges from 1 to 119 mm; PBT, stainless steel 1.4571, brass, nickel-plated housing.
...
|
|
P+F/Through-beam GD18 / GV18 /115/120
Product Introduction: Thru-beam sensor, M18 threaded housing design, plastic housing, front optical surface, 20 meters detection distance, red light, light and dark, DC version, 2 PNP outputs, fixed cable, high efficiency line, short M18 plastic housing application, very high detection range, 4 LED fingers...
|
|
The P+F/GIF sensor GLD3-RT /115/147 is programmable
Product Description: Visolux/ Pepperl+Fuchs has developed a range of special sensors for industrial use that extend the range of applications for common sensors. These special photoelectric sensors allow the customer to find a more suitable solution.
Specifications:
...
|
|
P+F/Capacitive sensor CBN5-F46-E2-10M 5mm
Introduction:P+F Capacitive Sensor CBN5-F46-E2-10M Flat Housing; reverse polarity protection; Fixing slot for cable tie, through-hole for screw mounting, cULus listed, general use.
Product parameters
...
|
|
P+F/Triangulation sensor OQT150-R100-2EP-IO 10-30VDC
Product Description: Measurement core technology, 150 mm detection range, red light, IO-Link, 2 x push-pull output, 2 m fixed cable, miniature design with multiple mounting options, Multipixel Technology (MPT) - Flexibility and adaptability, switching diffuse reflection mode sensors, reducing equipment ...
|
|
P+F inductive sensor NBN5-F7-E0 5 mm non-flush
Introduction: P+F inductive sensor NBN5-F7-E0 5 mm non-flush, switch function normally open (NO), output type NPN, rated working distance 5 mm, installation non-flush, output polarity DC, ensure operating distance 0 ... 4,05 mm
...
|
|
P+F/Capacitive sensor CBN15-F64-A2 15mm non-flush
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F inductive sensor NBB20-U1-Z2 flush 20 mm
Description: Inductive sensors are available in smooth or threaded stainless steel housings, reverse polarity protection and short-circuit protection, LED status indication, M8, M12 connector connection or terminal wiring, PVC, PUR or silicone cable outlet, 2-wire, 3-wire, 4-wire DC, AC, N...
|
|
P+F/Beam Ultrasonic Barrier UBEC300-18GH40-SE2-V1
Introduction: An ultrasonic through-beam sensor consists of a transmitter and a receiver mounted facing each other. Ultrasonic through-beam sensors work by emitting sound waves from the transmitter to the receiver to detect objects through the sound beam being interrupted by the target object. The emitter produces ultrasonic ...
|
|
P+F/Capacitive sensor CJ4-12GK-N 4mm non-flush
Introduction: Capacitive sensors can be used to detect targets in almost any material, including metal. These sensors are used in a wide range of applications for level and flow control, mainly liquids, particles and powders.
...
|
|
P+F Inductive Sensor NBN30-U1-E3 30mm non-flush
Introduction: Standard inductive sensor product features: smooth or threaded stainless steel cylindrical housing; reverse polarity protection and short circuit protection; LED status indicates M8, M12 connector connection or terminal wiring mode; PVC, PUR or silicon cable outlet; 2-wire, 3-wire, 4-wire DC, AC, ...
|
|
P+F/Double Sheet Sensor UDC-18GM-400-3E1-Y194142
Product Introduction: Ultrasonic double sheet detector is used to automatically and at high speed to distinguish substrate materials, labels, sheet-fed and double-fed, so as to protect the machine from waste in the production process. The whole system consists of an ultrasonic transmitter, an ultrasonic receiver and an external or built-in ...
|
|
P+F/Inductive sensor NBB20-L2-A2-V1 flush mounted
Introduction: Smooth or threaded stainless steel housing for inductive sensors; reverse polarity protection and short circuit protection; LED status indication; M8, M12 connector connection or terminal wiring; PVC, PUR or silicone cable outlet; 2-wire, 3-wire, 4-wire DC, AC, NAMUR and AS ...
|
|
P+F/Capacitive sensor CBN5-F46-E0-Y286690 distance 5mm
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/Capacitive sensor CJ30-50K10-E0123-Y46139 cable 2m
Introduction: The measurement of P+F/Capacitive sensors is usually one plate that makes up the capacitor, and the other plate is the housing of the switch. This housing is usually grounded or connected to the enclosure of the device during the measurement process. When an object moves towards a proximity switch, whether it is a conductor or not...
|
|
P+F/UB1000-18GM75-E5-V15
Product Introduction: The transducers used to transmit and receive sound waves are separated, so that the system does not need to wait for the signal attenuation of the transmitter, thus effectively reducing the dead zone. The direct detection type of ultrasonic sensors is available with switching and analog outputs. Direct detection of all support window mode functions ...
|
|
P+F/Inductive sensor NBN4-12GK50-E0/E2 voltage drop ≤3V
Introduction: Germany P+F/Beijiafu inductive sensor is the use of electromagnetic induction to measure physical quantities such as displacement, pressure, flow, vibration, etc. into the change of the self-inductance coefficient and mutual inductance coefficient of the coil, and then converted by the circuit into the output of voltage or current change, to achieve non-electric to electric ...
|
|
Germany P+F/Capacitive sensor CBB4-12GH60-E0-V1 with a voltage drop of ≤ 2,5 V
Description: Germany P+F/Capacitive sensor CBB4-12GH60-E0-V1 Voltage drop≤ 2,5 V, output type: PNP, reverse polarity protection: reverse polarity protection, no-load current: ≤ 12 mA
peculiarity
4 mm, flush
The working distance can be adjusted via a potentiometer
...
|
|
P+F/Background Suppression Sensor RL31-8-H-800-RT/73C/136
Product Description: Triangulation Sensor, Standard Application Background Suppression, Large Housing Design, 800 mm Adjustable Detection Range, Red Light, Low Light, Push-Pull Output, M12 Plug, Cost-Optimized Series for Standard Tasks, Small Housing Large Construction, High Visibility Indicator, Low Target Color ...
|
|