1. The arc is stable in the field of full current, the spatter is small, and the same welding machine is not only suitable for small current base welding, but also suitable for high current and high deposition rate work
2. Arc concentration and strong penetration. With the same penetration depth, the heat input is reduced by more than 20% compared to other gas shielded welding machines, and the heat distortion is extremely small
3. Strong gap bridging ability, insensitive dry elongation, suitable for all positions and novice welding
4. The microscopic technology of droplet necking detection and control is adopted, and the output is quickly cut off after the transition of the last drop of molten droplet, and there is no ball at the root of the welding wire, which greatly reduces the workload of the shear wire ball with high requirements for arc starting, and the success rate of one-time arc starting is extremely high, which improves the operation efficiency
5. There is no need to purchase any configuration, and the welding parameter password lock, various process parameters and expansion functions can be quickly set directly on the welding machine panel
6. The factory has 10 sets of welding parameters by default storage and calling function (up to 99 groups can be customized)
7. This series can be equipped with technical parameters for opening and robot communication connection
|
More on that
|
Megmeet inverter - maintenance precautions and items for high-voltage inverters
Precautions for maintenance of high-voltage inverters
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately
2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. Phase-shifting transformers ...
|
|
Megmeet welding machine - Classification and difference of laser spot welding machine
Laser spot welding machine, also known as resistance welding machine, is usually divided into three categories according to the nature of the welding power source: 1. AC spot welding machine; 2. Energy storage spot welding machine; 3. DC spot welding machine.
1. AC spot welding machine
Precision AC spot welding machine generally refers to the spot welding machine with a power of less than 16KVA.
|
|
Megmeet PLC - Comparison of the advantages of PLC and DDC in building automation systems
1. Application field: The initial design goal of PLC is only to replace complex relay circuits, and DDC is originally only used in industrial automation instruments: PLC emphasizes versatility, DDC emphasizes specificity: PLC is used in the field of industrial control, and DDC is used in professional building systems.
2. Structural differences ...
|
|
Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition
From April 13 to 16, 2021, CHINAPLAS 2021 was grandly held at the Shenzhen World Convention and Exhibition Center (Bao'an New Hall) with the theme of "New Era· New Power, · Sustainable Innovation".
As a vane of rubber and plastics professions and a barometer of shopping malls, the World Rubber and Plastics Exhibition has a 350,000 square meter ...
|
|
Common faults and solutions of Megmeet inverter
1. Leakage protection switch
Phenomenon: The leakage protection switch of the equipment is activated when the inverter is powered on or running
Measures:
When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be 150mA and above, and the action delay is ...
|
|
Megmeet drives – what are the basic requirements for regular replacement of drive components?
1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...
|
|
Megmeet inverters – Routine maintenance of high-voltage inverters requires precautions
1. The operating ambient temperature of the inverter (mainly refers to the air temperature of the air inlet of the power unit cabinet) requires a minimum ambient temperature of -5 °C and a maximum ambient temperature of 40 °C. In order to improve the reliability and extend the service life of the drive, check the following items:
Air conditioning and refrigeration ...
|
|
Megmeet drives – a common fault in low-voltage drives
External electromagnetic interference can easily cause malfunctions
If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...
|
|
Megmeet drives – routine and regular maintenance of drives
1. Maintenance items and scope:
Daily maintenance and maintenance of inverter
Due to the influence of environmental temperature, humidity, dust and vibration, it will lead to the aging of the internal components of the inverter, resulting in the potential failure of the inverter or reducing the service life of the inverter. Therefore, there is a must ...
|
|
Megmeet MC100 series plc – the right hand man in refrigeration equipment
First, the process requirements
When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time.
The high pressure collected is greater than that on the high pressure ...
|
|
Analysis of the fault code of Megmeet welder
1. E1: indicates sensor failure. In this case, it is necessary to check whether the sensors of Megmeet are damaged or whether the wiring is loose.
2. E2: Indicates overweight load. At this point, it is necessary to check whether the load of Megmeet exceeds the set maximum load.
3. E3: Indicates battery ...
|
|
Megmeet inverters – seven areas of application for high-voltage inverters
1. Metallurgical industry - the application of high-voltage inverter in the metallurgical profession mainly includes plate and wire rod rolling mills, coilers, fans, slurry pumps, etc., with the primary intention of motor energy saving.
2. Electric power industry - China's power generation capacity ranks second in the world, second only to United States. The power profession is also changing.
|
|
The unified setting of the Megmeet welding machine and the parameter setting of the system
1. Unified setting of Megmeet welding machine
The so-called unification of welding means that the welding machine automatically matches the welding voltage according to the currently set welding current and the unification voltage correction value.
The unification setting of Megmeet welder should first turn on the function on the welder side, ...
|
|
Common faults of Megmeet drives and how to deal with them
1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read
Cause: The current monitoring output is not blocked from the AC power supply (transformer).
Solution: You can use a DC voltmeter to detect and investigate.
2. Servo motor high speed ...
|
|
Megmeet welding machine - the application and precautions for the use of butt welding machine
The butt welding machine should be settled indoors, and should have a reliable grounding or zero connection, when a plurality of butt welding machines are connected to each other, the distance from each other shall not be less than 3m, and they should be connected to different corresponding power grids, and should have their own knife switches.
Before welding, the pressure of the butt welder should be checked and determined.
|
|
Megmeet PLC maintenance and processing methods
1. CPU abnormality: When the CPU is abnormally alarmed, check the device connected to the internal line of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...
|
|
Megmeet PLC – the three basic process contents of PLC work
1. Input processing
Input processing is also called input sampling. In this phase, the through-end state of all input terminals is read sequentially, and the read information is stored in the corresponding image register in memory. Here the input image register is flushed. Then the program execution phase begins. In the execution of the procedure ...
|
|
Megmeet PLC - the hardware composition of PLC control
1. Power components
The power supply assembly is used to provide the power required for the operation of the PLC, and the external power supply can be converted into a power supply for the PLC internal and applicable to the case.
2. Microprocessor CPU and memory components
Microprocessor CPU is the core device of PLC, and CPU is different from each manufacturer.
|
|
Megmeet PLC common faults
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
Megmeet PLC – three connection methods for PLC and frequency converter
1. Use the analog output module of the PLC to control the inverterThe analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but requires the option to ...
|
|