Megmeet PLC – the three output types of PLC

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

The first is relay output, the relay output response speed is slow, the output current is large, generally can reach 2A, but the electric shock life is short, the output frequency is low, the maximum is 1HZ;

The second is transistor output, the transistor output response speed is fast, the output current is small, the contact life is long, and the output frequency is very high, which can reach 10KHZ;

The third is analog output, which is generally 0--20MA current signal, 4--20MA current signal, 0--5V voltage signal, 0--10V voltage signal, etc.
Megmeet PLC – the three output types of PLC

More on that
Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use Megmeet new energy vehicle PEU intelligent manufacturing production line was put into use

Zhuzhou Lihui Technology Co., Ltd., a subsidiary of Megmit, has put into use a new production line of PEU intelligent production of new energy cars, leading the wave of intelligent production of PEU in the key "three electric" components of domestic new energy cars. Zhuzhou Lihui Technology Co., Ltd. production workshop, a new ...

Megmeet Inverter - Precautions for the Use of Inverter (11-21) Megmeet Inverter - Precautions for the Use of Inverter (11-21)

11. For the occasion when the inverter drives the ordinary motor for constant torque operation, long-term low-speed operation should be avoided as much as possible, otherwise the heat dissipation effect of the motor will become worse and the heating will be serious. If long-term operation at low speed constant torque is required, a variable frequency motor must be selected. 12. For the promotion of negative ...

Welding methods for Megmeet hand arc welding and MIG/MAG welding Welding methods for Megmeet hand arc welding and MIG/MAG welding

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.

Megmeet PLC – Analysis of common failures of PLC Megmeet PLC – Analysis of common failures of PLC

1. The CPU is abnormal When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the potentially problematic units sequentially, find out the problematic units, and deal with them accordingly. Second, the memory is abnormal Memory anomaly alarm ...

Megmeet PLC – the three basic process contents of PLC work Megmeet PLC – the three basic process contents of PLC work

1. Input processing Input processing is also called input sampling. In this phase, the through-end state of all input terminals is read sequentially, and the read information is stored in the corresponding image register in memory. Here the input image register is flushed. Then the program execution phase begins. In the execution of the procedure ...

Megmeet PLC - What is the difference between PLC and servo control system Megmeet PLC - What is the difference between PLC and servo control system

1. The meaning of the representation is different: PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane. A servo control system is a feedback control system used to accurately follow or reproduce a certain process.

The causes of the failure of the Megmeet welding machine and how to deal with it The causes of the failure of the Megmeet welding machine and how to deal with it

1. The welding machine has no welding current output 1. Cause of failure: the internal wiring of the non-voltage input at the input end of the welding machine falls off or the internal coil of the broken circuit is burned out. 2. Treatment method: check whether the switch, wire, fuse and connection parts from the distribution box to the input end of the welding machine are in good condition.

Megmeet inverter mv600 alarm code ENOC2 Megmeet inverter mv600 alarm code ENOC2

1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time. 2. Avoid rapid increase in load. 3. Check whether there is a short circuit in the UVW of the motor terminal. 4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm. ...

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20)

11。 If the interface board does not communicate with the monitor and does not establish communication with the interface board, the interface board will reset the monitor every 5 seconds, and if the communication is not established within 3 minutes and 30 seconds, it will be judged as a serious fault. Whether the communication line is normal, check whether the terminal is correct; Whether the I/O board is working properly. Especially the work ...

Megmeet drive common fault repair methods Megmeet drive common fault repair methods

When the oscilloscope looks at the current monitoring output of the driver, it is all noisy and cannot be read Cause: The current monitoring output is not blocked from the AC power supply (transformer). Solution: You can use a DC voltmeter to detect and investigate. Servo motor high-speed rotation ...

Analysis of the fault code of Megmeet welder Analysis of the fault code of Megmeet welder

1. E1: indicates sensor failure. In this case, it is necessary to check whether the sensors of Megmeet are damaged or whether the wiring is loose. 2. E2: Indicates overweight load. At this point, it is necessary to check whether the load of Megmeet exceeds the set maximum load. 3. E3: Indicates battery ...

Megmeet PLC – three connection methods for PLC and frequency converter Megmeet PLC – three connection methods for PLC and frequency converter

1. Use the analog output module of the PLC to control the inverterThe analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but requires the option to ...

What are the characteristics of Megmeet PLC - PLC working process? What are the characteristics of Megmeet PLC - PLC working process?

(1) The PLC adopts the working mode of centralized sampling and centralized output, which reduces the influence of external interference. (2) The working process of PLC is the process of cyclic scanning, and the length of cyclic scanning time depends on the speed of instruction execution, the length of the user program and other factors. (3) Output ...

Megmeet inverter - maintenance precautions and items for high-voltage inverters Megmeet inverter - maintenance precautions and items for high-voltage inverters

Precautions for maintenance of high-voltage inverters 1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. Phase-shifting transformers ...

Megmeet PLC - What is the difference between PLC and MCU? Megmeet PLC - What is the difference between PLC and MCU?

1. PLC is a relatively mature control system composed of single-chip microcomputer, which is the product of a mature and stable single-chip microcomputer application system that has been debugged. It is highly versatile. 2. The single-chip microcomputer can form a variety of application systems, and the application range is wider. In the case of a single "microcontroller", it ...

Solutions to common faults of Megmeet inverter (2) Solutions to common faults of Megmeet inverter (2)

Fault three Fault phenomenon: There is a rebound phenomenon when the rotation starts Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5) 2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet drives – what are the basic requirements for regular replacement of drive components? Megmeet drives – what are the basic requirements for regular replacement of drive components?

1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...

Megmeet inverter – the difference between voltage type inverter and current type inverter Megmeet inverter – the difference between voltage type inverter and current type inverter

1. The load of the buffer inverter without functional quantity is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Since the power electronic switching devices cannot be stored for energy, the non-functional energy can only rely on the energy storage elements (filters).

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top