Fisher Fisher Control Valve Selection Parameter Requirements

Create Date: 2024-8-30 12:03:23|Source: Fisher

1. Medium (medium state, medium density, medium viscosity)?

2. Pressure range (design pressure?) Pre-valve pressure? After-valve pressure? Large differential pressure? Critical pressure? Saturated vapor pressure? )

3. Flow rate (*** small?) Normal? Big? )

4. Temperature?

5. What is the form of the executive agency?

6. Where does it fail?

7. Is there a handwheel?

8. How to connect?

9. Is a solenoid valve needed? What are the requirements for flameproof rating?

10. What are the requirements for limit switches?

11. Locator?

12. With feedback?

13. Air pressure?

14. What is the size of the pipe? Pipe material? Pipe pressure rating?

15. What is the valve number?

To sum up, the customer fills in according to the working conditions, as detailed as possible, some items that are not available or do not understand the items can not be filled, according to the actual working conditions, the engineer may need to add and ask for other parameters.
Fisher Fisher Control Valve Selection Parameter Requirements

More on that
Fisher Fisher - Valve Positioner Steps to get the correct valve diagnostic analysis data Fisher Fisher - Valve Positioner Steps to get the correct valve diagnostic analysis data

What should I pay attention to when the automatic initialization of the valve positioner is unsuccessful? DVC6200 smart valve positioners need to be initialized before they are put into use, and due to incorrect installation and use, they often run into trouble during the initialization process. place There are several aspects that need to be noted: 1 ...

Fisher Fisher—Why cryogenic valves use long neck bonnets Fisher Fisher—Why cryogenic valves use long neck bonnets

Valves suitable for medium temperature -40 °C ——- 196 °C are called cryogenic valves, and such valves generally use long neck bonnets. Adopt a long neck valve

Fisher Fisher - On the issue of not having a SIS on the production unit or storage tank farm Fisher Fisher - On the issue of not having a SIS on the production unit or storage tank farm

On the issue of not having SIS on the production plant or storage tank farm, share your opinions: First of all, we have to figure out what SIS is for, in fact, SIS is not as mysterious as imagined, its function is the same as safety valves, rupture discs, etc., is a safe protective layer. That...

Fisher Fisher-Fisher Valve Positioner DVC6200 3 points to pay attention to when using it Fisher Fisher-Fisher Valve Positioner DVC6200 3 points to pay attention to when using it

Fisher Fisher Valve Positioners are compressed air-actuated valves that can be used to control the flow of liquids, oils, slurry metals, radioactive media, and various types of fluids such as water, steam, air, and various corrosive media. Then the following editor will introduce you to the Fisher valve ...

Fisher Fisher - Solenoid valves for different media options Fisher Fisher - Solenoid valves for different media options

Solenoid valves are selected for different media 1. Corrosive medium: it is advisable to choose plastic king solenoid valve, all stainless steel solenoid valve; For the strong corrosive medium must be selected isolation diaphragm type, such as: neutral medium, it is also advisable to choose copper alloy as the solenoid valve housing material, otherwise, there are often rust chips falling off in the valve housing.

How does a valve positioner work? Locator failures and solutions How does a valve positioner work? Locator failures and solutions

There are intelligent positioners and mechanical positioners for valve positioners, and today we are talking about the latter mechanical positioner, which is the same as the positioner shown in the picture Schematic diagram of valve positioner structure In the figure, the components of the mechanical pneumatic valve positioner are basically explained one by one, and the next thing is to look at it.

Fisher Fisher-Cavitation Valve Trim helps improve plant availability and safety. Fisher Fisher-Cavitation Valve Trim helps improve plant availability and safety.

Emerson's Fisher ™ Kaft Hex Valve Strict working valve trimming reduces or eliminates cavitation to improve rotary valve performance and extend service life. The Fisher Vee-Ball Rotary™ Control Valve is now available with the Cavertro ™ Hex Valve Anti-Cavitation Trim to reduce or eliminate the effects of cavitation.

Fisher - Control and classification of Fisher controllers Fisher - Control and classification of Fisher controllers

When the Fisher controller is in use, we need to understand the classification of the controller and the control method of the controller. Through an in-depth understanding of the controller, we will be more proficient and convenient in use. Then the editor below will introduce these two aspects for us. Fisher Controller's ...

Fisher Fisher 3582i and 582i classification and differences Fisher Fisher 3582i and 582i classification and differences

Fisher Fisher 3582-Pneumatic Valve Positioner with Bypass, with Input Signal, Air Supply and Output Pressure Gauges Series Contains: Model 3582A, Model 3582C, Model 3582D, Model 3582G, unless otherwise stated and 3582NS. Type 3582A - Pneumatic valve positioner without bypass ...

What are the conditions that need to be paid attention to when choosing a FISHER regulator in United States? What are the conditions that need to be paid attention to when choosing a FISHER regulator in United States?

United States FISHER gas equipment has first-class quality and advanced technology, which is the technical vane of the gas equipment industry. It provides high-quality products and technologies, consulting, project management and maintenance services for specific gas equipment industries. FISHER is a Fortune 500 company in the world.

Fisher Flow Amplifier ASCO 614 Series Solutions Fisher Flow Amplifier ASCO 614 Series Solutions

The Fisher/fisher ASCO Series 614 SentronicPlus is a digitally operated, three-way proportional regulator. Adjustable pressure, flow, force, speed, and linear or angular position. Air and inert gas media can be controlled. According to the ATEX Directive 2014/34/EU, its structure ...

Fisher Fisher - Pressure testing methods for various valves Fisher Fisher - Pressure testing methods for various valves

Pressure testing method for ball valves The strength test of the pneumatic ball valve should be carried out in the semi-open state of the ball. (1) Floating ball valve tightness test: the valve is in a half-open state, one end is introduced into the test medium, and the other end is closed; Turn the ball several times, open the closed end inspection when the valve is closed ...

Fisher - Valve installation, maintenance, and operation Fisher - Valve installation, maintenance, and operation

To extend the life of a Fisher valve, most of us pay attention to installation and maintenance, but operation is also important. For valves, it is necessary to be able not only to install and maintain, but also to operate. Dongguang valve pointed out: valve installation, maintenance, operation, no one is missing...

Fisher Fisher-1098EGR and 1098H-EGR Decompression Regulators Fisher Fisher-1098EGR and 1098H-EGR Decompression Regulators

The Fisher Model 1098-EGR and 1098H-EGR regulators provide economical and accurate pressure control in a variety of applications; natural gas distribution systems; gas supply for industrial boilers, furnaces, ovens and mixers; and large commercial/industrial establishments such as shopping malls and schools. They are also used in industrial ...

Fisher Fisher - Why do control valves vibrate? Cause analysis Fisher Fisher - Why do control valves vibrate? Cause analysis

The vibration of the control valve is generally divided into two states, one is the overall vibration of the control valve, that is, the entire control valve frequently vibrates on the pipeline or base. The other is the vibration of the spool of the regulating valve, which can be seen from the frequent movement of the valve stem up and down, and the following are the causes of these two vibrations and their treatment Measure...

FISHER DVC2000/DVC6200 Smart Valve Valve Positioner Calibration FISHER DVC2000/DVC6200 Smart Valve Valve Positioner Calibration

FISHER Valve Positioner From mechanical to intelligent, FISHER Intelligent Valve Positioner can effectively reduce the labor intensity of maintenance personnel in the first line. Intelligent communication mode: The obvious feature of intelligent valve positioner is intelligent communication. For our process industry ...

Fisher Fisher - How Do Electrical Valve Positioners Maintain a Steady State? Fisher Fisher - How Do Electrical Valve Positioners Maintain a Steady State?

When the electrical valve positioner is used, we need to understand its operating principle, and after understanding, install and use it according to the principle, so as to obtain accurate data. Then the editor below will introduce you to the relevant knowledge of valve positioner. The principle of action of the electrical valve positioner ...

Understanding flash in control valves and how to minimize metal corrosion damage? Understanding flash in control valves and how to minimize metal corrosion damage?

The Fisher FISHER control valve reduces maintenance costs, minimizing the effects of metal corrosion damage due to water spray. Learn about flash evaporation in control valves Flickering occurs when a liquid flows through a control valve and evaporates and retains the vapor. Scintillation with choke flow and cavitation have ...

Fisher-Emerson launches the PACMotion servo motion control product family Fisher-Emerson launches the PACMotion servo motion control product family

Emerson announces the launch of its new PACMotion servo motion control product family, providing integrated automation solutions for high-performance industrial applications. The series includes a new motion controller that connects directly to the PACSystemsRX3i programmable logic controller backplane, ...

Fisher - Fisher's FAQs Fisher - Fisher's FAQs

In the use of Fisher Valve Positioner Control Valve, we may encounter some different situations, such as: positioner signal conditioner force instability, pneumatic valve source regulator force instability, positioner without pneumatic valve, etc., the following editors will introduce these situations. Fisher Fisher ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top