Fisher Fisher - Solenoid valves for different media options

Create Date: 2024-8-30 12:03:23|Source: Fisher

Solenoid valves are selected for different media

1. Corrosive medium: it is advisable to choose plastic king solenoid valve, all stainless steel solenoid valve; For the strong corrosive medium, the isolation diaphragm type must be selected, such as: neutral medium, it is also advisable to choose the solenoid valve with copper alloy as the valve housing material, otherwise, the rust chips often fall off in the valve housing, especially when the action is infrequent. Ammonia valves cannot be made of copper. For wine making and milk process pipelines, food-grade stainless steel solenoid valves should be used.

2. High temperature medium: the temperature of the medium should be selected within the allowable range of the solenoid valve. For example, hot water, steam, and heat conduction oil should choose the varieties of high-temperature resistant electromagnetic coils and sealing materials, and the piston structure type should be selected. For example, the steam should be made of stainless steel or series, and the copper material is not good at this time, because when the temperature exceeds the expansion coefficient of copper, it contradicts the tolerance between the piston parts of the solenoid valve and the piston cavity, resulting in ineffective operation.

3. Medium state: large to gaseous, liquid or mixed state, different varieties of solenoid valves should be selected, that is, for gas or different medium for liquid, and the medium form should be indicated, otherwise it is not conducive to the stability of the valve's performance.

4. Medium viscosity: usually in the following can be arbitrarily selected, if it exceeds this value, it is necessary to choose a high-viscosity solenoid valve.

5. Cleanliness of the medium: If the medium contains a small amount of small impurities, the diaphragm structure can be selected, but if the impurities are large and more, the filter should be installed in front of the solenoid valve. Understand what we need, in order to choose our most suitable solenoid valve
Fisher Fisher - Solenoid valves for different media options

More on that
Fisher Fisher - Seven routine maintenance tasks for control valves Fisher Fisher - Seven routine maintenance tasks for control valves

Routine maintenance is a planned overhaul before a control valve fails, which can be understood as preventive maintenance and usually includes the following tasks. 1. Stress relief Pipelines can produce various stresses due to improper combination or installation, such as thermal stress caused by high-temperature media, uneven tightening force during installation, etc.

Fisher Fisher - 6 Packing Material Selection Methods for Valve Stem Seals Fisher Fisher - 6 Packing Material Selection Methods for Valve Stem Seals

When choosing a valve stem packing, it should be determined according to the specific conditions. The method we generally choose is: between pressure and temperature, only one *** value can be satisfied; When choosing a high-temperature valve packing, the temperature should be considered first; For corrosive media with low temperature and pressure, the ...

Fisher Fisher - Teaches you how to improve the life of your valves Fisher Fisher - Teaches you how to improve the life of your valves

In the valve design or use experience, the lifting valve packing is mostly asbestos packing or graphite packing or PTFE V-type packing, but these packings are limited by the number of valve opening and closing, that is, with the increase of the number of valve opening and closing, the packing will wear out, and the gap will gradually increase, to a certain number of times.

United States Fisher pneumatic valve positioner fault repair and protection methods United States Fisher pneumatic valve positioner fault repair and protection methods

United States Fisher Pneumatic Valve Positioner is the primary accessory to the Pneumatic Control Valve, which is a single-output valve positioner. It describes the main features and common faults of the valve positioner, as well as the treatment methods and protection methods. 1. The main features of the locator (1) Large-diameter pilot ...

Fisher positioners in the pulp and paper industry Fisher positioners in the pulp and paper industry

FISHER Locator is a division of Emerson Electric Company, a Fortune 500 United States. In 1992, Emerson acquired Fisher and merged with Rosemount, another world leader in process instrumentation, to form Fisher-Rosemount to better ...

Fisher - Valve installation, maintenance, and operation Fisher - Valve installation, maintenance, and operation

To extend the life of a Fisher valve, most of us pay attention to installation and maintenance, but operation is also important. For valves, it is necessary to be able not only to install and maintain, but also to operate. Dongguang valve pointed out: valve installation, maintenance, operation, no one is missing...

Fisher Fisher - Fisher valve rust removal method Fisher Fisher - Fisher valve rust removal method

(1) The commonly used rust removal methods are divided into the following five points A common method for removing rust on surfaces of various finishes Kind: Metal surface finish is commonly used as a rust removal method 1. Use grinding wheels, wire brushes, scrapers, and gauze to pickle and remove rust 21-4 Dip machine with non-metallic scraper, oil stone or gauze with particle size 150 ...

Fisher Fisher - What Industries Need Valves? Fisher Fisher - What Industries Need Valves?

Fisher valve application types In terms of the types of application valves, there are many types of valves used in machinery, metallurgy, petrochemical, chemical industry, urban construction and other industries. Especially in the machinery industry, all kinds of valves are basically used. In addition to the machinery industry, safety valves are mainly used in the chemical industry; Butterfly valves should be ...

Fisher Fisher - Why do control valves vibrate? Cause analysis Fisher Fisher - Why do control valves vibrate? Cause analysis

The vibration of the control valve is generally divided into two states, one is the overall vibration of the control valve, that is, the entire control valve frequently vibrates on the pipeline or base. The other is the vibration of the spool of the regulating valve, which can be seen from the frequent movement of the valve stem up and down, and the following are the causes of these two vibrations and their treatment Measure...

Fisher Fisher - What are the precautions for the use of pneumatic control valves Fisher Fisher - What are the precautions for the use of pneumatic control valves

The pneumatic control valve is to use compressed air as the power source, the cylinder as the actuator, and with the help of electrical valve positioners, converters, solenoid valves, position retention valves and other accessories to drive the valve, realize the switching or proportional adjustment, and receive the control signal of the industrial automation control system to complete the adjustment.

Fisher Fisher 627, 627R, 627LR, 627M regulators Fisher Fisher 627, 627R, 627LR, 627M regulators

The Fisher Fisher Models 627R and 627MR are equipped with a stroke stop—an internal pressure relief valve that works even if the disc or linkage fails. When the valve diaphragm is rising, the push rod touches the stroke stop on the lever retainer, and as the valve diaphragm continues to rise, the pressure relief valve is beaten.

Fisher pressure regulator, fisher 299H pressure regulator valve in large quantities, Fisher 299H in the field of industrial control applications Fisher pressure regulator, fisher 299H pressure regulator valve in large quantities, Fisher 299H in the field of industrial control applications

The Fisher Series 299H Regulator is a pilot regulator with VSX2 type, which provides customers with controllable regulation of pressure and flow, mainly used in branch and commercial portals of industrial conveying and LNG regulator skids. The product has been verified and improved by the market for a long time, and has been fully tested to f...

Fisher Fisher - Fisher 3610JP Pneumatic Double Acting Positioner Fisher Fisher - Fisher 3610JP Pneumatic Double Acting Positioner

The Fisher 3610JP pneumatic positioner is used in conjunction with a double-acting rotary actuator to position control valves for throttling applications. These rugged positioners provide valve position proportional to the pneumatic or DC current input signal and are mounted integrally to the actuator housing. specification ...

Fisher – Fisher – Valve positioner hardware system design Fisher – Fisher – Valve positioner hardware system design

The system hardware design of the valve positioner needs to reduce the interference between the analog ground and the digital ground, and at the same time make full use of the internal space of the positioner housing to divide the hardware system into two parts: the main control board and the interface board. Among them, the main control board of the valve positioner includes a single-chip microcomputer Z small system and a human-computer interaction model.

Emerson introduces the Fisher L2e level controller Emerson introduces the Fisher L2e level controller

Emerson has introduced the Fisher L2e Level Controller, which provides comprehensive electric level control for a wide range of applications in production and process systems. The new Emerson Fisher L2e controller uses a force-balanced displacement sensor to detect the level of a single liquid or two...

Fisher Fisher - Seven common problem solutions for pneumatic butterfly valves Fisher Fisher - Seven common problem solutions for pneumatic butterfly valves

Seven common problem solutions for pneumatic butterfly valves: 1. The butterfly valve is installed in the pipeline, and the best position is vertical, but it cannot be reversed. 2. It is recommended to use the special flange of the butterfly valve, that is, the HGJ54-91 socket welded steel flange. 3. Butterfly valve stem installation ...

Fisher control valves Fisher control valves

Fisher control valves are divided into electric control valves, pneumatic control valves and manual control valves, and the following mainly introduces pneumatic control valves and electric control valves. Fisher pneumatic control valve is based on compressed air as the power source, cylinder as the actuator, and with the help of electric/pneumatic valve positioner, converter, ...

Fisher Fisher - Why do steam pipes often have to be bent a section? Fisher Fisher - Why do steam pipes often have to be bent a section?

We often see such a scene on the steam pipeline, the pipe section that can be "straight" suddenly bent a section, I believe that many people who have seen it will have such doubts like me, this is not "painting snakes", in fact, the design of the pipeline operation has its own original...

Fisher Fisher - Gas Pressure Reducing Valve Operating Principle and Selection Criteria Fisher Fisher - Gas Pressure Reducing Valve Operating Principle and Selection Criteria

The gas pressure reducing valve is to control the opening of the opening and closing parts in the valve body to adjust the flow of the medium, reduce the pressure of the medium, and at the same time adjust the opening of the opening and closing parts with the help of the pressure behind the valve, so that the pressure behind the valve is kept within a certain range, and the cooling water is sprayed in the valve body or behind the valve to reduce the pressure of the medium.

Fisher Fisher - Butterfly Valve Test & Installation & Troubleshooting Fisher Fisher - Butterfly Valve Test & Installation & Troubleshooting

1. Testing and adjustment 1. Whether it is manual, pneumatic, hydraulic or electric, all parts of this product have been seriously debugged before leaving the factory, and the user should uniformly fix both ends of the import and export when re-checking the sealing function Fixed, close the disc valve, apply pressure to the inlet side, and check whether there is any leakage on the outlet side, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top