Megmeet drive common fault repair methods

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

When the oscilloscope looks at the current monitoring output of the driver, it is all noisy and cannot be read

Cause: The current monitoring output is not blocked from the AC power supply (transformer).

Solution: You can use a DC voltmeter to detect and investigate.

When the servo motor rotates at high speed, the motor error counter overflows the error, how to deal with it?

Reason 1: When rotating at high speed, the motor error counter overflows to fault;

Solution: Check whether the wiring of the motor power cable and encoder cable is correct, and whether the cable is damaged.

Reason 2: When inputting a long instruction pulse, the motor error counter overflows the error;

Solution:

a. If the gain setting is too large, adjust the gain manually from scratch or use the active adjustment gain function;

b. Extend acceleration and deceleration time;

c. The load is too heavy, and it is necessary to select a motor with a larger capacity or reduce the load from scratch, and install a reducer and other transmission organizations to improve the load.

Reason 3: During operation, the motor error counter overflowed to fault.

Solution:

a. Increase the error counter overflow level set value;

b. Slow down the rotation;

c. Extend the acceleration and deceleration time;

d. The load is too heavy, and it is necessary to select a motor with a larger capacity or reduce the load from scratch, and install a reducer and other transmission organizations to improve the load.
Megmeet drive common fault repair methods




More on that
Megmeet inverter - introduction to the control method of low-voltage inverter Megmeet inverter - introduction to the control method of low-voltage inverter

1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of the industry. However, this control ...

Megmeet PLC – The importance of PLC industrial gateways Megmeet PLC – The importance of PLC industrial gateways

1. Realize remote control of industrial field equipment; 2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms; 3. Realize remote control of industrial site touch screen and remote mapping of configuration screens; 4. PLC industry ...

Megmeet inverter – the basic principle and application of high-voltage inverter Megmeet inverter – the basic principle and application of high-voltage inverter

The basic principle of a high-voltage inverter There are two categories of frequency conversion process of frequency converter: AC-AC form and AC-DC-AC form. Now it is mostly in the form of AC-DC-AC, and the following is a brief introduction to the working principle of this form. Three-phase high-voltage electricity enters the high...

Megmeet inverter – the energy-saving principle of low-voltage inverter Megmeet inverter – the energy-saving principle of low-voltage inverter

Inverter energy saving The energy saving of the inverter is mainly manifested in the application of fans and pumps. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus. When the motor cannot operate at full load, in addition to meeting the power drive requirements, ...

Maintenance method of Megmeet PLC Maintenance method of Megmeet PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet MC100 series plc – the right hand man in refrigeration equipment Megmeet MC100 series plc – the right hand man in refrigeration equipment

First, the process requirements When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time. The high pressure collected is greater than that on the high pressure ...

Megmeet PLC - PLC's inverter control motor forward and reverse wiring diagram Megmeet PLC - PLC's inverter control motor forward and reverse wiring diagram

1. After connecting the wires according to the wiring diagram, start the power supply and prepare to set the parameters of the inverter. 2. Press the "MODE" button to enter the parameter setting mode, and set the Pr.79 to "2": external operation mode, the start signal is input by the external terminal (STF, STR), and the speed adjustment is carried out by the external terminal.

Megmeet drives – a common fault in low-voltage drives Megmeet drives – a common fault in low-voltage drives

External electromagnetic interference can easily cause malfunctions If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...

New Arrivals! Hollysys' two blockbuster products were unveiled at the Zhongguancun Forum Technology Trading Conference New Arrivals! Hollysys' two blockbuster products were unveiled at the Zhongguancun Forum Technology Trading Conference

On September 24, the 2021 Zhongguancun Forum, co-sponsored by the Ministry of Science and Technology of China, the Chinese Academy of Sciences, the China Association for Science and Technology, and the Beijing Municipal People's Government, officially opened in Beijing. As one of the main agendas of the forum, the Zhongguancun International Technology Exchange Conference closely follows the "smart· healthy· carbon neutrality...

Megmeet welding machines – the main application area of resistance welding Megmeet welding machines – the main application area of resistance welding

(1) Spot welding: The weldment is pressed between the two cylindrical electrodes, heated by electricity, so that the weldment melts at the contact to form a nugget, and then the power is cut off, and it solidifies and crystallizes under pressure to form a dense solder joint. Spot welding is suitable for welding thin plates (laps) and steel bars below 4 mm.

Megmeet inverters – seven areas of application for high-voltage inverters Megmeet inverters – seven areas of application for high-voltage inverters

1. Metallurgical industry - the application of high-voltage inverter in the metallurgical profession mainly includes plate and wire rod rolling mills, coilers, fans, slurry pumps, etc., with the primary intention of motor energy saving. 2. Electric power industry - China's power generation capacity ranks second in the world, second only to United States. The power profession is also changing.

Megmeet PLC - What are the features of the PLC program? Megmeet PLC - What are the features of the PLC program?

1. Correctness (low debugging cost) First of all, the PLC program must be able to work correctly to meet the requirements of the actual control process. This is the essence of the PLC program, and if you don't do that, nothing else makes sense. 2. Reliability (low maintenance cost) Not only to ...

Megmeet inverter - what are the control methods of the inverter? Megmeet inverter - what are the control methods of the inverter?

Sinusoidal Pulse Width Modulation (SPWM) control mode It is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of industry. However, this type of control is at low frequencies, ...

Megmeet inverter - the role and application of the inverter control cabinet introduction Megmeet inverter - the role and application of the inverter control cabinet introduction

Inverter control cabinet (inverter electrical control cabinet / electric control cabinet / electric control box) is an electrical control cabinet developed by using inverters from Siemens, ABB, Schneider, Fujifilm, Mitsubishi, Panasonic, Delta, Shilin, Inovance and other manufacturers. According to the needs of working conditions, AC transmission can be installed in the frequency conversion cabinet.

Megmeet inverters – what are the development directions of inverter-related technologies? Megmeet inverters – what are the development directions of inverter-related technologies?

1. Intelligent network The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the inverter complex in the factory.

Megmeet drives – safety precautions for the installation of drives Megmeet drives – safety precautions for the installation of drives

When the inverter is installed and wired; Note: When more than two inverters are installed in the same cabinet, please pay attention to the installation position and spacing to ensure the heat dissipation effect. Dangerous: 1. It should be operated by professional electrical engineering personnel, otherwise there is a risk of electric shock. 2. Please make sure before wiring...

Megmeet drives – the replacement steps for high-voltage drive power units Megmeet drives – the replacement steps for high-voltage drive power units

1) Shut down, so that the inverter out of the operating state; 2) Cut off the high-voltage power supply and push out the high-voltage cabinet trolley (when there is a bypass cabinet. The inverter can be isolated by the disconnecting switch of the bypass cabinet), the local or remote high-voltage disconnect switch can be locked, and the high-voltage cabinet grounding switch can be grounded; 3) Hit ...

Megmeet PLC - What is the difference between PLC and servo control system Megmeet PLC - What is the difference between PLC and servo control system

1. The meaning of the representation is different: PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane. A servo control system is a feedback control system used to accurately follow or reproduce a certain process.

Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition

From April 13 to 16, 2021, CHINAPLAS 2021 was grandly held at the Shenzhen World Convention and Exhibition Center (Bao'an New Hall) with the theme of "New Era· New Power, · Sustainable Innovation". As a vane of rubber and plastics professions and a barometer of shopping malls, the World Rubber and Plastics Exhibition has a 350,000 square meter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top