Quick steps to debug the inverter – Xinjie

Create Date: 2024-8-30 12:03:23|Source: XINJE

1. Check the full-load power supply of the inverter (Variable-frequency Drive (VFD).

1. Ground the terminal strip of the VFD.

2. Type the switching power supply of VFD into the terminal and receive it from the switching power supply through the power switch of the leakage protector.

3. Check whether the original flash information of the VFD flashing information window is all normal, assuming that there is a mistake, it should be calibrated, otherwise it will be returned.

4. Understand the practical operation keys of VFD. Generally, VFD has six keys, such as RUN, STOP, PROG, data message p, UP, ▲, DOWN, ", etc. At the same time, in practice, the key boundaries of different VFDs are the same. In addition, some VFDs have utility buttons such as monitor flashing, reset, jogging, and shifting.

                               Quick steps to debug the inverter – Xinjie

2. VFD with motor works at full load

1. Set the output power of the motor, which is very small, and think about the amount of current in the VFD operation inductively.

2. Set the VFD's maximum output frequency, fundamental frequency, and torque characteristics. General-purpose VFDs always have several VPf curves for customers to choose, and customers should select the appropriate VPf curves according to the characteristics of the load when applying. Assuming that the load of centrifugal fans and pumps is assumed, the torque working code of the VFD should be set to the variable torque and reduced torque working characteristics. In order to better improve the low-speed gear characteristics of VFD starting, so that the torque output by the motor can be used to consider the rules for consumer production load starting, the starting torque must be dispatched. In the multi-threaded motor DC frequency conversion system software, the control of torque is more complicated. At low frequencies, the damage caused by resistors and reactance cannot be ignored, but if VPf is kept as a parameter, the magnetic flux is reduced, and the output torque of the motor is reduced. Therefore, in the low frequency band, it is necessary to turn on the operating voltage to properly compensate for the torque improvement. Generally, VFD is set up by the customer's manpower.

3. Set VFD as the built-in computer keyboard to practice operation, press the work button and stop button to check whether the motor can start and stop normally.

4. Understand the protection code when common defects occur in VFD work, observe the original value of thermal protection car relay, observe the setting value of overvoltage protection, and change it if necessary. VFD application staff can turn on the settings of the VFD's electronic thermal relay effects according to the VFD's operating manual. When the output current of the VFD exceeds its promised current, the VFD's overcurrent protection will disconnect the output of the VFD. Therefore, the maximum threshold value of the thermal relay of the VFD electronic device does not exceed the maximum promised output current of the VFD.

Third, load test work

1. Manually operate the working stop button of the VFD control panel, observe the whole process of motor working stop and the flashing information window of VFD to see if there is any abnormal situation.

2. Assuming that the VFD has an overcurrent protection attitude during the whole process of starting P to stop the motor, the acceleration P deceleration time should be set again. The instantaneous speed of the motor in addition and gear change lies in the acceleration torque, and the frequency elasticity coefficient of VFD in the whole process of starting and braking system is set by the customer. Assuming that the inertia torque or load of the motor changes, and the speed increase or shift is stopped according to the preset frequency elasticity coefficient, there may be a lack of acceleration torque, which may cause the motor to flutter, that is, the motor speed ratio is not in harmony with the VFD output frequency, resulting in overcurrent or overvoltage. Therefore, it is necessary to effectively set the acceleration and deceleration times according to the motor moment of inertia and load, so that the frequency elasticity coefficient of VFD can be harmonious with the elastic coefficient of the motor speed ratio.

The way to check whether the setting is effective is to select the acceleration and deceleration time according to the work experience to open the setting, if there is an overcurrent during the whole process of starting, the acceleration time can be moderately increased; If there is an overcurrent during the whole process of the braking system, the deceleration time is moderately increased. On the other hand, the acceleration and deceleration time should not be set too long, and the time will damage the consumption rate, especially when the system is always started and braked.

3. Assuming that the VFD is still protected within the limited time, the working curve diagram of the start and stop should be changed from parallel line to S-shaped, and the U-shaped line should be S-shaped and inverse U-shaped. When the inertia force of the motor load is very large, a longer starting stop time should be selected, and the type of working curve should be set according to its load characteristics.

4. Assuming that VFD still has common shortcomings in work, we should try to increase the protection value of a larger current, but the protection cannot be canceled, and at least 10%-20% of the protection capacity should be reserved.

5. Assuming that the common shortcomings of VFD work still occur, the VFD with a larger output power should be replaced

6. Assuming that the VFD propulsion motor cannot reach the preset rate during the whole starting process, it is likely that there are two situations:

(1) The system software produces dynamic electrical engineering resonance, which can be distinguished from the sound of motor work.

By choosing the method of setting the frequency bounce value, it is possible to bypass the resonance point. Generally, VFDs can set three levels of bounce points. When VPf dominates the VFD driver multi-threaded motor, in some frequency bands, the current and speed ratio of the motor will vibrate, and the system software will not work when it is severe, and even in the whole process of acceleration, the current protection will promote the motor to not be able to start normally, and the motor load or moment of inertia will be more severe than the hour. Generally, VFDs always have a frequency jumping effect, and customers can set the jump point and the total width of the jump on the VPf curve graph according to the frequency point of vibration generated by the system software. When the motor accelerates, it can actively cross this frequency band to ensure that everything can work properly.

(2) The torque output ability of the motor is lacking, the original basic parameters of VFD of different well-known brands are not the same, and the load ability is not the same under the same standard, and it is also very likely that the load ability of the motor is not the same due to the different VFD control measures; Or due to the different output efficiency of the system software, there will be a certain difference in the load ability. In such cases, it is possible to increase the value of torque progression. Assuming that it cannot be reached, the effect can be improved by manual torque, and the temperature rise of the motor will increase without setting it too large. The assumption is still not good, and it should be changed to new control measures, such as the method of using a stable VPf ratio for Kobelco VFD, and the closed-loop control method for indoor space without a speed sensor when the starting is not up to the standard, which has a larger torque output ability. For centrifugal fans and pumps, the graph value of the torque drop should be reduced.

More on that
Thermal Relay Current Tuning - Xinjie Thermal Relay Current Tuning - Xinjie

(1) What is the current setting value of the thermal relay? The setting current of the thermal relay refers to its action current, that is to say, it is adjusted between 0.95 - 1.05 times of the rated current of the motor being maintained.

An overview of the precise timing instructions of the Seejet PLC An overview of the precise timing instructions of the Seejet PLC

Make accurate punctuality, read accurate punctuality, and stop accurate punctuality. Watchman number. Range: T600 - T618 (T600, T602, T604...) T618, numbered even) Punctuality. Accurate punctuality ...

The wiring of Xinjie inverter complies with the specification The wiring of Xinjie inverter complies with the specification

It is necessary to route the signal line and the power line separately: When using the analog signal remote control inverter, in order to reduce the disturbance of the analog signal of the VFD and other equipment, please separate the signal line of the VFD control from the strong current circuit (main circuit and sequential control circuit). The spacing should be more than 30cm. Even in the control ...

Inverter protection and display function - Xinjie Inverter protection and display function - Xinjie

1. Maintenance of the inverter itself: Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the maintenance of the inverter itself, the overcurrent, overvoltage, undervoltage and so on set the limit value, when the inverter is running, if ...

The operation and use of the physical environment of the inverter - Xinjie The operation and use of the physical environment of the inverter - Xinjie

1. Operating temperature. The inverter is a high-power electronic component, which is easily affected by the operating temperature, and the product is generally required to be 0-55 °C, but in order to ensure the safety and reliability of the operation, it should be considered to leave room for use, and it is best to control it below 40 °C. In the control box, the inverter ...

The Xinjie touch screen screen production system includes the project The Xinjie touch screen screen production system includes the project

The creation of the touch screen screen is done by TouchWin editing tool software. Each screen includes each control menu and video window, and the home page can be written by the relevant units to write the advertising screen welcome speech or system model description. The system mainly includes the following items: ...

The application field of PLC - Xinjie The application field of PLC - Xinjie

At present, PLC has been widely used in various industries such as steel, petroleum, chemical industry, electric power, building materials, machinery manufacturing, cars, textile, transportation, environmental protection and culture and entertainment at home and abroad. 1 ...

The allowable length of the cable between the inverter and the motor - Xinjie The allowable length of the cable between the inverter and the motor - Xinjie

The voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, form the motor winding heating, produce vibration and noise, accelerate the aging of insulation, and even ...

Introduction to the configuration method of inverter - Xinjie inverter Introduction to the configuration method of inverter - Xinjie inverter

1. Acknowledging the characteristics of the load such as load type, speed, and nature; 2. Acknowledging whether it is continuous work, long-term work, short-term work and other work characteristics; 3. Acknowledging the maximum consumption output value and the extra output value; 4. Acknowledging ...

Internal causes and preventive measures of inverter failure Internal causes and preventive measures of inverter failure

The problem of the inverter is not only affected by external factors, but also by internal factors. 1. The inverter parameter setting is unreasonable and countermeasures to make the inverter work normally, in addition to the normal equipment, the parameter setting is also very important, if the parameter is not set properly, it will not be able to ...

Xinjie PLC problems and solutions Xinjie PLC problems and solutions

Xinjie PLC 丨Communication failure is generally summarized as the following problems: (1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent. (2) Communication line: The connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.

Introduction of Xinjie PLC inverter visual system Introduction of Xinjie PLC inverter visual system

XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...

Precautions for PLC circuit debugging - Xinjie Precautions for PLC circuit debugging - Xinjie

1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the situation; The positive logic criterion is usually used, that is, when the input and output are live, it is the "ON" state and the data value is "1"; On the other hand, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...

Advantages and opportunities of domestic PLC - Xinjie Advantages and opportunities of domestic PLC - Xinjie

At present, in the domestic PLC market, there are many kinds, but there are not many domestic PLC manufacturers with real strength, most of the domestic PLC is not an individual who does not have the qualification of a legal person, or a single-chip microcomputer enthusiast, from the domestic PLC factory to buy the underlying programming code or buy a domestic PLC chip (the domestic P that burns the underlying code...

PLC input and output circuit debugging - Xinjie PLC input and output circuit debugging - Xinjie

1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...

Diagram of the wiring of the servo motor of Xinjie Diagram of the wiring of the servo motor of Xinjie

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

The difference between PLC and PAC - Xinjie The difference between PLC and PAC - Xinjie

PLC is the abbreviation of programmable logic manipulator, which is a digital operation manipulator with a microprocessor for automatic control, which can load control instructions into memory at any time for storage and fulfillment. PAC is an abbreviation for Programmable Automation Manipulator. PAC in industrial control ...

Xinjie inverter overload protection object Xinjie inverter overload protection object

Inverters are mainly divided into two categories according to the frequency conversion method: communication/DC/communication and communication/communication inverters. AC/DC/AC inverter, also known as direct inverter, refers to the operation, the first 50Hz power frequency communication power is converted into pulsating direct current through the rectifier module unit, ...

Common problems and solutions of Xinjie PLC Common problems and solutions of Xinjie PLC

1. Why can't the PLC communicate with the peripherals? Communication failures are generally summarized as the following problems: 1. Communication cable: The connection may be incorrect, or the contact is poor, the user can change the communication cable and try again. 2. Communication parameters: PLC communication port and peripheral equipment ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top