1. Operating temperature. The inverter is a high-power electronic component, which is easily affected by the operating temperature, and the product is generally required to be 0-55 °C, but in order to ensure the safety and reliability of the operation, it should be considered to leave room for use, and it is best to control it below 40 °C. In the control box, the inverter should generally be installed on the upper part of the box, and strictly abide by the installation requirements in the product manual, and it is definitely not allowed to install the heating element or the element that is easy to heat up close to the bottom of the inverter.
2. Ambient temperature. When the temperature is too high and the temperature changes greatly, the inverter is prone to condensation, and its insulation function will be greatly reduced, and it may even cause a short circuit. If necessary, a desiccant and a heater must be added to the box.
3. Corrosive gases. If the concentration of corrosive gas in the application environment is large, it will not only corrode the lead wires and printed circuit boards of the components, but also accelerate the aging of plastic equipment and reduce the insulation function.
4. Oscillation and shock. Control cabinets equipped with frequency converters are subjected to mechanical oscillations and shocks, which can cause poor electrical contact. At this time, in addition to improving the mechanical strength of the control cabinet and keeping it away from the oscillation source and impact source, the anti-seismic rubber pad should also be used to fix the external and internal electromagnetic switches of the control cabinet and other oscillating components. After the equipment has been running for a period of time, it should be inspected and maintained.
|
More on that
|
Inverter interference mode and treatment method - Xinjie
Communication:
(1) Radiation disturbance;
(2) Conduction disturbance
Anti-disturbing method: Regarding the disturbance signal transmitted by the radiation method, it is mainly weakened by wiring and shielding the radioactive source and the disturbed line. With regard to the disturbance signal transmitted through the line, ...
|
|
Xinjie launched a professional solution for tapping machines
Tapping machine is a kind of machine tool that uses taps to process internal threads, and it is the most widely used internal thread processing machine tool. The tapping machine avoids the limitations of lathes, drilling machines or manual tapping, and saves time, labor, is not easy to rot teeth, and taps are not easy to break.
|
|
Xinjie PLC cable design selection and construction anti-interference measures
(1) The analog signal is a small signal, which is very susceptible to external interference, and a double-layer shielded cable should be selected;
(2) High-speed pulse signals (such as pulse sensors, digital disks, etc.) should be shielded cables, not only to prevent external interference, but also to prevent high-speed pulse signals from low-power.
|
|
The wiring of Xinjie inverter complies with the specification
It is necessary to route the signal line and the power line separately: When using the analog signal remote control inverter, in order to reduce the disturbance of the analog signal of the VFD and other equipment, please separate the signal line of the VFD control from the strong current circuit (main circuit and sequential control circuit). The spacing should be more than 30cm. Even in the control ...
|
|
On the importance of PLC programming experience
The relevant PLC Fadu Imagination Theory is primary. Without theoretical preparation or allocation in this area, it is easy to deal with brief questions by simply inquiring in practice. It's not easy to mess up. Not only did I have no idea where to start, but it took a lot of time and energy, and it was difficult to compile a high-power, high-quality ...
|
|
PLC input and output circuit debugging - Xinjie
1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...
|
|
PLC control back troubleshooting method - Xinjie
1. PLC input and output
A small PLC controls a complex system with agility, and what can be seen is the upper and lower rows of staggered input and output relay terminals, corresponding lamps and PLC numbers, just like a piece of integrated electricity without dozens of feet. If any ego doesn't look at reason...
|
|
The difference between PLC and single-chip microcomputer - Xinjie PLC
The ladder diagram of the PLC can be understood as a programming language like the assembly and other calculator languages, but the scale of use is different! And the general practice is to convert your ladder diagram into C or assembly language (determined by the CPU used by the PLC), and then use the assembly or C compilation system to compile ...
|
|
Troubleshooting methods for unsuccessful touch screen penetration
A:a. Now only the TGM series touchscreen supports penetration as well as network connectivity
b. At present, the penetration function only supports the PLC class of Xinjie that supports the Xnet protocol, and other models do not support it temporarily
c. Check whether the computer has the latest version of config installed serial port equipment tool (soft ...
|
|
The risk cost of using the inverter - Xinjie
When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents.
Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...
|
|
Advantages and opportunities of domestic PLC - Xinjie PLC
At present, in the domestic PLC market, there are many kinds, but there are not many domestic PLC manufacturers with real strength, most of the domestic PLC is not an individual without legal person qualifications, or a single-chip microcomputer enthusiast, from the domestic PLC factory to buy the underlying programming code or buy a domestic PLC chip (the domestic P ...
|
|
Inverter daily inspection items - Xinjie
(1) Whether there is an abnormal change in the sound during the operation of the motor, including whether there is vibration during the operation of the motor.
(2) Whether the installation environment of the inverter has changed. Whether the ambient temperature is normal, the operating temperature of the inverter is generally required to be in the range of -10 °C - +40 °C, and it is better to take about 25 °C.
|
|
Xinjie inverter control motor method
The Variable-Frequency Drive (VFD) controls the speed and operation of the motor by adjusting the frequency and amplitude of the output voltage. Specifically, the VFD controls the speed of the motor mainly through the following steps:
Collecting Input Signals: VFD First ...
|
|
The range of use of Xinjie general inverter
A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor according to the demand, and then achieve higher output power and power savings. Universal inverters have a wide range of application scales and can be used for various types of electric motors, including communication motors, direct ...
|
|
False load connection method in the debugging of the inverter - Xinjie
There are many novices who are not familiar with the false load about the maintenance inverter, and the maintenance inverter uses the false load to keep many of their modules, because the maintenance novice generally does not know how to do this, and now the electric light is on to clarify that the module is going to be broken. A dummy load is a load with a resistor of several hundred ohms ( ...
|
|
The characteristics of the inverter in the process of development - Xinjie
The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control.
VFDs are power converters in motion control systems. ...
|
|
Inverter overhaul process - Xinjie inverter
1) Investigation and investigation of problem phenomena. There are many kinds of inverter problem phenomena, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same problem phenomenon, which brings difficulties to find the problem. However, the problem phenomenon is the basic basis for overhauling the inverter ...
|
|
Small PLC manufacturers introduce the classification of PLC - Xinjie
Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points.
1. Classified by input/output points
(1) ...
|
|
Precautions when connecting the servo and the PLC
(1) The PLC itself should be grounded according to the specified wiring specifications and grounding conditions, and attention should be paid to prevent the use of common grounding wires with Xinjie servo, and the two should be separated as much as possible when grounding.
(2) When the power supply condition ...
|
|
Xinjie Electric joins hands with Zhongchi Fulian to create a new future of smart industry
On the afternoon of March 20, Wuxi Xinjie Electric Co., Ltd. signed a strategic cooperation agreement with Henan Zhongchi Fulian Seiko Technology Co., Ltd. Li Xin, Chairman of Xinjie Electric, Feng Guangwei, Deputy Director of the Electronic Information Department of the Investment Promotion Bureau of the Airport Pilot Zone, and Liu Guangwei, Executive President of Foxconn Technology Group.
|
|