It is necessary to route the signal line and the power line separately: When using the analog signal remote control inverter, in order to reduce the disturbance of the analog signal of the VFD and other equipment, please separate the signal line of the VFD control from the strong current circuit (main circuit and sequential control circuit). The spacing should be more than 30cm. This cabling standard should be maintained even in the control cabinet. The maximum control loop between this signal and the VFD must not exceed 50m.
It is necessary for the signal cable and the power cable to be placed in different metal pipes or metal hoses: if the signal cable connecting the PLC and VFD is not placed in the metal pipe, it is easy to be disturbed by the VFD and external equipment; Together, because the VFD does not have a built-in reactor, the input and output power lines of the VFD will have a strong disturbance to the outside world, so the metal pipe or metal hose where the signal line is placed should be extended to the control end of the VFD to ensure that the signal line is completely isolated from the power line.
1. The analog control signal line should be double-strand shielded wire, the wire standard is 0.75mm2, and the cable stripping must be as short as possible (about 5-7mm) when wiring, and the shielding layer after stripping together should be wrapped with insulating tape to avoid the shielding wire contacting other equipment and introducing disturbance.
2. In order to improve the simplicity and reliability of wiring, it is recommended to use crimping rod terminals on signal lines.
|
More on that
|
Xinjie Electric joins hands with Zhongchi Fulian to create a new future of smart industry
On the afternoon of March 20, Wuxi Xinjie Electric Co., Ltd. signed a strategic cooperation agreement with Henan Zhongchi Fulian Seiko Technology Co., Ltd. Li Xin, Chairman of Xinjie Electric, Feng Guangwei, Deputy Director of the Electronic Information Department of the Investment Promotion Bureau of the Airport Pilot Zone, and Liu Guangwei, Executive President of Foxconn Technology Group.
|
|
PLC installation precautions - Xinjie
Of course, PLC control is much more reliable than relay control, but if the device does not meet the requirements, it will not work. Therefore, the PLC machine should be installed correctly outside.
(1) Pay attention to the environment of the installation
The temperature should not be lower than 0°C and above 55°C, for example, not installed by a large stove, and ...
|
|
The role of motion control for inverters - Xinjie
Motion control has a significant period characteristic, it is a variety of high-tech generalization, used to bring industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
The reason why the inverter damages the motor bearing - Xinjie
The damage of the inverter to the motor contains two aspects, the damage of the stator winding and the damage of the bearing, this damage usually occurs in a few weeks to more than ten months, the detailed moment and the inverter brand, the motor brand, the motor power, the inverter carrier frequency, the cable length between the inverter and the motor, the ring ...
|
|
The risk cost of using the inverter - Xinjie
When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents.
Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...
|
|
An overview of the precise timing instructions of the Seejet PLC
Make accurate punctuality, read accurate punctuality, and stop accurate punctuality.
Watchman number. Range: T600 - T618 (T600, T602, T604...) T618, numbered even)
Punctuality.
Accurate punctuality ...
|
|
The difference between Xinjie inverter and inverter power supply
What is a frequency converter?
Variable frequency drive (VFD) uses inverter technology and microelectronics to change the operating power frequency of the motor to control the power control unit of the communication motor.
The inverter is mainly composed of rectifier (from communication to DC), inverter, inverter (from DC ...
|
|
Precautions for installation of Xinjie servo motor
The MS series of servo motors can be installed in either the horizontal or vertical direction. However, if it is installed incorrectly, or in an unsuitable place, it can shorten the life of the motor or cause unexpected accidents.
Storage temperature
In the unpowered state ...
|
|
Advantages of using motor soft starter - Xinjie
The motor soft starter is a new type of starting equipment designed and produced by using power electronics skills, microprocessing skills and modern control theory.
The motor soft starter can effectively limit the starting current of the AC asynchronous motor when starting, and can be widely used in wind ...
|
|
The range of use of universal frequency converters
A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor as needed, and then achieve higher production efficiency and power savings. The universal inverter has a wide range of application scales and can be used in various types of motors, including communication motors, direct motors, ...
|
|
The development status of human-computer interface shopping malls in China
The development status of human-computer interface shopping malls in China
China is the shopping mall with the largest demand for human-computer interface in the world, but it is not the shopping mall with the highest sales of human-computer interface products in the world.
|
|
PLC input and output circuit debugging - Xinjie
1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...
|
|
The way the PLC controller works - Xinjie
Although many relays, timers and counters are often used in the ladder diagram programs used by PLCs, PLC does not have these hardware physically, but uses memory and program programming methods to do logic control and editing, and connects external mechanical devices to make physical devices through output components.
|
|
Causes and solutions of inverter leakage - Xinjie
1. The cause of the leakage problem
Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reason for this problem is explained and stated as follows.
Depend on...
|
|
Analysis of problems encountered by Xinjie PLC
Xinjie PLC丨The condition is established, why is the corresponding coil not in place? There are two possible reasons for this:
(1) The same coil may be used in multiple places to perform the double coil output, and the coil on the rear side will operate first when the double coil is output.
(2 ...
|
|
The difference between PLC and PAC - Xinjie
PLC is the abbreviation of programmable logic manipulator, which is a digital operation manipulator with a microprocessor for automatic control, which can load control instructions into memory at any time for storage and fulfillment.
PAC is an abbreviation for Programmable Automation Manipulator. PAC in industrial control ...
|
|
Attention to the solution of heat dissipation in the application of inverter - Xinjie
Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease.
...
|
|
Xinjie inverter control mode
The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the working frequency is 0-400Hz. Its control methods have gone through the following four generations.
1U/f=C Sine Pulse Width Modulation (SPWM) Control Method ...
|
|
Xinjie WIFI communication module WBOX
Product Description:
According to the 2.4GHz Wifi wireless communication module, it has RS232 and RS485 interfaces
Compatible with Xinjie XC2 - XCM series, XD series PLC, MODBUS RTU equipment
The XD-WBOX-ED is connected to the left side of the XD series PLC
Opt IEEE802.11b.g. ...
|
|
The difference between the models of Xinjie TG series touch screen
The suffix is XT and only supports RS232 communication, 4 inches out.
The suffix MT supports RS 232/485/422 communication.
The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk.
The suffix is named ET and is added to the UT ...
|
|