Megmeet PLC – How does PLC communicate with computers?

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. In this computer, right-click, manage, check to find the device manager, plug in the USB-PPI cable (one end is connected to the computer, the other end is connected to the PLC), the computer device manager will pop up the port USB-SERLAL CH304 (com3), the number in parentheses may change, indicating that you have found the cable. This needs to be recognized by the driver first.

2. Open the communication in the step7 programming software project column, then open the setting PG/PC interface, select PC/PPI cable.ppi.1 in its window, select 0 for the attribute address, this address 0 is the computer address, and then select COM3 in the local connection column (there will be changes comx).

3. Click the communication icon, and the communication PLC icon will appear on the right side of the pop-up window, indicating that it is successful, and the remote below is the PLC address.

4. You can verify that the PLC above is turned on at the entry point, the point is running, and the PLC is stopped to see if there is any response.
Megmeet PLC – How does PLC communicate with computers?

More on that
The cause and treatment method of the fault code Eroc1 of Megmeet inverter The cause and treatment method of the fault code Eroc1 of Megmeet inverter

1. Overcurrent fault of inverter Fault Code: OCF. (1) Fault name: inverter overcurrent fault (2) The cause of the failure: the motor nameplate data input is incorrect: the load dragged by the motor is too heavy: the machinery is stuck; Motor stalled. (3) ...

Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter

1. Over-temperature protection of inverter and its necessity The temperature protection function of the inverter is an indispensable condition to ensure the stable operation of the inverter; In the main circuit power device of the inverter, the rectifier bridge and the inverter bridge are semiconductor power devices.

Megmeet PLC – the three output types of PLC Megmeet PLC – the three output types of PLC

The first is relay output, the relay output response speed is slow, the output current is large, generally can reach 2A, but the electric shock life is short, the output frequency is low, the maximum is 1HZ; The second is transistor output, the transistor output response speed is fast, the output current is small, and the contact life is relatively small.

Common faults and solutions of Megmeet PLC Common faults and solutions of Megmeet PLC

1. Do not execute the program: The input check is identified by the input LED indicator or the input monitor composed of a writer. When the input LED is not lit, it can be preliminarily determined that the external input system is faulty, and then check with the multimeter. If the output voltage is not normal, it can be determined that ...

Megmeet inverter maintenance and testing method Megmeet inverter maintenance and testing method

Megmeet inverter maintenance and testing method   1. The Megmeet rectifier module is damaged It is usually caused by grid voltage or internal short circuit. In the case of sweeping internal short circuits, the rectifier bridge is replaced. When dealing with shortcomings on site, the user power grid should be checked. Such as electricity ...

The application of Megmitte industrial control products in high-speed precision CNC machine tools The application of Megmitte industrial control products in high-speed precision CNC machine tools

With the rapid development of the machinery manufacturing industry, the traditional general machine tool can no longer meet the changing parts processing needs of the shopping mall. CNC machine tools have undeniably become the mainstream processing equipment of today's machinery manufacturing. In response to the special application needs of the machine tool industry, Megmeet has launched the MV series of high-function ...

Megmeet PLC - the difference between PLC and frequency converter Megmeet PLC - the difference between PLC and frequency converter

1. The role is different A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment. The inverter is the application of frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor working power supply.

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet MC100 series plc – the right hand man in refrigeration equipment Megmeet MC100 series plc – the right hand man in refrigeration equipment

First, the process requirements When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time. The high pressure collected is greater than that on the high pressure ...

Solutions to common faults of Megmeet inverter (2) Solutions to common faults of Megmeet inverter (2)

Fault three Fault phenomenon: There is a rebound phenomenon when the rotation starts Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5) 2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...

Megmeet drive common fault repair methods Megmeet drive common fault repair methods

When the oscilloscope looks at the current monitoring output of the driver, it is all noisy and cannot be read Cause: The current monitoring output is not blocked from the AC power supply (transformer). Solution: You can use a DC voltmeter to detect and investigate. Servo motor high-speed rotation ...

Megmeet servo drive - common faults and treatment methods of servo drives Megmeet servo drive - common faults and treatment methods of servo drives

1. The motor runs differently in both directions Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position. Solution: Detect or detect the correct phase; Reposition the potentiometer. 2. The motor speed is abnormal Cause of failure ...

Megmeet PLC - how the PLC communicates with the host computer Megmeet PLC - how the PLC communicates with the host computer

The PLC communicates with the host computer, and BlandC is used to write the communication program between the host and the PLC, and the COM1 port must be initialized, the baud rate is 9600bps, and the parity check bit adopts even check, and the seven-digit valid data is used. When the computer receives the response character ACK from the PLC, it ...

Megmeet inverter - the role and application of the inverter control cabinet introduction Megmeet inverter - the role and application of the inverter control cabinet introduction

Inverter control cabinet (inverter electrical control cabinet / electric control cabinet / electric control box) is an electrical control cabinet developed by using inverters from Siemens, ABB, Schneider, Fujifilm, Mitsubishi, Panasonic, Delta, Shilin, Inovance and other manufacturers. According to the needs of working conditions, AC transmission can be installed in the frequency conversion cabinet.

Megmeet drives – routine and regular maintenance of drives Megmeet drives – routine and regular maintenance of drives

1. Maintenance items and scope: Daily maintenance and maintenance of inverter Due to the influence of environmental temperature, humidity, dust and vibration, it will lead to the aging of the internal components of the inverter, resulting in the potential failure of the inverter or reducing the service life of the inverter. Therefore, there is a must ...

Megmeet PLC – the maintenance steps of the PLC control cabinet Megmeet PLC – the maintenance steps of the PLC control cabinet

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

Megmeet drives – a common fault in low-voltage drives Megmeet drives – a common fault in low-voltage drives

External electromagnetic interference can easily cause malfunctions If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...

The principle of Megmeet plasma cutting and its characteristics The principle of Megmeet plasma cutting and its characteristics

5) PLASMA The principle of plasma cutting is: arc discharge between the base metal (including the nozzle in the cutting torch) and the electric in the cutting torch, and use the discharge heat energy to make the compressed gas produce a high-temperature and high-speed plasma arc to fuse the cutting method of the base metal. The small hole of the nozzle ...

Megmeet inverter - what are the control methods of the inverter? Megmeet inverter - what are the control methods of the inverter?

Sinusoidal Pulse Width Modulation (SPWM) control mode It is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of industry. However, this type of control is at low frequencies, ...

Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition Megmeet Electric participated in the 2021 CHINAPLAS World Rubber and Plastics Exhibition

From April 13 to 16, 2021, CHINAPLAS 2021 was grandly held at the Shenzhen World Convention and Exhibition Center (Bao'an New Hall) with the theme of "New Era· New Power, · Sustainable Innovation". As a vane of rubber and plastics professions and a barometer of shopping malls, the World Rubber and Plastics Exhibition has a 350,000 square meter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383