1. Maintain the inverter from the damage of regenerative electricity

If this part of the regenerative energy is not consumed in time, it will directly act on the DC circuit part of the inverter. The presentation of braking resistors deals with this problem very well, and the inverter is not damaged by the regenerative power of the motor.

                               The role of the inverter's braking resistor - LS generates electricity

2. Ensure the smooth operation of the power supply network

The braking resistor directly converts the regenerative electrical energy in the rapid braking process of the motor into thermal energy, so that the regenerative electrical energy will not be reflected in the power supply network and will not cause the voltage fluctuation of the power grid, thus playing a role in ensuring the smooth operation of the power supply network.

The inverter is equipped with a braking resistor, mainly to consume part of the energy on the DC bus capacitor through the braking resistor to prevent the voltage of the capacitor from being too high. Theoretically, if the capacitor stores more energy, it can be used to release it to drive the motor to prevent energy waste, but the capacity of the capacitor is limited, and the withstand voltage of the capacitor is also limited, when the voltage of the bus capacitor is high to a certain extent, the capacitor may be damaged, and some may also damage the IGBT, so it is necessary to release the electricity through the braking resistance in time, this release is wasted in vain, and it is a practice that there is no way.

More on that
After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power

What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized? In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...

Inverter overvoltage fault analysis method - LS power generation Inverter overvoltage fault analysis method - LS power generation

The overvoltage of the inverter is manifested in the tributary voltage of the DC bus. Under normal conditions, the direct current of the inverter is the average value of the three-phase full-wave rectification. If calculated by 380V line voltage, the average DC voltage Ud=1.35U line=513V.

Inverter switching power supply circuit vein - LS power generation Inverter switching power supply circuit vein - LS power generation

1. Vibration circuit: the drainage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels for the working current of the power supply; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

PLC installation and wiring skills - LS power generation PLC installation and wiring skills - LS power generation

The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances. Power cables, control cables, and PLC power cables and I/O cables should be separated from the wiring ...

The working principle of the LS power production module The working principle of the LS power production module

When the LS power generation module is put into operation, its working process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...

Introduction to the output frequency of the inverter - LS power generation Introduction to the output frequency of the inverter - LS power generation

1. Maximum frequency fmax, reference frequency fN and reference voltage UN 2. The upper frequency fH and the lower frequency fL The output frequency of the inverter is limited to the upper and lower limit frequencies to prevent errors in the event of misoperation. 3. Frequency of activation When the signal ON is activated, the ON ...

How LS produces power PLC operation How LS produces power PLC operation

Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.

LS Electric's motion control system solution on pillow (horizontal) packaging machine LS Electric's motion control system solution on pillow (horizontal) packaging machine

The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows: ...

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

Classification of the nature of DC power supply of inverter - LS power generation Classification of the nature of DC power supply of inverter - LS power generation

A frequency converter is actually an inverter. It starts by turning alternating current into direct current. Then the direct current is switched on and off with electronic components. Becomes alternating current. Thyristors for general inverters with larger power. And set up a device with adjustable frequency. Make the frequency adjustable within a certain range. Used to control ...

Electricity-producing permanent magnet AC contactor structure Electricity-producing permanent magnet AC contactor structure

The contactor is mainly composed of a drive system, a contact system, an arc extinguishing system and other parts. 1. Drive system: The drive system includes electronic modules, soft iron, and permanent magnets, which is an important part of the permanent magnet contactor.

How to select the inverter motor - LS produces electricity How to select the inverter motor - LS produces electricity

Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is designed at 50Hz, the frequency of 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque operation, frequency 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power operation, the entire speed regulation scale of (0 ...

Introduction of LS inverter IGXA series Introduction of LS inverter IGXA series

LS inverter, the full name of LS AC inverter governor, converts direct current into alternating current by providing a variety of use configurations, and controls the speed of the motor by changing the voltage and frequency of the general power input to meet different industrial needs, so as to complete the energy saving and environmental protection of the automation system. ...

The working principle of LS PLC module The working principle of LS PLC module

When LS PLC is put into operation, its operation process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the operation, the PLC's CPU repeatedly performs the performance at a certain scanning speed on ...

The reason why the inverter cannot be equipped with a leakage protector The reason why the inverter cannot be equipped with a leakage protector

When using inverters, leakage protectors must not be used. This is a major principle of the use of frequency converters. Some users choose the corresponding leakage protector for the inverter when using the inverter. *The result is: the inverter moves together, the leakage protector acts, and the system can't ...

The five stages of mastery of PLC technology The five stages of mastery of PLC technology

One. Logical stage   The so-called logical stage is to be able to complete the general logical planning in the relay system, since it is a relay system, so the knowledge of power drag is the foundation of this stage. I personally summarize that the root of learning the relay system lies in the word "grab", the relay system ...

Introduction to LS Master-K series PLC programming Introduction to LS Master-K series PLC programming

LS is an electrical equipment company affiliated to LG, kglwin3.62 programming software Chinese version is a professional plc programming software designed to help daily more efficient planning and development software, the software supports the programming and debugging of LG Master-K series and LG MASTER-K series, and provides ...

Elements of LS power inverter operation Elements of LS power inverter operation

1. Physical environment (1) Temperature factor Temperature has a huge impact on the lifetime and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, it is necessary to take additional cooling measures to ensure that the ambient temperature is stable in the inverter.

The principle and function of the power production contactor The principle and function of the power production contactor

The working principle of the power production contact is: when the contact coil is energized, the coil current generates a magnetic field, and the generated magnetic field leads the static iron core to produce electromagnetic attraction to the iron core, and drives the AC contact action, the normally closed contact is disconnected, the normally open contact is closed, and the two are connected to each other. When the coil is de-energized, the electric ...

Introduction of LS electric power contactors Introduction of LS electric power contactors

How LS Contactor Works: Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top