1. The safety wire is blown off
In a general environment, a blown safety wire indicates that there is a problem with the internal wiring of the power supply. Because the power supply is operated in the shape of high voltage and high current, the fluctuation of the grid voltage and the surge city cause the current in the power supply to increase suddenly and cause the safety wire to be blown off. The focus should be on checking the rectifier diode, high-voltage filter electrolytic capacitor, inverter power switch tube, etc. at the input end of the power supply, and check whether the component is broken, open, damaged, etc. If it is indeed a safety wire blow, you should first check the various components on the board to see whether the appearance of these components has been burned, whether there is electrolyte overflow, if the above environment is not found, then use a multimeter to measure whether the switch tube has a breakdown short. The need to pay attention to the following: when a certain component is found to be damaged, it is impossible to start the machine indirectly after conversion, how likely it is that the converted components are damaged because other high-voltage components still have shortcomings, and all the high-voltage components of the above-mentioned electricity must be comprehensively inspected and measured in order to completely eliminate the shortcomings of the safety wire blowing.
2. There is no DC voltage output or the voltage output is not constant
If the safety wire is defective, there is no output of DC voltage at all levels in a load environment. This kind of environment must be composed of the following reasons: the phenomenon of opening and shorting in the power supply, the shortcomings of overvoltage and overcurrent, the shortcomings of the auxiliary power supply, the lack of operation of vibration electricity, the excessive load of the power supply, the breakdown of the rectifier diode in the high-frequency rectification filter electricity, and the leakage of the filter capacitor. If the output is zero when the secondary component is measured with a multimeter and the high-frequency rectifier diode breakdown and the load is short, it must be a defect in the power supply's curtailment. If part of the voltage output declares that the pre-electrical operation is general, the disadvantage lies in the high-frequency rectification filter electricity. The high-frequency filter power must be composed of a rectifier diode and a low-voltage filter capacitor to form a DC voltage output, in which the breakdown of the rectifier diode will cause the electricity to have no voltage output, and the leakage of the filter capacitor will constitute the output voltage instability. Static measurement of the corresponding component with a multimeter can detect damaged components.
3. Poor load capacity of power supply
Poor load capacity of the power supply is a common shortcoming, generally out of the old or long operation time of the power supply, the non-essential reason is the aging of the components, the operation of the switch tube is not the same, there is no timely heat dissipation, etc. It should be focused on checking whether the voltage regulator diode can have fever leakage, rectifier diode damage, high-voltage filter capacitor damage, etc.
|
More on that
|
How to avoid the occurrence of soft failures of the inverter
There are many soft problems in inverters, which are also one of the problems that generally exist in the operation of various types of inverters. So how can we reduce the occurrence of soft problems in inverters? This is a problem that all inverter manufacturers and users are very concerned about. More on that below.
...
|
|
Delixi contactor selection considerations
Electrical safety is not a trivial matter in modern society. Delixi communication contactors are used in homes, public places or commercial buildings. As a power device, its importance is self-evident. If you buy an unsuitable communication contactor, it will appear briefly in the future application process ...
|
|
Delixi product parameter unit VF and V difference
Voltage vf and v difference: The two have different meanings, vf on the battery indicates the feedback voltage, while v represents the capacity of the battery and is a unit of measurement of voltage. Lithium battery is a type of battery that uses lithium metal or lithium alloy as the positive/negative electrode material and uses a non-aqueous electrolyte solution.
...
|
|
Delixi small contactor structure introduction
Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking.
...
|
|
Delixi voltage regulator capacity and size calculation method
1. Single-phase circuit single-phase power supply - power supply with a single AC electromotive force. The fundamental power supply method for civil electricity. Single-phase load – A load that is powered by a single-phase power supply. Household appliances such as lights, televisions, and electric fans are generally single-phase loads. The accounting method is as follows:
a. When negative ...
|
|
Delixi voltage regulator fault phenomenon and analysis
Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis
1. The contact pressure between the carbon brush and the coil plane is too small
2. The carbon brush is severely worn
Delixi voltage regulator has ...
|
|
Delixi integrated voltage regulator knowledge
The role of a voltage regulator is to convert an unstable DC voltage into a stable DC voltage. The integrated voltage regulator has a wider and wider range of applications due to its advantages such as small size, good voltage regulation performance and perfect maintenance function. There are two types of integrated voltage regulators: linear power supply regulators and switching power supply regulators.
|
|
Delixi DZ47LE C40 air switch introduction
The general leakage circuit breaker is wired using the principle of outgoing wire under the progressive line, only need to distinguish the phase line and the zero line, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same.
Delixi DZ47LE C40 ...
|
|
Delixi single-phase inverter CDI-EM60 series manual
Read this statement carefully before installing, operating, maintaining, and viewing the EM60 series drives.
In order to ensure the safety of your person, equipment and property, please be sure to read carefully before using our EM60 series inverter.
|
|
Delixi anti-leakage is different from ordinary circuit breakers
Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time.
Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...
|
|
LDO low dropout linear regulator features - Delixi
Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...
|
|
Delixi parameter voltage regulator performance and advantages
1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...
|
|
Delixi inverter start, stop how to wiring
The control of the inverter is nothing more than the basic logic of starting, aborting, forward rotation, rotation, and speed regulation, which basically requires that the level condition is useful, not the rising margin is useful, so the use of button switches to control the inverter is generally required to use the button in the form of self-protection ...
|
|
Problems in the installation and use of Delixi voltage regulator
What is the voltage regulator can not be connected in parallel, the voltage regulator is not open for a long time, what will be the problem with the voltage regulator still open under normal voltage, is it said that the voltage regulator and the undervoltage lamp is not lit to clarify that the voltage regulator is normal?
Will a normally open regulator burn it out at normal voltage?
...
|
|
Technical parameters of surge protective device - Delixi
Look at the quality of the surge protector, to see whether it can complete the fundamental specification for him, the primary specification related to the surge protector is whether the surge operating voltage can be limited to the required value below, the surge protector in the completion of this mission when it is necessary to discharge the lightning current, this specification is necessary to completely ...
|
|
Delixi leakage circuit breaker identification method
1. Appearance
Genuine Delixi switch shape is more fashionable, looks elegant and beautiful, and the surface is neat, impact resistance is relatively strong, will not briefly crack or yellow.
And most imitations will turn yellow after a period of use...
|
|
The scope of use of Delixi universal inverter
A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor according to the needs and achieve higher production efficiency and energy savings. The general-purpose inverter has a wide range of application scales and can be used for various types of motors, including communication motors, direct motors, ...
|
|
Delixi resistance quantifies the resistance exerted by the circuit to the flow of current
We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). Regarding metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal.
...
|
|
The material of the transformer - Delixi
In view of the regulation and control effect of the transformer in the power system, technicians need to choose the appropriate transformer finishing device operation, so as to play a normal effect. Winding data is the primary problem that transformer devices need to pay attention to, and the effects of devices of different materials are different. Concerning...
|
|
Why use optocouplers in circuits - Delixi
Requirements for electrical barriers. Between A and B circuits, signal transmission is required, but because of the disparity between the power supply levels of the two circuits, one is hundreds of volts, and the other is only a few volts; Two very different power supply systems, unable to share the power supply;
...
|
|