The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. When the shunt tripper receives an external signal, the tripper pushes the rod action to push the tripping equipment of the circuit breaker, so that the circuit breaker trips and opens, so as to disconnect the power supply. The shunt tripper is classified according to the device type, which can be divided into two types: built-in and external.
The built-in type is installed inside the switch when leaving the factory, and the user can not disassemble it by himself, such as Delixi Electric CDM1 plastic shell circuit breaker. Since the cover cannot be removed, the excitter tripper is now installed inside the circuit breaker at the factory. This circuit breaker can not only be equipped with a shunt tripper, but also with an undervoltage tripper, auxiliary contacts, and alarm contacts. Generally, this circuit breaker can be optionally equipped with two accessories.
External, often used in the circuit breaker between the middle cover and the face cover, the user can require the product to be installed at the factory, or can be purchased separately and installed into the circuit breaker by itself. CDM3v plastic shell circuit breaker as one of the latest Dengfeng series products launched by Delixi Electric Electric, it is based on the classic leader channel of Delixi Electric - CDM3 series, a new generation of products, it has 63, 100, 125, 160, 250, 400, 630, 800, 1600 a total of 9 shell frames for customers to choose, the current from the minimum 10A to the maximum 1600A comprehensive coverage. Its new structural design makes the product more reliable and cost-effective. At the same time, it also provides customers with a wider selection of accessories. Shunt tripping, alarm contact, auxiliary contact, undervoltage contact, auxiliary reporting assistant, leakage alarm tripping accessory, overload alarm non-tripping accessory (this accessory is built-in, the user cannot install it by himself). The CDM3v series adopts a double-sided cover design, and users can purchase accessories separately according to their needs, and install them into the circuit breaker by themselves, which is simple to operate and reliable to use. It fully embodies the value of "customer first".
Common shunt tripper, insulation voltage AC400V; Additional impulse withstand voltage: 4KV, additional control voltage, general communication at 50/60HZ AC230V; AC400V。 DC DC24V; DC110V; DC220V。 So how should the wiring be under the additional control voltage.
We get the switch with a split excited tripper, first find the label with the voltage identification, generally the DC shunt trip is not divided into positive and negative poles; Communicate the tripper, and there is no need to distinguish between the front and the neutral line.
Because it is a remote control accessory for users, users are required to select a control switch by themselves, and users can choose to control 1-pole or 2-pole switches (2-pole is recommended). The wiring connection can be carried out as follows.
|
More on that
|
Delixi selection of wire points
When buying wires, the first thing to look at is two aspects: conductors and insulation.
1. Conductors
1. Color
High-quality copper is called "red copper" or "red copper" - the color of this copper is red, purple, and purple-red.
The worse the copper ...
|
|
How to avoid the occurrence of soft failures of the inverter
There are many soft problems in inverters, which are also one of the problems that generally exist in the operation of various types of inverters. So how can we reduce the occurrence of soft problems in inverters? This is a problem that all inverter manufacturers and users are very concerned about. More on that below.
...
|
|
The difference between Delixi LDO and DC-DC
The so-called DC-DC is actually DC to DC voltage, of course, LDO is also a kind of DC-DC, and only LDO can only achieve step-down.
The general DC-DC is mainly converted from DC to AC communication through the self-excited vibration circuit inside, so the external inductance and capacitor are required to achieve LC vibration (and LDO is only ...
|
|
The general principle of circuit breaker selection - Delixi
(1) The additional operating voltage of the circuit breaker ≥ the additional voltage of the line.
(2) The additional current of the circuit breaker ≥ the line load current.
(3) The additional short-circuit of the circuit breaker can be turned on and off to ≥ the maximum shortness that may be present in the line.
|
|
Delixi indicator light failure and solutions
1. What should I do if the indicator light is on and when it is dark
Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire. ...
|
|
The role of Delixi AC voltage regulator
Delixi high-precision fully active AC voltage regulator uses linear integrated circuits to form a control system, controls the servo motor, drives the contact voltage regulator to actively regulate the voltage, and is equipped with delay, overvoltage, undervoltage and overcurrent maintenance functions. The product has high efficiency, the same input and output voltage waveforms, and the output ...
|
|
Delixi voltage regulator boot voltmeter does not indicate fault analysis and solutions
When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem phenomenon and cause analysis
1. The plug is not plugged in firmly, and there is no output voltage
2. The fuse is broken
When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem is solved ...
|
|
Delixi inverter application case
The traditional textile printing and dyeing industry is a labor-intensive industry, and the degree of automation is not high. Most of the transmissions used are not speed regulation, and most of the occasions that need speed regulation are DC motors, such as warping machines, sizing machines and many printing and dyeing equipment.
|
|
The difference between Delixi high-voltage circuit breaker and disconnector
The high-voltage circuit breaker (or high-voltage switch) is the primary power control equipment of the substation, which has arc extinguishing characteristics. When the system is in normal operation, it can intercept and connect the no-load and load currents of lines and various electrical equipment. When there is a problem in the system, it can quickly block the fault with the cooperation of relay maintenance.
|
|
Delixi uses three-phase regulators need precautions
1. If the fuse is burned out, please approve the load equipment as soon as possible, make repairs in time, and restore power;
2. If you use a fixed amount of fuse, please use a regular line, and do not match it at will, so as not to cause ...
|
|
Delixi solid state relay relative to AC contactor characteristics
Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose?
1. First of all, the solid ...
|
|
Delixi DZ47LE C40 air switch introduction
The general leakage circuit breaker is wired using the principle of outgoing wire under the progressive line, only need to distinguish the phase line and the zero line, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same.
Delixi DZ47LE C40 ...
|
|
Delixi inverter parameter setting method
P0.00: Set to G type (constant torque load type).
P0.01: Set to 1 fundamental efficacy model.
P0.02: Set to 1V/F control.
P0.03: Set to 0 keyboard control.
P0.04: Set to be given by the external terminal for multi-segment commands.
...
|
|
Delixi 2P circuit breaker selection introduction
When selecting Delixi 2P circuit breaker, the need is selected according to the additional voltage, additional current and operating environment of the practice circuit. The following are the main series of Delixi 2P circuit breaker and its application scenarios:
DZ47s-63 2p Small ...
|
|
Delixi solid state relay introduction
What is a Solid State Relay
Solid State Relay (SSR) is a pointless switch composed of microelectronic circuits, discrete electronic devices, and power electronic power devices. The barrier between the control end and the load is completed by a barrier device. The input of the solid state relay is micro...
|
|
Delixi frequency converter E series precautions
1. Before the inverter device is in place and debugged, please tighten the components, especially the connecting bolts of the wire part, if not tightened, the connection will be heated and cause fire.
2. The on-site planning of the installation should be reasonable, and the excellent ventilation environment should be maintained.
3. The incoming and outgoing power lines of the inverter are not ...
|
|
The difference between an isolation switch and a circuit breaker
The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position.
Isolate ...
|
|
Delixi inverter in the die-casting machine frequency conversion energy-saving transformation
First, the principle of energy saving
The die-casting machine is a typical periodic variable load equipment, and a complete production cycle includes the stages of mold clamping, injection, cooling, and mold opening and ejection. Usually the power of hydraulic equipment is supplied by a quantitative oil pump, and the motor that drives the oil pump to work has always been rated for its ...
|
|
Parameters of Delixi inverter speed controller
(1) Gain Parameter: The share gain of the speed manipulator. If the gain is too large, it may cause the speed to fluctuate.
(2) Integration time parameter: the integration time of the velocity manipulator, that is, the deviation step signal ...
|
|
The five provinces of the "Strong Foundation Plan" take the lead in building a win-win ecology
Channel business is the foundation of Delixi electric business. Only by clearing the source and stabilizing the foundation can we flourish and build an evergreen foundation! Continuously improving and deepening the order management of shopping malls is the central strategic direction for the company to achieve continuous, healthy and high-speed development together with its distribution partners. For the maintenance of ...
|
|