1. Soft starter
What is the meaning of the Siemens 3RW soft starter order number?
  2. Equipment type (series classification): 3RW30, 3RW40, 3RW44

3. Size/Rated Operating Current IE (40°C, Class 10):

The rated working current range of 3RW30 is 3.6A-106A, the rated working current range of 3RW40 is 12.5A-432A, and the rated working current range of 3RW44 is 29-1214A

4. Link terminal type: This terminal type generally refers to the wiring of the control loop.

3RW30 and 3RW402-404 1 represents the screw terminal and 2 represents the cage card terminal. Among them, the wiring of the main circuit of S00 and S0 specifications is the same as that of the control circuit, and the main circuit of S2 and above specifications are all screw wiring.

3RW405-407 2 represents the cage card terminal, 6 represents the screw terminal, and its main circuit wiring is copper bar wiring.

3RW442 1 represents the screw terminal, 2 represents the cage card terminal, and its main circuit is screw wiring.

3RW443-446 2 represents the cage card terminal, 6 represents the screw terminal, and its main circuit is copper bar wiring.

5. Soft starter function: BB is a built-in bypass contactor, two-phase thyristor control (3RW30 and 3RW40 are optional). BT is a built-in bypass contactor, two-phase thyristor control, integrated motor overheating protection (can detect the embedded thermistor on the motor, only the control voltage is AC/DC 24V, 3RW402-404 can choose this function). BC is a built-in bypass contactor, three-phase thyristor control (3RW44 optional).

6. Rated control power supply voltage Us: refers to the voltage that controls the soft starter (power supply voltage)

7. Rated operating voltage UE: Refers to the main circuit voltage

3RW30 is 200V-480V (order number 4)

The 3RW402-404 is available in 200V-480V (order no. 4) and 400V-600V (order no. 5).

3RW405-407 is available in 200V-460V (order no. 4) and 400V-600V (order no. 5).

The 3RW44 is available in 200V-460V (order no. 4), 400V-600V (order no. 5) and 400-690V (order no. 6).

More on that
Siemens joins hands with Jingyuntong to promote the high-quality development of the photovoltaic industry Siemens joins hands with Jingyuntong to promote the high-quality development of the photovoltaic industry

Siemens and Beijing Jingyuntong Technology Co., Ltd. ("Jingyuntong") recently signed a strategic cooperation agreement. Based on Siemens' advanced automation and digital solutions, the two sides will open up cooperation in the development and production of high-end photovoltaic equipment, and jointly promote the high-tech development of the new energy photovoltaic industry.

Siemens joins hands with Sanning: Ensuring safe production and contributing to green chemical industry Siemens joins hands with Sanning: Ensuring safe production and contributing to green chemical industry

The industrial site of Sanning Chemical Co., Ltd. (Sanning Chemical) is simply unattended, and the production meets various national environmental protection goals, and the park is as beautiful as a garden, and the company's vision is written on the tower, "to build a beautiful chemical industry, to build a century-old Sanning".   Back in 2017, ...

Siemens s7-200 SMART interrupt command Siemens s7-200 SMART interrupt command

The S7-200 SMART series of programmable controllers has up to 38 interrupt sources (9 reserved), which are divided into three categories: communication interrupts, input/output (I/O) interrupts, and time-based interrupts.

Siemens S7-1200 CPU FAQ solved Siemens S7-1200 CPU FAQ solved

Can the 5 VDC power supply provided by the CPU be scaled with an external power supply? A: No, select the appropriate CPU based on the template 5 VDC power usage. Can I use an external power supply when the 24 VDC power supply provided by the CPU is not enough? A: Yes, ...

Siemens S7-200 SMART Common questions about serial communication Siemens S7-200 SMART Common questions about serial communication

1.Does the S7-200 SMART support Modbus ASCII communication mode? The STEP 7-Micro/WIN SMART software does not provide a library of Modbus ASCII communication modes. If the S7-200 SMART CPU is used for Modbus ASCII communication, it needs to be used by the user to use the free port communication.

Common problems with the S7-200 SMART high-speed counter Common problems with the S7-200 SMART high-speed counter

Why does assigning initial and preset values to a high-speed counter not work, or the effect is unexpected? The high-speed counter can be initialized or changed during operation, such as initial values and preset values. The procedure should be: Set update options for control bytes. Need...

Siemens joins hands with Hisense to explore the home appliance industry Siemens joins hands with Hisense to explore the home appliance industry

Siemens recently signed a strategic cooperation agreement with Hisense Group Holding Co., Ltd. (Hisense). The two sides will be based on Siemens' preemptive digital business portfolio, as well as the successful practice of digital transformation, to promote Hisense's digital construction together, and explore the development of intelligent production in the home appliance industry.

Siemens 3RM Motor Starter - Safety Integrity Level for ATEX Explosion Protection Applications Siemens 3RM Motor Starter - Safety Integrity Level for ATEX Explosion Protection Applications

The 3RM11/3RM13 motor starters include two different protection functions. One protection function is a safety application, and the other is an explosion protection application (ATEX). 1. Functional Safety: Here, the purpose of protection is to identify and control dangerous conditions. In the safe ...

Siemens Intelligent Power Distribution won the "Samsung Supplier" of the 2022 Supplier Composite Index SCI Siemens Intelligent Power Distribution won the "Samsung Supplier" of the 2022 Supplier Composite Index SCI

On July 5th, the 8th Global Shenzhen Business Conference and Mining and Construction Consortium Conference was successfully held in Shenzhen, and the results of the 2022 Supplier Induction Index SCI evaluation were released on the spot.

Siemens SIMATIC S7-1200 PLC hardware composition and its characteristics Siemens SIMATIC S7-1200 PLC hardware composition and its characteristics

SIMATIC S7-1200 PLC The S7-1200 series is a Programmable Logic Controller (PLC) that can control a wide range of automation applications. The S7-1200 has a compact design, low cost, and a powerful instruction set.

Siemens introduces a new generation of industrial Ethernet switches Siemens introduces a new generation of industrial Ethernet switches

At SPS 2022 in Nuremberg, Siemens introduced the new generation of Scalance XC-/XR-300 series Industrial Ethernet switches. With the increasing number of machines, controls and IT systems connected to the network in industrial production, the network at the production level is also ...

Siemens S7-200 SMART Power Requirements & Calculations Siemens S7-200 SMART Power Requirements & Calculations

The S7-200 SMART CPU module offers 5VDC and 24VDC power supplies: The CPU has an internal power supply that is used to power the CPU, expansion modules, signal boards, and other 24 VDC user power needs. Use the following information as a guide to determine how much the CPU can provide for the configuration ...

Siemens acquires Brightly Software to accelerate its development in the field of smart buildings Siemens acquires Brightly Software to accelerate its development in the field of smart buildings

Siemens Intelligent Infrastructure recently announced that it has signed an agreement to acquire Brightly Software, a SaaS provider of asset and protection management solutions in United States. The acquisition will strengthen Siemens Intelligent Infrastructure's position in the building and infrastructure software segment. Harvest...

Features of the Siemens S7-1200 memory card Features of the Siemens S7-1200 memory card

The memory card used by the S7-1200 CPU is an SD card, which can store user project files and has the following three functions: As a mount store for the CPU, user project files can be stored only on the card, without project files in the CPU, they cannot run without the memory card. ...

Siemens acquires a minority stake in WiTricity Siemens acquires a minority stake in WiTricity

Siemens invested $25 million to acquire a minority stake in WiTricity, a United States wireless charging technology company. Siemens and WiTricity will work together to promote the innovation of new shopping malls for wireless electric car charging, according to Siemens' calculations, by 2028, only in Europe and North America, which ...

Siemens presents the new Sinamics G220 high-performance inverter Siemens presents the new Sinamics G220 high-performance inverter

On the eve of the Hannover Messe 2023, Siemens launched a new product in the Sinamics series, the Sinamics G220 high-performance frequency inverter. This innovative inverter product uses clean converter technology to reduce harmonics by up to 97% without the need for incoming filters or incoming reactors.   ...

Siemens has released version 4.0 of the web-based SIMATIC PCS neo control system Siemens has released version 4.0 of the web-based SIMATIC PCS neo control system

Process industrial companies are faced with multiple challenges: how to accelerate digitalization, achieve sustainable development, and how to deal with the shortage of skilled personnel. At Siemens, we believe that plant managers can only cope with these challenges and prepare for the future with a highly sensitive process control system. In this cloth ...

Functions of the Siemens 3RV2 circuit breaker Functions of the Siemens 3RV2 circuit breaker

The 3RV2 circuit breakers are available with screw, spring-loaded or ring terminals, giving you the flexibility to choose the right wiring type for your application. Installation The 3RV2 circuit breaker can be snapped on a standard 35 mm rail. S00 and S0 sizes are available with 3RV29 28-0B ...

Upload user files to a Siemens memory card Upload user files to a Siemens memory card

Upload user files to the memory card   Step 1: Follow the above method to set the memory card to "Program Card" mode. Customers are advised to clear all files from the memory card before doing this. Step 2: Set the boot state of the CPU. Right-click the CPU in the Project Tree and select ...

Siemens loads the item to a memory card in transfer mode Siemens loads the item to a memory card in transfer mode

Mount items to a memory card in transfer mode Step 1: Follow the above method to set the memory card to "Transfer Card" mode. Customers are advised to clear all files from the memory card before doing this. Step 2: Set the boot state of the CPU: In the "Project ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top