Siemens S7-1200 PLC basic functions
1. S7-1200 CPU real-time clock hold time
20 days typical, 12 days minimum at 40°C (maintenance-free supercapacitors);
With the BB1297 battery plate and CR1025 battery, the real-time clock power off hold time is approximately 1 year.
2. S7-1200 CP ...
|
|
Siemens 3RM Motor Starter - Safety Integrity Level for ATEX Explosion Protection Applications
Questions:
Why do the 3RM11/3RM13 motor starters have a safety class of SIL2 for ATEX protection and SIL3 and PLe for functional safety applications?
Answer:
The 3RM11/3RM13 motor starters include two different protections ...
|
|
Siemens' path to the world's first native digital factory
Siemens CNC (Nanjing) Co., Ltd. (SNC) officially opened its new factory. This is Siemens' first fully integrated native digital factory in the world, and it is also an excellent "answer sheet" written by Siemens for the "professional examination" of building a digital factory.
1996 ...
|
|
Siemens' intelligent manufacturing engineering talent certification system was officially released
Siemens recently officially launched the Intelligent Manufacturing Engineering Talent Certification System, and the first batch of 12 campuses were certified. Siemens combines its advanced intelligent manufacturing skills with practical experience in the field of engineering education to organize the central digital talents required for modern industrial systems.
|
|
Siemens and Heyouxun have reached a cooperative relationship
Siemens and Hilscher Gesellschaft für Systemautomation mbH, a provider of industrial communication solutions, have teamed up to provide industrial companies with a wide range of sensitive communication protocols.
After integrating the cifX PC card skills of Heyouxun into the western ...
|
|
How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings
You can reset your S7-1200 to factory settings using an empty SIMATIC MC memory card.
illustrate
Even if you don't have SIMATIC STEP 7 Basic software and don't know the IP address, you can use the SIMATIC MC memory card to delete the IP address and put the S7-1 ...
|
|
Functions of the Siemens 3RV2 circuit breaker
The 3RV2 circuit breakers are available with screw, spring-loaded or ring terminals, giving you the flexibility to choose the right wiring type for your application.
Installation
The 3RV2 circuit breaker can be snapped on a standard 35 mm rail.
S00 and S0 sizes are available with 3RV29 28-0B ...
|
|
Siemens S7-200 SMART Analog FAQ
1. Can the S7-200 SMART Normal Analog Module connect 4-20mA signals?
Yes, the S7-200 SMART CPU analog module can detect standard current signals from 0 to 20 mA and 4 to 20 mA. Wiring of two current signals, in the STEP 7-Micro/WIN SMART ...
|
|
Siemens and New Hope work together to create new opportunities
At present, digital technology is empowering the transformation and upgrading of traditional agriculture, animal husbandry and food industries. The use of innovative technologies such as artificial intelligence, big data analysis and cloud accounting has brought the modernization and intelligence of industry to a further step.
As a well-known enterprise in China, New Expectation Group Co., Ltd. ( ...
|
|
Siemens joins hands with Hisense to explore the home appliance industry
Siemens recently signed a strategic cooperation agreement with Hisense Group Holding Co., Ltd. (Hisense). The two sides will be based on Siemens' preemptive digital business portfolio, as well as the successful practice of digital transformation, to promote Hisense's digital construction together, and explore the development of intelligent production in the home appliance industry.
|
|
Precautions for the use of Siemens frequency converters
1. The outlet side of the Siemens inverter can not be connected in parallel to compensate the capacitor, nor can the capacitor be paralleled in order to reduce the high-order harmonics of the output voltage of the inverter, otherwise it may damage the Siemens inverter in order to reduce the harmonics. Able to connect reactors in series.
2. Use Siemens inverter (V...
|
|
Siemens 3RV2 circuit breaker application
The 3RV2 circuit breaker is a compact current-limiting motor start-up protection circuit breaker for the opening and closing of three-phase induction motors (up to 55 kW at 400 V AC) and other loads (rated up to 100 A).
The 3RV2 circuit breaker is suitable for any kind of climate ...
|
|
How to use the data block of the Siemens S7-200 SMART
How to use the data block of Siemens S7-200 SMART. Before explaining the use of data blocks, let's take a look at what data blocks are: data blocks are used to assign initial values to the V store, also called the variable store; Ability to assign data values to bytes, words, or two words.
Divide the data in a chunk ...
|
|
Siemens supports the transition to sustainable infrastructure with new digital solutions
Siemens unveiled its face at the 2022 Lighting and Construction Electrical Exhibition in Frankfurt, Germany under the theme of "Smart Infrastructure Can Continue Infrastructure". During the exhibition, Siemens Essentials underlined its digital vision as the infrastructure needed to address climate change and global sustainability challenges.
|
|
Siemens 3RW44 motor rated current and CLASS class setting
3RW44 soft starter, when the rated current setting of the motor is inconsistent with the CLASS level, the soft starter will have a fault alarm. Since the 3RW44 has 3 sets of parameter settings, the 3 sets of parameters can be set with different current ratings. However, the CLASS level is set in the "Motor Protection" option, and can only be set ...
|
|
Siemens PLC has six common fault-prone points
1. The first type of fault point is also the location of the most faults in relays and contactors
For example, in the daily maintenance of the PLC control system of a production line, the largest consumption of electrical spare parts is all kinds of relays or air switches. In addition to the quality of the product itself, it is mainly due to the fact that the on-site environment is more ...
|
|
Siemens released its third-quarter financial results
Siemens, as a dedicated technology company, delivered significant results in the third quarter of fiscal 2022 (ended June 30, 2022). The macroeconomic environment remains chaotic due to factors such as economic sanctions against Russia, high inflation and the coronavirus pandemic, but Siemens is still in many key malls.
|
|
What are the features of the memory card used by the Siemens S7-1200 CPU
The memory card used by the S7-1200CPU is an SD card, which can store user project files, and has the following main functions:
1. As the loading storage area of the CPU, the user project files can only be stored in the card, there are no project files in the CPU, and they cannot be run without the memory card.
...
|
|
Siemens acquires Brightly Software to accelerate its development in the field of smart buildings
Siemens Intelligent Infrastructure recently announced that it has signed an agreement to acquire Brightly Software, a SaaS provider of asset and protection management solutions in United States. The acquisition will strengthen Siemens Intelligent Infrastructure's position in the building and infrastructure software segment. Harvest...
|
|
Siemens launches the new SITOP PSU2200 economical rail power supply
Siemens expands its power supply portfolio with the launch of the new SITOP PSU2200 economical rail power supply. The new product can be divided into three models according to the output current: 3A, 5A and 10A, which can convert AC 220V to DC 24V to meet the fundamental needs of industrial power supply. SITOP PSU2200 ...
|